Permit Status of (Open) as of Report Date: 07/15/2019 11:19 am
Permit Details Permit Number: 13-00435
860 Oak Hill Circle - SFR
860 Oak Hill Circle
Building - Single Family Residence
Permit Issued Date: 12/03/2013
Permit Inspection Statistics
23Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 69.57%
Permit Inspection History *Refer to Individual Inspection Report for more Details
12/13/2013PassTed DyeFooting Inspection
01/31/2014PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-inspected the electrical service
on the rough-in inspection.
Inspector Comments:
07/21/2014PassTed DyeFoundation Inspection
Building Inspection Type
01/15/2014FailQuinton OwensSheeting
1/3, QO: Seismic hold down in NW corner by Liv. rm window is not nailed to
double stud. Finish nailing all holes in hold down straps. Some nailing missed
(some missed/some spaced to far apart - staples should be 2" to 4").
1/15: Not done yet
Inspector Comments:
02/08/2014PassTed DyeInsulation Inspection
Door off of kitchen dining needs insulation on left side near top.Inspector Comments:
02/10/2014PassTed DyeSheetrock/Drywall Inspection
Tempered window required above tub. Finish attic access. Anchor bolts missing
in basement bearing walls (6' oc max). Egress ladder in at least one window well.
Grading to slope away from house.
Inspector Comments:
04/25/2014FailQuinton OwensBuilding Final
Back steps and landing approved only as temporary.Inspector Comments:
07/15/2014PassTed DyeBuilding Final
07/21/2014PassTed DyeSheeting
Page 1 of 3
(Continued)
Permit Details Permit Number: 13-00435
860 Oak Hill Circle - SFR
860 Oak Hill Circle
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 07/15/2019 11:19 am
Permit
Inspection
Summary
Electrical Inspection Type
01/31/2014FailBret StoddardElectrical Rough-in
Need two small appliance circuits in kitchen, smoke alarms not linked together
throughout the house, nail plate needed for wire above switches in bathroom
upstairs, floor receptacle needed near stairway space, master bedroom needs
receptacle on short wall by closet, bath fans need NM-B connectors (2), conduit
needs installed for future circuits for basement, need access for Ufer in garage
for main electrical service, unfinished basement entirely, call for a re-inspect
when ready, inspected the electrical service on this inspection as well(Approved).
Inspector Comments:
02/05/2014PassBret StoddardCommercial Electrical Rough-in
Approved for cover-unfinished basement-need access for Ufer connection.
Conduit installed for basement wiring in front bedroom closet wall common with
garage.
Inspector Comments:
04/25/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
07/15/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Mechanical Inspection Type
01/28/2014FailDon AllenHVAC Rough-in
need to install exhaust fan in bathroomInspector Comments:
04/29/2014PassDon AllenHVAC Rough-in
04/29/2014PassDon AllenHVAC Final Inspection
all good for c/oInspector Comments:
Plumbing Inspection Type
12/18/2013FailDon AllenPlumbing Sewer
was never called in for inspection now coveredInspector Comments:
12/18/2013FailDon AllenPlumbing Water
was not called in for inspection all covered
no tracer line was installed
Inspector Comments:
12/24/2013PassDon AllenPlumbing Underground Inspection
good to cover the ground work inside the foundationInspector Comments:
01/28/2014PassDon AllenPlumbing Rough-in
good to cover th rough inInspector Comments:
04/29/2014PassDon AllenPlumbing Sewer
good to cover the sewerInspector Comments:
04/29/2014PassDon AllenPlumbing Water
good to cover the water line tracer was installedInspector Comments:
04/29/2014PassDon AllenPlumbing Final Inspection
all good for c/oInspector Comments: