HomeMy WebLinkAboutBUILDING CODE DATA - 19-00359 - 871 Jet Stream Dr - The Rock Gym - New CommercialBuilding Code Data
Use and Occupancy Classification (Chapter 3)
Group A-3
Construction Type (Table 601)
Type V-B
Allowable Height and Area (Chapter 5)
Allowable Building Height Above Grade (Table 504.3)
Height = 40 Feet (Type V-B, NS)
Allowable Number of Stories Above Grade (Table 504.4)
Story = 1 Story (Type V-B, NS)
Allowable Area Factor (Table 506.2)
6,000 sqft (Type V-B, NS)
Amount of Increase (Sec. 506.3.3)
Frontage Increase = [F/P - 0.25] w/30
Building = .49 x 6,000 = 2,969 + 6,000 = 8,969 sf
Actual Area
Main Level = 8,816 sf
Main Level = 13,039 sf
Mezzanine = 1,916 sf
2nd Level = 13,279 sf
Total = 10,732 sf
Fire Resistance Rating Requirements for Building Elements
Elements
Min. Fire Resistance
Primary Structural Frame 0 hr.
Table 601
Bearing Walls (Exterior/Interior) 0 hr.
Table 601
Nonbearing Walls – Interior 0 hr.
Table 601
Floor/Secondary Structure 0 hr.
Table 601
Roof Construction 0 hr.
Table 601
Occupancy Load and Exit Requirements
Occupant Load Calculations (Table 1004.1)
Main Level = 176.32 (exercise)
Mezzanine Level = 36.32 9 (exercise)
Exit Access Travel Distance (Table 1017.2)
Group A-3 Non sprinkler = 200 feet