Loading...
HomeMy WebLinkAboutM3 HVAC DETAILS.pdfSHEET NUMBER RE V I S I O N S : DA T E : JO B N O : DR A W N : CH E C K E D : AC G # : 06 / 2 0 / 1 9 21 7 5 AA , K K , S O AR , C F 19 2 0 1 9 1 14 8 1 7 W e s t 9 5 t h S t r e e t L e n e x a , K a n s a s 6 6 2 1 5 P 9 1 3 3 2 2 5 1 5 0 F 9 1 3 3 2 2 5 1 5 5 ww w . A c e r t u s G r o u p . c o m FRANCHISEE 7300 W. 129TH STREET OVERLAND PARK, KANSAS 66213 PHONE: (913) 327-5555 FAX: (913) 327-5850 16 3 W M A I N S T . S U I T E T B D RE X B U R G , I D A H O PI Z Z A H U T # 2 1 7 5 06/20/19 M3 H. V . A . C . D E T A I L S CONICAL TEE MASTIC TO DUCT WITH SEAL INSULATION DUCT SPINNING TEE ONTO TO TEE BEFORE DUCT SEALER CAULK APPLY A BEAD OF INSULATION FLEX. DUCT DUCT FLEX. CLAMP BAND SEALER TAPE INSULATION INSULATION DUCT WRAP DIFFUSER CEILING FLEX DUCT MAX. 5' LENGTH OF BAND CLAMP INSULATION EXTERNAL GUARD INSULATION DAMPER TEE CONNECTOR CONICAL SPIN-IN FLOW AIR SUPPLY AIR DUCT RECTANGULAR INSULATION INTERNAL TYPICAL ROUND BRANCH DUCT TAKE-OFF 5' - 0 " M A X . ON THESE DRAWINGS TYPICAL DUCT BRANCH 6" RETURN AIR DEVICE SUPPLY AND/OR FINISHED AREAS CEILING IN HANGER STRAP DETAIL SCREWS AS PER TERMINATIONS ENDS OF ALL DUCT OR RODS WITHIN 6" OF PROVIDE HANGER STRAPS TYPICAL DUCT RUN TERMINATION SCHEMATIC FLANGED DUCT CONNECTION DRIVE CLIP BOLTS AT EACH CORNER SHEET METAL DUCTGASKET DUCT CONNECTION FLANGE MOP ENDS OF INSULATION W/ MASTIC BEFORE BUTTING SECTIONS TOGETHER. SEE SPECS. INSULATION SHALL EXTEND PAST THE END OF SHEET METAL DUCT THE FULL THICKNESS OF THE DUCT FLANGE IN ORDER FOR INSULATION SECTIONS TO BUTT TOGETHER INSULATION METAL NOSING AT INTERNALLY LINED DUCT ATTACH METAL HOSING TO DUCT W/ SCREWS, RIVETS, WELDS METAL NOSING AT ALL INSULATION BEGINNING POINTS, REGARDLESS OF VELOCITY, SUCH AS FAN DISCHARGE, DOWNSTREAM AIR FLOW NOSING REQ'D. ALL SIDES OF DUCT. NOSING INSULATION-SEE SPECS. FOR THICKNESS OF DAMPERS, COILS, ETC. TO BE SAME GAUGE AS DUCT FLEXIBLE DUCT LINER INSTALLATION SCHEMATIC LAPPED AND COMPRESSED FASTENERS UPSTREAM TRANVERSE EDGES TO BE COATED WITH ADHESIVE, ALL SIDES LONGITUDINAL JOINT NOTES: 1. SEE "SMACNA" DUCT CONSTRUCTION STANDARDS MANUAL 1st ED. 1985, PAGE-2-28 FIG.-2- 22 FOR FASTENER SPACING DIMINSIONS. SEE PAGE 2-29 OF THIS STANDARD FOR FASTENER TYPE. CORNER BREAK AI R F L O W 2. INTERNAL INSULATION SHALL EXTEND OUTWARD FROM DUCT APPROXIMATELY 1/16" TO INSURE THAT INSULATION EDGES WILL BUTT WHEN DUCT SECTIONS ARE JOINED. INTERNAL INSULATION SEE SPECIFICATIONS E E A B B C B C C DUCT LINER MATERIAL SHEET METAL DUCT EXTERIOR TOP SECTION OF DUCT LINER TO BE SUPPORTED BY LINER ON SIDE OF DUCT. ADHERE LINER TO DUCT WITH ADHESIVE AND PINS. SEE SPECS. BUTT ALL JOINTS TIGHT AND SUPPLY 100% COVERAGE OF ADHESIVE SEE SPECS. TYPICAL SECTION THRU INTERNALLY LINED DUCT TYPICAL DUCT TRANSITION AND OFFSET AIR FLOW 30° MAX. ON CONTRACTING FLOW(7" IN 12") NOTE: SEE FIG. 2-9, PG. 2-10, SMACNA 1st ED., 1985 FULL RADIUS (R=W) R. TRANSITION OFFSET R. W DUCT PENETRATION THRU NON-FIRE RATED WALL NON-FIRE RATED WALL SHEET METAL SCREWS DUCTWORK1-1/2" X 1-1/2" X 18 GA. BENT PLATE WALL COLLAR. MITER CORNERS TYPICAL RADIUS ELBOW W R=W NOTE: SEE "SMACNA" DUCT MANUAL, 1st ED., 1985, FIG. 2-2 PAGE 2-2 LINER ADHERED TO THE DUCT WITH 100% COVERAGE OF ADHESIVE N.T.S.1N.T.S.2N.T.S.3 N.T.S.7 N.T.S.6 N.T.S.5 N.T.S.9N.T.S.10N.T.S.11N.T.S.12 N.T.S.8 N.T.S.4 N.T.S.15 N.T.S.14 N.T.S.13N.T.S.16NOT USED NOT USED NOT USED NOT USED LAY-IN CEILING DIFFUSER BAND CLAMP CEILING SUPPLY DIFFUSER WITH ROUND NECK INSULATION SUPPLY AIR DIFFUSER TYPE C.D. SEE SPECS. SEAL WITH MASTIC OR TAPE INTERNAL DUCT INSULATION SEE SPECS. EXTERNAL DUCT INSULATION LOCKING TYPE STRAP FLEXIBLE DUCTWORK SUPPORT NYLON BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED WITH VOLUME DAMPER AND DAMPER LOCK WITH EXTENSION PRE-INSULATED FLEXIBLE DUCT AS REQUIRED, INSTALL FULLY STRETCHED, PERMANENTLY SEALED AND SUPPORTED TO PREVENT KINKING AND SHARP TURNS WORM GEAR DRAWBAND (TYPICAL) CEILING DIFFUSER AS SCHEDULED CEILING INSULATED DUCT PROVIDE FULL SIZE HARD ELBOW FOR TRANSITION TO VERTICAL ·DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. ·5' LENGTH OF FLEX DUCT MAXIMUM PER BRANCH DUCT TAKEOFF. MAX. SAG 1/2" PER FOOT OF SUPPORT SPACING 5'- 0 " M A X I M U M 1" MINIMUM METAL BAND 1" MINIMUM METAL BAND METAL WIRE