HomeMy WebLinkAboutE3 ELECTRICAL LIGHTING PLAN.pdf4
B-11
EM3
6
B-3
A
NL
B-3
A
g
B-3
PANELBOARD 'A'
PANELBOARD 'B'
OSf
7
3
S
S
S
A
B-2
f
C
B-2
NL
K1
B-2
EM2
B-2
SWITCH
BANK
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
C
B-2
a
D
D
D
J
J
J
J
JB4
B-2
a
JB4
B-2
a
JB2
B-2
a
JB2
B-2
a
EM1
B-2
EM1
B-2
EM1
B-2
1
E
B-1
d
E
B-1
d
E
B-1
e
S
e
S d
5
5
A-9
A-9
A
b
B-3
A
b
B-3
A
b
B-3
A
b
B-3
A
b
B-3
A
b
B-3
A
b
B-3
A
c
B-3
A
c
B-3
A
c
B-3
A
c
B-3
A
c
B-3
A
c
B-3
A
c
B-3
A
c
B-3
EM2
B-3
EM2
B-3
EM2
B-3
EM2
B-3
EM2
B-3
EM2
B-3
EM2
B-3
A
g
B-3
A
g
B-3
A
g
B-3
K2
B-3
K2
B-3
K2
B-3
S 3,g
A
b
B-3
S
3,g
S
3,c
2
SHEET NUMBER
RE
V
I
S
I
O
N
S
:
DA
T
E
:
JO
B
N
O
:
DR
A
W
N
:
CH
E
C
K
E
D
:
AC
G
#
:
06
/
2
0
/
1
9
21
7
5
AA
,
K
K
,
S
O
AR
,
C
F
19
2
0
1
9
1
14
8
1
7
W
e
s
t
9
5
t
h
S
t
r
e
e
t
L
e
n
e
x
a
,
K
a
n
s
a
s
6
6
2
1
5
P
9
1
3
3
2
2
5
1
5
0
F
9
1
3
3
2
2
5
1
5
5
ww
w
.
A
c
e
r
t
u
s
G
r
o
u
p
.
c
o
m
FRANCHISEE
7300 W. 129TH STREET
OVERLAND PARK, KANSAS
66213
PHONE: (913) 327-5555
FAX: (913) 327-5850
16
3
W
M
A
I
N
S
T
.
S
U
I
T
E
T
B
D
RE
X
B
U
R
G
,
I
D
A
H
O
PI
Z
Z
A
H
U
T
#
2
1
7
5
06/20/19
E3
NOTE:
5 LIGHT FIXTURE SCHEDULE NOTES
LIGHTING FIXTURE CONTACTS:
ACCUSERV EQUIPMENT & SUPPLY
3865 PRODUCE RD., SUITE #208, LOUISVILLE, KY 40218,
PHONE: 877-707-7378, FAX: 502-961-0357.
LIGHTING FIXTURE SCHEDULE 4
1SWITCH BANKELECTRICAL LIGHTING PLAN 1/4" = 1'-0"2
3
ALL CEILING FIXTURES AND
PENETRATIONS TO CONFORM TO
ANSI/UL 263 STANDARDS.
ALL LIGHT FIXTURES ON LIGHT FIXTURE SCHEDULE FURNISHED BY OWNER AND INSTALLED
BY ELECTRICAL CONTRACTOR.
1.OWNER WILL PROVIDE LIGHT FIXTURES WITH ELECTRONIC BALLASTS. COMPACT
FLUORESCENT ELECTRONIC BALLASTS SHALL HAVE END-OF-LIFE PROTECTION CIRCUIT TO
PREVENT WELDING OF LAMPS IN SOCKETS OR LAMP BREAKAGE. SEE SPECIFICATIONS.
2.OWNER WILL PROVIDE ARROWS AND FACES AS INDICATED ON THE DRAWINGS. FIXTURES ARE
PROVIDED WITH REMOVABLE CHEVRONS FOR DIRECTIONS INDICATED ON PLAN.
3.OWNER WILL PROVIDE TRACK, END FEEDS, AND COUPLING DEVICES IN QUANTITIES AS
REQUIRED TO FORM THE TRACK LENGTHS SHOWN. REFER TO THE PLANS FOR TRACK
LOCATION. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ELEVATIONS FOR
EXACT LOCATIONS OF LIGHTING FIXTURES.
