HomeMy WebLinkAboutE2 ELECTRICAL POWER ROOF PLAN.pdfF16-001
80"
B-19
2
6" BELOW
CEILING
GFCI
B-7
IGPANELBOARD 'A'
PANELBOARD 'B'
Z13-003
B-13
12"
A-29
S15-001
A-39
R2-007
E2-005
3
18"/GFCI
18"
A-35
13 Z3-001
A-9
2
A-25,27
P3-003
1
F11-001
F12-001
F13-001
F18-001
18"/IG
B-8
18"/GFCI
(PART)
B-12
18"
18"/IG
B-18
18"/IG
B-20
POS #5
POS #4
POS #6
60"
F15-002
U1-004
24"
C3-029
E3-005
42"
60"
U1-001
POS #2
B-16,IG
F15-002
16
60"
8
R3-011
A-23
C2-001
IG
U1-007
18"
A-33
B-22
18"
70"A-41
70"
E2
4
U1-002
POS #1
13
B-14
(PART)
12"
18"/IG B-12
U1-007
B-6
U1-009
U1-002
POS #3
U1-007
24"
98"/IG
84"
24"
P2-001
A-31
18"
U1-006
60"
B-9
(PART)
B-9
(PART)
IG
IG
R4-013
A-11,13
A-15,17
A-19,21
F15-002
60"
4
6
W1-001
EVAPORATOR
J B-5
(PART)
14
S
M
A-18
EVAPORATOR
J
J
B-5
(PART)
B-5
(PART)
15
4
A-14,16
30/2/15
W1-002
60" TYP OF (2)
F15-002
U1-004
24" TYP OF (2)
3
EF 5
B-2
f
12
B-4
(PART)
12
B-4
(PART)
12
B-4
(PART)
NEW ROOF MOUNTED
FREEZER CONDENSER
REF: SHEET A3 FOR
EQUIPMENT PLATFORM
7
A-3
7
9
A-2,4,6
A-8,10,12
10
NEW ROOF MOUNTED
COOLER CONDENSER
REF: SHEET A3 FOR
EQUIPMENT PLATFORM
A-1
11
A-26,28,30
WP/GFCI
A-37
SF
1
EF
1
EF
2
RTU
2
RTU
1
RTU
3
7
A-5
WP/GFCI
A-37
WP/GFCI
A-37
A-32,34,36
A-20,22,24
11
11
60/3/35
NEMA-3R
60/3/30
NEMA-3R
60/3/35
NEMA-3R
SHEET NUMBER
RE
V
I
S
I
O
N
S
:
DA
T
E
:
JO
B
N
O
:
DR
A
W
N
:
CH
E
C
K
E
D
:
AC
G
#
:
06
/
2
0
/
1
9
21
7
5
AA
,
K
K
,
S
O
AR
,
C
F
19
2
0
1
9
1
14
8
1
7
W
e
s
t
9
5
t
h
S
t
r
e
e
t
L
e
n
e
x
a
,
K
a
n
s
a
s
6
6
2
1
5
P
9
1
3
3
2
2
5
1
5
0
F
9
1
3
3
2
2
5
1
5
5
ww
w
.
A
c
e
r
t
u
s
G
r
o
u
p
.
c
o
m
FRANCHISEE
7300 W. 129TH STREET
OVERLAND PARK, KANSAS
66213
PHONE: (913) 327-5555
FAX: (913) 327-5850
16
3
W
M
A
I
N
S
T
.
S
U
I
T
E
T
B
D
RE
X
B
U
R
G
,
I
D
A
H
O
PI
Z
Z
A
H
U
T
#
2
1
7
5
06/20/19
E2
ELECTRICAL ROOF PLAN 1/4" = 1'-0"2
EL
E
C
T
R
I
C
A
L
PO
W
E
R
/
R
O
O
F
P
L
A
N
NOTE:
ELECTRICAL CONTRACTOR IS RESPONSIBLE
FOR ALL POS WIRING AND ALL TELEPHONE
WIRING. COORDINATE WITH NPC FACILITIES/
PROJECT MANAGER.
6GENERAL NOTES
4
SPECIAL SYMBOL LEGEND 1
1.FIELD VERIFY ALL ELECTRICAL WORK WITH OWNER BEFORE START OF PROJECT.
2.THE FINAL LOCATION OF EMERGENCY LIGHTING TO BE COORDINATED WITH LOCAL FIRE MARSHAL.
3.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND CIRCUIT TO THE PIZZA HUT SIGN ON THE BUILDING TOWER.
COORDINATE WITH NPC FACILITIES/PROJECT MANAGER.
4.REFER TO SHEET E1 FOR ELECTRICAL RISER DIAGRAM AND PANELBOARD SCHEDULES.
5.ALL TELEPHONES TO BE WALL MOUNTED.
