LOAD SHORT FORM - 19-00407 - 813 S 2275 W - New SFR
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Load Short Form 5/30/18Date:Entire House Vince ByramBy: Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN; JANITROL; AMANA DISTI... Model GMSS960603BN Cond GSX130301B AHRI ref 7365096 Coil ARUF30B14A AHRI ref 5383471 Efficiency 96.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh27000 Heating output Btuh58000 Latent cooling Btuh0 Temperature rise °F70 Total cooling Btuh27000 Actual air flow cfm900 Actual air flow cfm900 Air flow factor cfm/Btuh0.030 Air flow factor cfm/Btuh0.076 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 374 3055 1700 93 130 Room2 81 543 93 16 7 Room3 189 2337 1031 71 79 Room4 231 2811 1277 85 97 Room5 64 965 101 29 8 Room6 147 2859 1072 87 82 Room7 173 3178 1107 96 84 Room9 33 1091 62 33 5 Room10 797 12802 5354 389 408 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W Entire House d 2090 29641 11797 900 900 Other equip loads 11987 973 Equip. @ 0.94 RSM 12004 Latent cooling 0 TOTALS 2090 41628 12004 900 900 2019-Jun-28 11:41:58 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Building Analysis 5/30/18Date:Entire House Vince ByramBy: Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilings Floors Infiltration Ventilation Humidification % of loadBtuhBtuh/ft²Component 27.1112634.9Walls 14.2591324.3Glazing 1.247911.4Doors 4.619241.5Ceilings 12.552194.14.1Floors 11.648441.9Infiltration 00Ducts 00Piping 16.16702Humidification 12.75284Ventilation0Adjustments 100.041628Total Cooling Walls Glazing Other Ceilings InfiltrationVentilation % of loadBtuhBtuh/ft²Component 8.510820.5Walls 71.2908937.4Glazing 0.91172.8Doors 8.310630.8Ceilings 000Floors 3.54460.2Infiltration 00Ducts 7.6973Ventilation 00Internal gains 00Blower 0Adjustments 100.012770Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 64 Btuh/ft²-°F Data entries checked. 2019-Jun-28 11:41:58 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Component Constructions 5/30/18Date:Entire House Vince ByramBy: Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 3000.4731274.9422.00.065633n 2400.4725034.9422.00.065507e 3000.4731274.9422.00.065633s 2410.4725064.9422.00.065507w 10820.47112634.9422.00.0652280all Partitions (none) Windows 61C: 61C; NFRC rated (SHGC=0.32); 6.67 ft head ht 0.320101e 347134.4245224.30 489934.4346124.300.320142w 837034.4591324.300.320243all Doors metal: Door, mtl pur core type 1172.7847911.410.50.15042e Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 10630.8419241.5250.00.0201266 Floors 22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet flr fnsh 00344427.010.00.355128 00177427.010.00.35566 00521927.010.00.355193all Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Project Summary 5/30/18Date:Entire House Vince ByramBy: Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75 Design TD °F76 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh29641 Structure Btuh11797 Ducts Btuh0 Ducts Btuh0Central vent (75 cfm)5284 Btuh Central vent (75 cfm)Btuh973 Outside air Outside airHumidificationBtuh6702Blower Btuh0 Piping Btuh0Equipment load Btuh41628 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh12004 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight0Fireplaces Structure Btuh-620 Ducts Btuh0Central vent (75 cfm)Btuh-1353 CoolingHeating Outside air20902090Area (ft²)Equipment latent load Btuh0 1880918809Volume (ft³)Air changes/hour 0.110.22 Equipment Total Load (Sen+Lat)Btuh12004 Equiv. AVF (cfm)3469 Req. total capacity at 1.00 SHR ton1.0 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMAN; JANITROL; AMANA DISTI... Model GMSS960603BN Cond GSX130301BAHRI ref 7365096 Coil ARUF30B14A AHRI ref 5383471Efficiency96.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh27000Heating output Btuh58000 Latent cooling Btuh0 Temperature rise °F70 Total cooling Btuh27000Actual air flow cfm900 Actual air flow cfm900 Air flow factor cfm/Btuh0.030 Air flow factor cfm/Btuh0.076Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2019-Jun-28 11:41:58 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:AED Assessment 5/30/18Date:Entire House Vince ByramBy: Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 40.2%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 719 Btuh (PFG - 1.3*AFG) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Right-J® W or ksheet 5/30/18Date:Entire House Vince ByramBy:Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1 Room name Entire House Room1 2 Exposed wall 285.0 ft 29.3 ft 3 Room height 9.0 dft 9.0 heat/coolft 4 Room dimensions ft374.4x1.0 5 Room area 2089.9 f t²374.