HomeMy WebLinkAboutPZ INSPECTION TICKET 1 - 19-00359 - 871 Jet Stream Dr - The Rock Gym - New CommercialInspection
Ticket
Planning and Zoning Review - Site Plan on 06/28/2019:
Permit Number: 19-00359Permit Details
Building - Commercial
Permit Issued Date:
Permit Issued Date: Final Inspections Required
Fire Sprinkler Final Inspection HVAC Final Inspection
Plumbing Final Inspection Fire Department Final Inspection
Public Works Final Inspection Fire Alarm Final Inspection
Planning and Zoning Final Inspection Commercial Electrical Final Inspection
Commercial Building Final
871 Jet Stream Dr
871 Jet Stream Dr - The Rock Gym - New Commercial
Inspection Details
tawnya.grover@rexburg.org
Inspected By: Quinton Owens
Planning and Zoning Review - Site Plan on 06/28/2019:
D ESCRIPTIO N CO M M EN TS STATUS
Plans are approved for a footing/foundation
ONLY permit?
YES
No utility boxes in right of way?Utility boxes are not shown.REVISIONS
Do parking stalls meet code requirements?
(Sizes & number of stalls/doors or beds?
Parking spaces on east side of building are only
15 ft in length. The only reduction allowed is for
compact vehicles for which the minimum length
is 16 ft and they must be designated for
compact vehicles. (Dev. Code 3.04.120.a.1.c)
REVISIONS
Are utilities fenced or screened from view?VERIFY IF APPLIES TO LIGHT INDUSTRIAL.
Submit landscaping plan showing screening for
parking per 3.04.040.e
REVISIONS
Are the landscaping requirements met? (# of
trees, caliper of trees, etc.)
Are green space percentage requirements met?
Submit landscaping plan showing required
buffering for Highway 20 per Dev. Code
3.02.100.e
REVISIONS
Does parking lot design meet building code
requirements?
(Drive aisles, entrances & exits)
Maneuvering areas shall not be provided within
a required front yard (Dev. Code 3.04.040.b).
The maneuvering space for parking by north
entrance overlaps the front setback.
REVISIONS
Unloading, loading area Overhead door near entrance: Be sure
maneuvering for loading/unloading will not use
the right-of-way (not allowed)
APPROVED
Parking space number 4 stalls/1000 sf x 10800 sf = 43 parking stalls
required. 62 stalls are provided
APPROVED
Does the building height match the setback
requirements for the zone?
Tallest wall is 44 feet.APPROVED