HomeMy WebLinkAboutM4 HVAC DETAILS.pdfSHEET NUMBER RE V I S I O N S : DA T E : JO B N O : DR A W N : CH E C K E D : AC G # : 06 / 2 0 / 1 9 21 7 5 AA , K K , S O AR , C F 19 2 0 1 9 1 14 8 1 7 W e s t 9 5 t h S t r e e t L e n e x a , K a n s a s 6 6 2 1 5 P 9 1 3 3 2 2 5 1 5 0 F 9 1 3 3 2 2 5 1 5 5 ww w . A c e r t u s G r o u p . c o m FRANCHISEE 7300 W. 129TH STREET OVERLAND PARK, KANSAS 66213 PHONE: (913) 327-5555 FAX: (913) 327-5850 16 3 W M A I N S T . S U I T E T B D RE X B U R G , I D A H O PI Z Z A H U T # 2 1 7 5 06/20/19 H. V . A . C . D E T A I L S M4 C OF PANEL POINT BOTTOM CHORD OF ROOF JOIST ROD HANGER JOIST WEB MEMBER C OF PANEL POINT STEEL PLATE WASHER GRINNELL FIG. 60. OR EQUAL BOTTOM CHORD OF ROOF JOIST ROD HANGER L L EXTEND ANGLE BETWEEN JOISTS, 6' MAX. 1/4 L 5 X 3 X 3/8 1/4 1/4 1/4 1/4 ASTM 325, TYPE 3 NUT & WASHER SIZE AS PER LOADING C3 X 4.1 L 5 X 3 X 3/8 ASTM 325, TYPE 3 NUT & WASHER SIZE AS PER LOADING C3 X 4.1 3 1/4" MAX. 3 1/4" MAX. 18"18" LOCK TYPE WASHER 1" MIN. 1" MIN. JOIST WEB MEMBER 3-1/4" MAX. WELD ROD HANGER JOIST WEB MEMBER 3-1/4" MAX. C OF PANEL POINT ROD HANGER L 1/4 L 2-1/2 x 1-1/2 x 5/16 C OF PANEL POINT L IMPORTANT NOTE: NO EXCEPTIONS! BOTH ENDS OF C3 & BOTH JOIST ANGLES BOTTOM CHORD OF ROOF JOIST BOTH ENDS OF C3 & BOTH JOIST ANGLES ROD HANGER SUPPORT STRUCTURAL STEEL MEMBERROD HANGER SIZED AS NOTED: AS RECOMMENDED BY MANUF. OF EQUIP. SUPPORTED: AS REQ'D. BY WEIGHT OF ITEM TO BE SUPPORTED BOTTOM CHORD OF ROOF JOIST ASTM 325, TYPE 3 NUT & WASHER ASTM 325, TYPE NUT & WASHER, TOP & BOTTOM OF ANGLE STEEL PLATE WASHER GRINNELL FIG. 60. OR EQUAL EXTEND ANGLE BETWEEN JOISTS, 6' MAX. BOTTOM CHORD OF ROOF JOIST NOTES SCHEMATIC ROD HANGER ATTACHMENT EQUIPMENT SUPPORT FROM BAR JOIST*N.T.S.1N.T.S.2N.T.S.3 N.T.S.7 N.T.S.6 N.T.S.5 N.T.S.9N.T.S.10N.T.S.12 N.T.S.8 N.T.S.13N.T.S.16NOT USED NOT USED NOT USED NOT USED HOOD EXHAUST DUCT SYSTEM DETAIL ALL SUPPORTS &/OR BRACING OF EQUIPMENT, CEILING GRID, LIGHT FIXTURES, & ANY OTHER INSTALLED DEVICES SHALL BE COMPLIANT WITH LOCAL SEISMIC ZONE REQUIREMENTS. N.T.S.4 *LOADS MORE THAN 200 POUNDS BUT LESS THAN 400 POUNDS EQUIPMENT SUPPORT FROM BAR JOIST* *LOADS LESS THAN 200 POUNDS HOOD NOTES (2) UL LISTED GLOBE LIGHTS PAN RACK RETENTION CLIP AIR FLOW