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 633 633 3127 300 143 143 704 68 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 650 507 2503 240 0 0 0 0 .GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 101 0 2452 3471 0 0 0 0 .DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 42 42 479 117 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 633 633 3127 300 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 650 507 2506 241 122 93 460 44 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 142 0 3461 4899 28 0 689 975 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 1266 1266 1924 1063 374 374 569 315 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 830 128 3444 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 438 66 1774 0 63 5 134 0 6 c) AED excursion 719 252 Envelope loss/gain 24797 11351 2556 1654 12 a)Infiltration 4844 446 499 46 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)29641 11797 3055 1700 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 29641 11797 3055 1700 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 29641 11797 3055 1700 Air required (cfm)Air required (cfm)900 900 93 130 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Right-J® W or ksheet 5/30/18Date:Entire House Vince ByramBy:Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1 Room name Room2 Room3 2 Exposed wall 6.8 ft 27.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.8x6.8 ft11.8x16.0 5 Room area 80.9 f t²189.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 107 107 526 51 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 62 62 304 29 144 127 629 60 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 17 0 405 574 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 81 81 123 68 189 189 288 159 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 4 1 16 0 6 c) AED excursion -15 143 Envelope loss/gain 427 82 1864 987 12 a)Infiltration 116 11 473 44 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)543 93 2337 1031 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 543 93 2337 1031 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 543 93 2337 1031 Air required (cfm)Air required (cfm)16 7 71 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 3...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Right-J® W or ksheet 5/30/18Date:Entire House Vince ByramBy:Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1 Room name Room4 Room5 2 Exposed wall 30.5 ft 11.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft16.3x14.2 ft11.0x5.8 5 Room area 231.4 f t²64.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 99 99 489 47 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 128 99 490 47 0 0 0 0 .GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 28 0 689 975 0 0 0 0 .DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 147 147 726 70 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 231 231 352 194 64 64 98 54 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 10 1 36 0 42 7 192 0 6 c) AED excursion -57 -17 Envelope loss/gain 2293 1229 779 84 12 a)Infiltration 518 48 187 17 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2811 1277 965 101 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2811 1277 965 101 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2811 1277 965 101 Air required (cfm)Air required (cfm)85 97 29 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 4...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Right-J® W or ksheet 5/30/18Date:Entire House Vince ByramBy:Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1 Room name Room6 Room7 2 Exposed wall 24.3 ft 27.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.3x11.0 ft15.5x11.2 5 Room area 146.7 f t²173.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 120 120 593 57 20 20 96 9 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 99 74 366 35 101 76 373 36 .GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 25 0 608 861 25 0 608 861 .DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 128 128 630 60 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 147 147 223 123 173 173 263 145 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 147 24 657 0 173 27 741 0 6 c) AED excursion -42 -47 Envelope loss/gain 2446 1034 2711 1064 12 a)Infiltration 414 38 467 43 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2859 1072 3178 1107 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2859 1072 3178 1107 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2859 1072 3178 1107 Air required (cfm)Air required (cfm)87 82 96 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jun-28 11:41:58Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 5...