4.ELECTRICAL CONTRACTOR SHALL VERIFY ALL FIXTURE LOCATIONS WITH ARCHITECTURAL
PLANS.
5.ELECTRICAL CONTRACTOR SHALL INSTALL ALL CEILING MOUNTED LIGHTING FIXTURES IN
LOCATIONS AS INDICATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN.
6.CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER.
7.CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING HARDWARE.
8.SPEAKERS INSTALLED BY OTHERS.
9.VERIFY LOCATION OF NEW SWITCH BANK WITH NPC FACILITES/PROJECT MANAGER.
B-2
a b
B-3
NOTE: PROVIDE PILOT LIGHTS FOR SWITCHES NOTED
WITH A "PL" NEXT TO IT. PILOT LIGHTS ARE REQUIRED
FOR ALL SWITCHES CONTROLLING LIGHTS FIXTURES
THAT ARE NOT VISIBLE FROM SWITCH LOCATION.
PL
NOTE: VERIFY LOCATION OF NEW SWITCH BANK W/ NPC
FACILITIES/PROJECT MANAGER.
KEY NOTES
c
B-3
PL
3-WAY
COOLER/FREEZER LIGHTS FURNISHED BY MANUFACTURER. CIRCUIT AS SHOWN. NO
AUTOMATIC CONTROLS FOR THIS SPACE ARE REQUIRED SINCE THE LIGHTS HAVE AN
EFFICACY OF MORE THAT 40 LM/W.
PROVIDE TIME CLOCK, EXTERIOR PHOTOCELL SENSOR AND LIGHTING CONTACTOR AS
SHOWN IN DETAIL 6 ON THIS SHEET. MOUNT TIME CLOCK AND LIGHTING CONTACTOR
ADJACENT TO PANELBOARD 'B' AND MOUNT EXTERIOR PHOTOCELL SENSOR ON ROOF PER
MANUFACTURER LITERATURE.
VERIFY EXACT LOCATION OF SWITCH BANK WITH NPC FACILITIES/PROJECT MANAGER.
SIGNAGE DISCONNECT SWITCH; NEMA 3R, LOCKABLE. EXACT LOCATION TO BE DETERMINED
IN FIELD.
CONNECT HOOD LIGHTING WITHIN OVEN AND FRYER HOODS TO HOOD CONTROL PANEL
CONTROL CIRCUIT. COORDINATE ALL WIRING AND REQUIRED CONNECTION WITH HOOD
MANUFACTURER.
MOUNT EXTERIOR EMERGENCY EXIT LIGHTING FIXTURE @ 96" A.F.F. ON FACE OF EXTERIOR
WALL. CIRCUIT AS INDICATED. COORDINATE EXACT LOCATION WITH BUILDING OWNER AND
TENANT.
PROVIDE WALL MOUNTED OCCUPANCY SENSOR AS SHOWN ON PLANS FOR CONTROL OF
RESTROOM LIGHT AND EXHAUST FAN. WATTSTOPPER MODEL# PW-301.
1
2
3
4
5
6
EL
E
C
T
R
I
C
A
L
LI
G
H
T
I
N
G
P
L
A
N
NO.
QUANTITY
LOCATION MANUFACTURER / CATALOG NUMBER DESCRIPTION
LAMP
VOLT WATT REMARKSMOUNTING
#TYPENEWEXISTING
A
A5
14 ENTRY ACCUSERV / 00395-016 / CT6FB / RC6-12W DOWNLIGHT -LED CEILING 120 12 TRIM: BLACKC
3 ENTRY ACCUSERV / ITEM: BES00298-105 CORD HUNG PENDANT
WITH 18W GU24 BASE
1 9.5W A19 LED
2,700K
CEILING 120 9.5 FINISH: CORD HUNG PENDANT WITH
RED SAND GLASS SHADE
D
1 ENTRY BEST LIGHTING PRODUCTS
EZXTEU-2-R-B-EM
LED EXIT SIGN -LED CEILING 120 3 BLACK EXIT FIXTURE WITH EMERGENCY BATTERY.
SEE LIGHTS FIXTURE SCHEDULE NOTE #2.
K1
3 KITCHEN BEST LIGHTING PRODUCTS
EZXTEU-2-R-W-EM
LED EXIT SIGN -LED CEILING 120 3 WHITE EXIT FIXTURE WITH EMERGENCY BATTERY.