REQUIREMENTS 1. CAPTIVE AIRE IS NOT LIABLE FOR IMPROPER FUNCTION OF THE SYSTEM CAUSED BY CHANGES IN THE SYSTEM STATIC PRESSURE OR OVER ALL AIR FLOW VOLUME FROM THE ORIGINAL SPECIFIED DESIGN POINTS. EXHAUST DUCT AIR FLOW VELOCITY MUST BE BETWEEN 1500 AND 2200 FPM WITH WELDED DUCT. 2. EXHAUST AIR FLOW MUST BE BALANCED WITH OTHER EXHAUST & MAKE-UP AIR SYSTEMS AND THE STORE HVAC SYSTEMS UPON INSTALLATION. TEST & BALANCE IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR. FAN OPERATING SPEED, BELTS AND PULLEYS SHOULD BE RECHECKED AFTER 60 DAYS TO ENSURE PROPER PERFORMANCE. STATIC PRESSURE VALUES ARE GIVEN FOR THE HOOD ONLY AND DO NOT INCLUDE DUCTWORK AND ROOFTOP FANS. 3. AIR FLOWS ARE NOTED IN MECHANICAL SCHEDULE. 4. CAPTIVE AIRE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS TO MEET CODE OR JOB REQUIREMENTS. FIRE EXTINGUISHING SYSTEM 1. FACTORY INSTALLED FIRE EXTINGUISHING SYSTEM PIPING SUPPLIED AND INSTALLED IN ACCORDANCE WITH NFPA 96 BY FIRE SUPPRESSION INSTALLER. 2. CAUTION: FIRE EXTINGUISHING SYSTEM INSTALLED ON SITE MUST BE DONE IN ACCORDANCE WITH AVTEC TO INSURE THAT PIPE DOES NOT INTERFERE WITH HOOD PERFORMANCE. IMPROPER INSTALLATION MAY VOID UL LISTING. WIRING NOTES. 1. FAN CONTROLS (E.G. ON/OFF SWITCH), THERMAL OVERLOAD PROTECTION AND WIRING FOR FAN TO BE FURNISHED BY OTHERS. 2. ANSUL, FAN AND FRYER INTERLOCK SHALL BE WIRED BY OTHERS ACCORDING TO SCHEMATIC FURNISHED WITH ARCHITECTURAL DRAWINGS. CONSTRUCTION 1. HOOD SHALL BE FABRICATED IN ACCORDANCE WITH NFPA BULLETIN #96 AND SHALL BEAR THE NSF SEAL OF APPROVAL. HOODS SHALL BE LISTED UNDER UL 710 EXHAUST HOODS FOR COMMERCIAL COOKING EQUIPMENT UL FILE # MH18450. GENERAL INSTALLATION GUIDELINES: 1. MEASURE AND MARK THE DESIRED HEIGHT AND CENTERLINE OF THE HOOD ON THE WALL. (REFER. TO THE ARCHITECT'S PLAN FOR THE DIMENSION) THE HEIGHT OF THE PLATE SHELF ABOVETHE FIXED FLOOR IS A CRITICAL DIMENSION. 2. SECURE THE WALL MOUNTING FLANGES AT TOP AND BOTTOM OF HOOD TO A MINIMUM OF TWO (2) OR MORE WALL STUDS. 3. ALL MOUNTING AND/OR BRACING SHALL COMPLY WITH SEISMIC ZONE 3 REQUIREMENTS. 