Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00435 - 860 Oak Hill CirclePermit Inspection Summary Permit Status of (Open) as of Report Date: 07/15/2019 11:19 am Permit Details Permit Number: 13-00435 860 Oak Hill Circle - SFR 860 Oak Hill Circle Building - Single Family Residence Permit Issued Date: 12/03/2013 Permit Inspection Statistics 23Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 69.57% Permit Inspection History *Refer to Individual Inspection Report for more Details 12/13/2013PassTed DyeFooting Inspection 01/31/2014PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 07/21/2014PassTed DyeFoundation Inspection Building Inspection Type 01/15/2014FailQuinton OwensSheeting 1/3, QO: Seismic hold down in NW corner by Liv. rm window is not nailed to double stud. Finish nailing all holes in hold down straps. Some nailing missed (some missed/some spaced to far apart - staples should be 2" to 4"). 1/15: Not done yet Inspector Comments: 02/08/2014PassTed DyeInsulation Inspection Door off of kitchen dining needs insulation on left side near top.Inspector Comments: 02/10/2014PassTed DyeSheetrock/Drywall Inspection Tempered window required above tub. Finish attic access. Anchor bolts missing in basement bearing walls (6' oc max). Egress ladder in at least one window well. Grading to slope away from house. Inspector Comments: 04/25/2014FailQuinton OwensBuilding Final Back steps and landing approved only as temporary.Inspector Comments: 07/15/2014PassTed DyeBuilding Final 07/21/2014PassTed DyeSheeting Page 1 of 3 (Continued) Permit Details Permit Number: 13-00435 860 Oak Hill Circle - SFR 860 Oak Hill Circle Building - Single Family Residence Permit Status of (Open) as of Report Date: 07/15/2019 11:19 am Permit Inspection Summary Electrical Inspection Type 01/31/2014FailBret StoddardElectrical Rough-in Need two small appliance circuits in kitchen, smoke alarms not linked together throughout the house, nail plate needed for wire above switches in bathroom upstairs, floor receptacle needed near stairway space, master bedroom needs receptacle on short wall by closet, bath fans need NM-B connectors (2), conduit needs installed for future circuits for basement, need access for Ufer in garage for main electrical service, unfinished basement entirely, call for a re-inspect when ready, inspected the electrical service on this inspection as well(Approved). Inspector Comments: 02/05/2014PassBret StoddardCommercial Electrical Rough-in Approved for cover-unfinished basement-need access for Ufer connection. Conduit installed for basement wiring in front bedroom closet wall common with garage. Inspector Comments: 04/25/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 07/15/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 01/28/2014FailDon AllenHVAC Rough-in need to install exhaust fan in bathroomInspector Comments: 04/29/2014PassDon AllenHVAC Rough-in 04/29/2014PassDon AllenHVAC Final Inspection all good for c/oInspector Comments: Plumbing Inspection Type 12/18/2013FailDon AllenPlumbing Sewer was never called in for inspection now coveredInspector Comments: 12/18/2013FailDon AllenPlumbing Water was not called in for inspection all covered no tracer line was installed Inspector Comments: 12/24/2013PassDon AllenPlumbing Underground Inspection good to cover the ground work inside the foundationInspector Comments: 01/28/2014PassDon AllenPlumbing Rough-in good to cover th rough inInspector Comments: 04/29/2014PassDon AllenPlumbing Sewer good to cover the sewerInspector Comments: 04/29/2014PassDon AllenPlumbing Water good to cover the water line tracer was installedInspector Comments: 04/29/2014PassDon AllenPlumbing Final Inspection all good for c/oInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 13-00435 860 Oak Hill Circle - SFR 860 Oak Hill Circle Building - Single Family Residence Permit Status of (Open) as of Report Date: 07/15/2019 11:19 am Permit Inspection Summary Page 3 of 3