Loading...
HomeMy WebLinkAboutBUILDING CODE DATA - 19-00359 - 871 Jet Stream Dr - The Rock Gym - New CommercialBuilding Code Data Use and Occupancy Classification (Chapter 3) Group A-3 Construction Type (Table 601) Type V-B Allowable Height and Area (Chapter 5) Allowable Building Height Above Grade (Table 504.3) Height = 40 Feet (Type V-B, NS) Allowable Number of Stories Above Grade (Table 504.4) Story = 1 Story (Type V-B, NS) Allowable Area Factor (Table 506.2) 6,000 sqft (Type V-B, NS) Amount of Increase (Sec. 506.3.3) Frontage Increase = [F/P - 0.25] w/30 Building = .49 x 6,000 = 2,969 + 6,000 = 8,969 sf Actual Area Main Level = 8,816 sf Main Level = 13,039 sf Mezzanine = 1,916 sf 2nd Level = 13,279 sf Total = 10,732 sf Fire Resistance Rating Requirements for Building Elements Elements Min. Fire Resistance Primary Structural Frame 0 hr. Table 601 Bearing Walls (Exterior/Interior) 0 hr. Table 601 Nonbearing Walls – Interior 0 hr. Table 601 Floor/Secondary Structure 0 hr. Table 601 Roof Construction 0 hr. Table 601 Occupancy Load and Exit Requirements Occupant Load Calculations (Table 1004.1) Main Level = 176.32 (exercise) Mezzanine Level = 36.32 9 (exercise) Exit Access Travel Distance (Table 1017.2) Group A-3 Non sprinkler = 200 feet