10-1/2" 10-1/2" 1-1/2" 1-1/2" 21"TYP FIELD DRILL FOR MOUNTING TO STRUCTURE FACTORY SUPPLIED SHROUD SHIPPED LOOSE; ATTACHED BY CONTRACTOR FIELD DRILL FOR MOUNTING TO STRUCTURE REMOVABLE BOTTOM SIDE SKIRTS SKINNED ENDS WITH FINISH ON BOTH OUTER AND INNER EXHAUST FAN NOTE: 1.WRAP GREASE DUCT CONTINUOUS AS SHOWN BELOW FOR ENTIRE LENGTH FROM KITCHEN HOOD CONNECTION TO EXHAUST FAN ON ROOF. 2.BANDING REQUIREMENTS: USE 304 STAINLESS STEEL FOR MIN. ONE HOUR RATING 3.WRAP SUPPORT HANGER SYSTEM INDEPENDENTLY WITH SAME THICKNESS FOR EXTERNAL FIRE THREAT CONDITIONS. 3"MIN LONGITUDINAL OVERLAP AT BLANKET JOINT 3"MIN PERIMETER OVERLAP AT BLANKET JOINT BANDING - 304 SS 3/4"W X .015"THK MIN HOOD EXHAUST DUCT TWO LAYERS 1-1/2" THICK FIREMASTER BLANKET FOR MIN. ONE HOUR FIRE RATING (STAGGER JOINTS 12"BETWEEN JOINTS) HOOD INSTALLATION: 1. INSTALLATION OF VENTILATION SYSTEM WILL BE BY CONTRACTOR. EXHAUST COLLARS WILL BE PROVIDED BY CONTRACTOR. HOODS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA AND ALL OTHER APPLICABLE LOCAL, STATE AND NATIONAL CODES. SPECIAL ATTENTION MUST BE GIVEN TO CODES REGARDING CLEARANCE TO SURROUNDING COMBUSTIBLE AND LIMITED COMBUSTIBLE (NFPA96) CONSTRUCTION (WALLS, CEILINGS, ETC.). 2. CONTRACTOR IS RESPONSIBLE FOR DRILLING RETAINING BOLT HOLES INTO WALL MOUNTING FLANGES AT TOP AND BOTTOM OF HOOD AND PROVIDING THE HARDWARE. 3. CEILING ENCLOSURE FURNISHED BY HOOD MANUFACTURER WILL BE ATTACHED IN THE FIELD BY CONTRACTOR. 4. DUCTWORK BETWEEN HOOD AND ROOF TOP CURB TRANSITION WILL BE PROVIDED BY CONTRACTOR. GENERAL INSTALLATION GUIDELINES: CONTINUED 3. FIELD MEASURE AND LAYOUT DUCTWORK AS CLOSE AS POSSIBLE TO THE ARCHITECTURAL DRAWING. DUCTWORK SHOULD NOT EXCEED TWO (2) RADIUS-90 DEGREE TURNS AND TEN (10) FEET IN LENGTH. CONSULT FACTORY 800/621-8560 X 4129 FOR DUCTWORK THAT EXCEEDS DESIGN LIMITS--FAN PACKAGE MUST BE MODIFIED FOR SITE ADAPTATION. 4. POSITION THE FABRICATED DUCTWORK TO MATCH THE OULET LOCATION ABOVE THE HOOD. THE DUCT MUST BE SIZED AT 7" X 7". 5. A CONTINUOUS LIQUID TIGHT WELD TO THE COLLAR TRANSITION AND DUCTWORK WILL MEET ANY AND ALL CODE REQUIREMENTS. 6. CONNECT THE DUCTWORK TO THE CURB TRANSITION TERMINATING AT THE TOP OF THE VENTED CURB EXTENSION BELOW THE FAN BASE. DO NOT TERMINATE THE DUCTWORK AT THE ROOF-LINE. DUCTWORK MUST BE WELDED WITH A CONTINUOUS LIQUID TIGHT WELD AT EXHAUST FAN CURB TRANSITION. 7. ATTACH FACTORY SUPPLIED HINGE KIT AND GREASE TROUGH TO FAN CURB PER NFPA96-2004. 