SEE LIGHTS FIXTURE SCHEDULE NOTE #2.
K2
3 ENTRY EXITRONIX / NFT-B-G2 EMERGENCY LIGHT -INCLUDED WALL 120 -EMERGENCY FIXTURE WITH 90 MINUTE
EMERGENCY BATTERY BACKUP. FINISH: BLACK
EM1
8 KITCHEN EXITRONIX / NFT-W-G2 EMERGENCY LIGHT -INCLUDED WALL 120 -EMERGENCY FIXTURE WITH 90 MINUTE
EMERGENCY BATTERY BACKUP. FINISH: WHITE
EM2
1 EXTERIOR ACCUSERV / ITEM: CAMN/LX6-DB EXTERIOR
EMERGENCY LIGHT
-6W XENON WALL 120 -EMERGENCY FIXTURE
WET LOCATION RATED
EM3
4 ENTRY ACCUSERV / ITEM: 2001-002 TRACK LIGHT HEADS 1 PAR20 LED TRACK 120 8 FINISH: BLACK
2 ENTRY ACCUSERV / ITEM:6048BK 2' TRACK --CEILING --FINISH: BLACK
REFER TO LIGHT FIXTURE SCHEDULE NOTE #3
J
JB2
3 WALK-IN SUPPLIED BY WALK-IN COOLER/FREEZER ---SURFACE --E
6 INTERIOR LIGHTING & EXTERIOR SIGNAGE CONTROL DIAGRAM
21 KITCHEN/
RESTROOM
PHILIPS / DAY-BRITE
#2TG48L835-4-FS-02F-UNV
2' x 4' LED TROFFER -INCLUDED LAY-IN GRID UNV 45 2X4 LED TROFFER WITH 3500K COLOR
TEMPERATURE
1 KITCHEN PHILIPS / DAY-BRITE
#2TG38L835-2-FS-02F-UNV
2' x 2' LED TROFFER -INCLUDED LAY-IN GRID UNV 43.5 2X2 LED TROFFER WITH 3500K COLOR
TEMPERATURE
0 EXTERIOR RAB / ITEM: WP2H150QT/PC WALL PACK -
BRONZE FINISH
-ED17
150W
WALL 120 185 SUFFACE MOUNT FIXTURE
AT 8'-0" AFF TO CENTER
W1
2 ENTRY ACCUSERV / ITEM:6048BK 4' TRACK --CEILING --FINISH: BLACK
REFER TO LIGHT FIXTURE SCHEDULE NOTE #3
JB4
TC
N
TIME SWITCH: TORK MODEL #DLC400BP
B-3
LOBBY AREA
KITCHEN AREA
H B-19
B-2
EXIT SIGN/EMERGENCY LIGHTING
EXIT SIGN/EMERGENCY LIGHTING
B-11 SIGNAGE
SPARE
a
b
c KITCHEN AREA
LIGHTING CONTROLS SYSTEM TESTING
REQUIREMENTS
PROVIDE EVIDENCE THAT THE LIGHTING CONTROL SYSTEMS HAVE
BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND
SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN
PROPER WORKING CONDITION IN ACCORDANCE WITH THE
CONSTRUCTION DOCUMENTS AND MANUFACTURER'S
INSTRUCTIONS.
OCCUPANT SENSOR CONTROLS:
THE FOLLOWING PROCEDURES SHALL BE PERFORMED:
1.CERTIFY THAT THE OCCUPANT SENSOR HAS BEEN LOCATED
AND AIMED IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS.
2.EACH SENSOR SHALL BE TESTED.
3.FOR PROJECTS WITH MORE THAN SEVEN OCCUPANT SENSORS,
TESTING SHALL BE DONE FOR EACH UNIQUE COMBINATION OF
SENSOR TYPE AND SPACE GEOMETRY. WHERE MULTIPLES OF
EACH UNIQUE COMBINATION OF SENSOR TYPE AND SPACE
GEOMETRY ARE PROVIDED, NOT LESS THAN 10 PERCENT, BUT
IN NO CASE LESS THAN ONE, OF EACH COMBINATION SHALL BE
TESTED UNLESS THE CODE OFFICIAL REQUIRES A HIGHER
PERCENTAGE TO BE TESTED. WHERE 30 PERCENT OR MORE OF
THE TESTED CONTROLS FAIL, ALL REMAINING IDENTICAL
COMBINATIONS SHALL BE TESTED.
