Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00445 - 1248 Franklin Drive - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 07/09/2019 10:18 am Permit Details Permit Number: 14-00445 1248 Franklin Drive - SFR 1248 Franklin Drive Building - Single Family Residence Permit Issued Date: 10/15/2014 Permit Inspection Statistics 26Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 73.08% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 10/17/2014PassTed DyeResidential Footing Inspection Footing layout only. Layout looks good. OK to dig. Check utility locations. Inspector Comments: 10/23/2014FailTed DyeResidential Footing Inspection 10/28/2014PassTed DyeFoundation Inspection 12/15/2014FailTed DyeSheeting Area's that missed being nailed are marked with green paint inside and out. One siesmic hold down had nails that missed the stud on one side.Also maked with green paint. These items can be re-inspected at the time of the framing inspection. Thank you Ted Inspector Comments: 01/13/2015FailTed DyeResidential Framing/Structure Inspection No inspection performed. Not ready for rough inspections, so not ready for framing either. Inspector Comments: 01/15/2015Pass Commercial Framing/Structure Inspection Stopped to inspect insulation at 8:30 but is was only half done. Insulator drove up just as i was ready to leave and said it would be ready about 11:30. Inspector Comments: 01/15/2015PassTed DyeResidential Insulation Inspection Garage and famity room windows are missing. Check those windows for insulation when installed. Inspector Comments: 01/20/2015FailTed DyeResidential Sheetrock/Drywall Inspection 03/10/2015PassTed DyeResidential Sheetrock/Drywall Inspection 05/04/2015PassTed DyeSidewalk Inspection 12" ganular baseInspector Comments: 05/15/2015FailTed DyeResidential Building Final trim out pull down stairs in garage. fire tape drywall next to pull down stairs. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 14-00445 1248 Franklin Drive - SFR 1248 Franklin Drive Building - Single Family Residence Permit Status of (Open) as of Report Date: 07/09/2019 10:18 am Permit Inspection Summary 05/20/2015FailTed DyeResidential Building Final trim out pull down stairs in garage. fire tape drywall next to pull down stairs Inspector Comments: 05/21/2015PassTed DyeResidential Building Final 06/01/2015PassTed DyeResidential Sheetrock/Drywall Inspection Electrical Inspection Type 01/13/2015PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 05/19/2015PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 01/06/2015FailDon AllenHVAC Rough-in need clearance around the water heater flue. Exhaust fans in the bathroom needs to be hooked up. Inspector Comments: 01/09/2015PassDon AllenHVAC Rough-in Good to cover the mechanical rough inInspector Comments: 05/21/2015PassDon AllenHVAC Final Inspection good for the c/oInspector Comments: Plumbing Inspection Type 11/06/2014PassDon AllenWater Meter Inspection Water meter looks goodInspector Comments: 11/06/2014PassDon AllenPlumbing Water Water looks goodInspector Comments: 11/06/2014PassDon AllenPlumbing Sewer 11/06/2014PassDon AllenPlumbing Underground Inspection plumbing under ground all good to coverInspector Comments: 12/12/2014PassDon AllenPlumbing Rough-in 01/09/2015PassDon AllenPlumbing Rough-in Good to cover the plumbing rough inInspector Comments: 05/21/2015PassDon AllenPlumbing Final Inspection good for the c/oInspector Comments: Page 2 of 2