8. ENCLOSE DUCT AS REQUIRED BY LOCAL, STATE AND NATIONAL FIRE PROTECTION AND MECHANICAL CODES OBSERVING IN PARTICULAR THE CLEARANCE TO COMBUSTIBLE PROVISIONS. 9. CONNECT AND TEST THE HOODS FIRE SUPPRESSION SYSTEM. ONLY PROFESSIONALLY QUALIFIED PERSONS SHOULD PERFORM THESE FUNCTIONS. 10. CHECK TO ENSURE PROPER PLACEMENT OF THE GREASE FILTERS AND GREASE CUP. 11. REMOVE THE PROTECTIVE PVC COATING FROM ALL OF THE METAL SURFACES PRIOR TO USE OF THE APPLIANCES. 12. RUN CHECK THE EXHAUST FAN AND FRYER INTERLOCK. 13. CERTIFIED TEST & BALANCE CONTRACTOR MUST TAKE FPM READINGS ACROSS THE FILTER BANK AND CONFIRM THAT EXHAUST FAN IS OPERATING AT OR ABOVE THE EXHAUST CFM DESIGN POINT. ANY AIR FLOW LEVEL BELOW DESIGN POINT IS NOT ACCEPTABLE. DO NOT ACCEPT MOTOR RPM READINGS AS A SUBSTITUTE FOR FILTER AIRFLOW LEVELS. 14. CALL FOR FUNCTIONAL INSPECTIONS AS REQUIRED. 15. APPLY FABRICATED TRIM (CONTRACTOR SUPPLIED) TO THE CEILING AND WALL AS REQUIRED. FACTORY SUPPLIED SHROUD (ENCLOSURE PANELS) FROM TOP OF HOOD TO CEILING SHOULD BE SCREWED TO ANGLE AT TOP EDGE OF HOOD WITH SELF-TAPPING SS SCREWS. 16. CLEAN THE SURFACES OF THE HOOD WITH A MILD DETERGENT USING CARE NOT TO SCRATCH OR DENT THE SURFACE. 17. CONTRACTOR RESPONSIBLE FOR REDIRECTING AIRFLOW FROM HVAC DIFFUSERS WITHIN 6-FEET OF FRYER HOOD AWAY FROM HOOD AND COVER DISCHARGE WITH PERFORATED PANEL. 18. CONTRACTOR RESPONSIBLE FOR REDIRECTING HVAC RETURNS WITHIN 10-FEET OF FRYER HOOD AWAY FROM HOOD. 19. CONTRACTOR RESPONSIBLE FOR STORE TEST & BALANCE OF HVAC AND ALL KITCHEN EXHAUST AND SUPPLY FANS ACCORDING TO THE MECHANICAL AIR FLOW BALANCE SCHEDULE. VENTED CURB EXTENSION LIQUID TIGHT FLEXIBLE CONDUIT FIRE-PROOF INSULATION FRYER HOOD EXHAUST FAN GREASE TRAP ROOF DECK 8" M I N . MIN. 16 GA. WELDED EXHAUST DUCT - EXTEND MIN. OF 18" ABOVE ROOF DECK PER NFPA NEMA 3R DISCONNECT FACTORY WIRED FROM MOTOR TO DISCONNECT THROUGH THE BREATHER TUBE DISCHARGE HEIGHT 40" MINIMUM ROOF SURFACE ROOFTOP UNIT SUPPLY AIR DUCT (REFER TO FLOOR PLAN FOR EXACT SIZE) FLUE HOOD SDD SDD ROOF TOP UNIT SMOKE DETECTOR IN R/A AND S/A DUCTS OUTSIDE AIR INTAKE HOOD MANUFACTURER'S ROOF CURB FLASHING & COUNTER FLASHING ALL AROUND EXISTING ROOF CONDENSATE DRAIN FLEXIBLE CONNECTION (TYP) RETURN AIR DUCT NOT USED