FOR OCCUPANT SENSOR CONTROLS TO BE TESTED, VERIFY THE
FOLLOWING:
3.1.WHERE OCCUPANT SENSOR CONTROLS INCLUDE STATUS
INDICATORS, VERIFY CORRECT OPERATION.
3.2.THE CONTROLLED LIGHTS TURN OFF OR DOWN TO THE
PERMITTED LEVEL WITHIN THE REQUIRED TIME.
3.3.FOR AUTO-ON OCCUPANT SENSOR CONTROLS, THE LIGHTS
TURN ON TO THE PERMITTED LEVEL WHEN AN OCCUPANT ENTERS
THE SPACE.
3.4.FOR MANUAL-ON OCCUPANT SENSOR CONTROLS, THE
LIGHTS TURN ON ONLY WHEN MANUALLY ACTIVATED.
3.5.THE LIGHTS ARE NOT INCORRECTLY TURNED ON BY
MOVEMENT IN ADJACENT AREAS OR BY HVAC OPERATION.
TIME-SWITCH CONTROLS:
WHERE TIME-SWITCH CONTROLS ARE PROVIDED, THE FOLLOWING
PROCEDURES SHALL BE PERFORMED:
1.CONFIRM THAT THE TIME-SWITCH CONTROL IS PROGRAMMED
WITH ACCURATE WEEKDAY, WEEKEND AND HOLIDAY
SCHEDULES.
2.PROVIDE DOCUMENTATION TO THE OWNER OF TIME-SWITCH
CONTROLS PROGRAMMING INCLUDING WEEKDAY, WEEKEND,
HOLIDAY SCHEDULES, AND SET-UP AND PREFERENCE
PROGRAM SETTINGS.
3.VERIFY THE CORRECT TIME AND DATE IN THE TIME SWITCH.
4.VERIFY THAT ANY BATTERY BACK-UP IS INSTALLED AND
ENERGIZED.
5.VERIFY THAT THE OVERRIDE TIME LIMIT IS SET TO NOT MORE
THAN 2 HOURS.
6.SIMULATE OCCUPIED CONDITION. VERIFY AND DOCUMENT THE
FOLLOWING:
6.1.ALL LIGHTS CAN BE TURNED ON AND OFF BY THEIR
RESPECTIVE AREA CONTROL SWITCH.
6.2.THE SWITCH ONLY OPERATES LIGHTING IN THE ENCLOSED
SPACE IN WHICH THE SWITCH IS LOCATED.
7.SIMULATE UNOCCUPIED CONDITION. VERIFY AND DOCUMENT
THE FOLLOWING:
7.1.NONEXEMPT LIGHTING TURNS OFF.
7.2.MANUAL OVERRIDE SWITCH ALLOWS ONLY THE LIGHTS IN THE
ENCLOSED SPACE WHERE THE OVERRIDE SWITCH IS LOCATED TO
TURN ON OR REMAIN ON UNTIL THE NEXT SCHEDULED SHUTOFF
OCCURS.
DAYLIGHT RESPONSIVE CONTROLS:
WHERE DAYLIGHT RESPONSIVE CONTROLS ARE PROVIDED, THE
FOLLOWING SHALL BE VERIFIED:
1.CONTROL DEVICES HAVE BEEN PROPERLY LOCATED, FIELD
CALIBRATED AND SET FOR ACCURATE SETPOINTS AND
THRESHOLD LIGHT LEVELS.
2.DAYLIGHT CONTROLLED LIGHTING LOADS ADJUST TO LIGHT
LEVEL SET POINTS IN RESPONSE TO AVAILABLE DAYLIGHT.
3.THE LOCATIONS OF CALIBRATION ADJUSTMENT EQUIPMENT
ARE READILY ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL.
DOCUMENTATION REQUIREMENTS:
DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING
CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA ARE TO
BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE
DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY.
DESCRIPTION OF OPERATION:
EXTERIOR SIGNAGE TO BE TURNED ON BY PHOTO
CELL. SIGNAGE WILL BE SWITCHED OFF BY TIME
SWITCH AT CLOSE.
COORDINATE WITH PIZZA HUT CONSTRUCTION
MANAGER ON TIME SETTINGS FOR INTERIOR
LIGHTING.
PC
PHOTO CELL
7