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Right-J® W or ksheet 5/30/18Date:Entire House Vince ByramBy:Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1 Room name Room9 Room10 2 Exposed wall 12.3 ft 115.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.5x3.8 ft797.4x1.0 5 Room area 32.6 f t²797.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 252 252 1245 120 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 35 35 170 16 288 224 1104 106 .GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 23 0 547 775 .DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 42 42 479 117 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 77 77 378 36 176 176 867 83 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 323 225 1112 107 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 97 0 2366 3349 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 6 6 9 5 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 33 12 333 0 797 115 3112 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -10 512 Envelope loss/gain 881 43 10842 5173 12 a)Infiltration 210 19 1960 181 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1091 62 12802 5354 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1091 62 12802 5354 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1091 62 12802 5354 Air required (cfm)Air required (cfm)33 5 389 408 Job #: SF19B9 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing Heating and Electric 3939 E 240 N Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Vince@modernphe.com Scale: 1 : 63 Page 1 Right-Suite® Univ er s al 2018 18.0.19 RSU20477 2019-Jun-28 11:42:38 ...ightsoftware\SF19B9 ROCKFORD.rup N main Room9 Room10 82 cfm 344 cfm 82 cfm 33 cfm 82 cfm 82 cfm 82 cfm Job #: SF19B9 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing Heating and Electric 3939 E 240 N Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Vince@modernphe.com Scale: 1 : 63 Page 2 Right-S uite® Univ er s al 2018 18.0.19 RSU20477 2019-Jun-28 11:42:38 ...ightsoftware\SF19B9 ROCKFORD.rup N 2nd story Room1 Room2Room3 Room4 Room5 Room6 Room7 Room8 29 cfm 87 cfm 130 cfm 16 cfm79 cfm 97 cfm 29 cfm 96 cfm 218 cfm 183 cfm 176 cfm 12 x 8 14x3.25 6 " 12 x 8 2-14x3.25 6 " 6 " 6 "6 " 6 " 6 " 6 " 6 " 6 " 12 x 8 6 " 12 x 8 14x3.25 12 x 8 12 x 8 6 " 14x3.25 6 " 12 x 8 14x3.25 12 x 8 2019-Jun-28 11:41:59 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W SF19B9Job:Duct System Summary 5/30/18Date:Entire House Vince ByramBy: Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.306 / 0.394 in H2O in H2O0.306 / 0.394 Lowest friction rate in/100ft0.155in/100ft0.155 Actual air flow cfm900cfm900 Total effective length (TEL)ft452 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1130.035.5ShMt0x06.00.185130931700cRoom1 st1165.026.0ShMt0x06.00.16082781071cRoom10 st2140.031.8ShMt0x06.00.17882781071cRoom10-A st1A160.037.5ShMt0x06.00.15582781071cRoom10-B st2150.07.8ShMt0x06.00.19482781071cRoom10-C st1140.014.8ShMt0x06.00.19882781071cRoom10-D st1150.022.3ShMt0x06.00.178716543hRoom2 st2A160.030.5ShMt0x06.00.16179711031cRoom3 st2A150.016.3ShMt0x06.00.18497851277cRoom4 st1B170.018.5ShMt0x06.00.162829965hRoom5 st1A150.028.7ShMt0x06.00.17182872859hRoom6-A st1160.020.0ShMt0x06.00.17084963178hRoom7 st2130.014.3ShMt0x06.00.2125331091hRoom9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 555 556 0.155 834 10.1 12x8 ShtMetl st1A Peak AVF 194 171 0.155 291 6.8 12x8 ShtMetl st1 st2 Peak AVF 345 344 0.161 517 8.4 12x8 ShtMetl st2A Peak AVF 156 176 0.161 264 6.5 12x8 ShtMetl st2 st1B Peak AVF 29 8 0.162 44 3.3 12x8 ShtMetl st1A 2019-Jun-28 11:41:59 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...am\Documents\wrightsoftware\SF19B9 ROCKFORD.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb3 0x 1560 176 90.2 0.437 557 5.3 3.25x14 10x9 SJSp rt1 rb5 0x 3440 331 190.0 0.207 544 8.0 2-3.25x14 2-10x18 SJSp rt1 rb1 0x 1870 218 148.7 0.265 691 6.4 3.25x14 10x9 SJSp rt2 rb2 0x 1830 166 234.8 0.168 580 6.6 3.25x14 10x9 SJSp rt2 rb4 0x 290 8 254.2 0.155 93 3.4 3.25x14 10x9 SJSp rt2A Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 500 508 0.207 761 9.2 12x8 ShtMetl rt2 Peak AVF 400 392 0.155 599 8.9 12x8 ShtMetl rt2A Peak AVF 29 8 0.155 44 3.4 12x8 ShtMetl rt2