6.MOUNT ALL RECEPTACLES AND TELEPHONE/DATA OUTLETS AT 18" AFF UNLESS DIRECTED OTHERWISE ON PLAN.
5KEY NOTES
ELEVATION WINGSTREET LINE
70"70"
PREP WALL SYSTEM
FRYER HOOD
COMPACT WORK
TOP FREEZER ON
3" CASTERS
GAS OPEN FRYER
FINISHING
STATION
KITCHEN
PRINTER
18"
TO PATCH PANEL
18"
REFRIGERATOR
HOT HOLD
DISHWASHER
PROOFER2
3
1 LOCAL WP 1P/20A CIRC BREAKER OR DISC SWITCH MEANS. MTG. @ 18"
AFF. AND SEALTITE FLEX CONDUIT TO UNIT.
208V, 2P/16A. PROVIDE NEMA L6-20R.
SPECIAL OUTLETS
120V, 1P/19.3A/3 WIRE RECEPTACLE, NEMA L5-30R.
OVENS4 208V, 2P/4.5A. PROVIDE NEMA L6-20R (VERIFY W/
MANUFACTURER)
HOOD CONTROL PANEL. COORDINATE ALL REQUIREMENTS INCLUDING INSTALLATION, POWER, CIRCUIT CONTROLS AND
LOCATION WITH CONSTRUCTION MANAGER/VENDOR PRIOR TO ROUGH-IN. COORDINATE CIRCUITS CONTROLLED WITH
PANELBOARD SCHEDULES.
PHONE CONTROL SYSTEM ON 24"x48"x3/4" AC PLYWOOD WITH EASED EDGES. PAINT PLYWOOD ONLY TO MATCH WALL.
COORDINATE WITH TELEPHONE VENDOR. VERIFY LOCATION WITH NPC FACILITIES/PROJECT MANAGER. EXTEND EXISTING
TELEPHONE CONDUIT TO NEW LOCATION AS REQUIRED.
PROVIDE IN USE WATER TIGHT COVER @ DISHWASHER RECEPTACLE.
PROVIDE WATER TIGHT J-BOX @ 72" A.F.F FOR DRAIN HEAT TAPE. (HARD WIRE)
DISCONNECT FURNISHED BY MANUFACTURER. VERIFY EXACT LOCATION. CIRCUIT AS SHOWN. CONTROL EF-3 ALONG
WITH RESTROOM LIGHTS WITH RESTROOM LIGHT SWITCH, SWITCH "f".
PROVIDE (3)#12 AND (1)#12G IN 3/4" CONDUIT FOR OVEN. CAP NEUTRAL WIRE IF NOT USED. VERIFY NEMA
CONFIGURATION OF RECEPTACLE WITH OVEN PLUG AS REQUIRED.
DISCONNECT FURNISHED BY MANUFACTURER FOR HVAC EQUIPMENT. VERIFY EXACT LOCATION. CIRCUIT AS SHOWN.
INSTALL DATA AND RECEPTACLE OUTLET STACKED VERTICALLY DIRECTLY UNDER PHONE DATA OUTLET.
PROVIDE 30A, 3P NEMA 3R, FUSED DISCONNECT WITH 20A FUSE FOR WALK-IN FREEZER.
PROVIDE 30A, 3P NEMA 3R, FUSED DISCONNECT WITH 20A FUSE FOR WALK-IN COOLER.
PROVIDE LOCAL DISCONNECT FOR MECHANICAL EQUIPMENT. COORDINATE REQUIREMENTS WITH MECHANICAL
CONTRACTOR.
RECEPTACLES MOUNTED AT CEILING FOR SHOW WINDOW POWER; PER NEC REQUIREMENTS.
INSTALL CONDUIT, CONDUCTORS AND OUTLET BOXES SO THAT THEY ARE HIDDEN/OUT OF VIEW OF CUSTOMERS.
CONDUIT, CONDUCTORS AND OUTLET BOXES MAY BE EXPOSED UNDER COUNTER TOP IF REQUIRED.
PROVIDE DISCONNECT FOR COOLER EVAPORATOR. COORDINATE ALL CIRCUITING AND CONNECTIONS WITH EVAPORATOR
AND CONDENSER WITH MANUFACTURER. CONTRACTOR IS TO PROVIDE ALL REQUIRED POWER AND LOW VOLTAGE
CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM.
PROVIDE DISCONNECT FOR FREEZER EVAPORATOR AS REQUIRED BY MANUFACTURER. COORDINATE ALL CIRCUITING AND
CONNECTIONS WITH EVAPORATOR AND CONDENSER WITH MANUFACTURER. CONTRACTOR IS TO PROVIDE ALL REQUIRED
POWER AND LOW VOLTAGE CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM.
RECEPTACLE SHALL BE MOUNTED 6" BELOW CEILING ON SOFFIT ABOVE KITCHEN EQUIPMENT.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ELECTRICAL POWER PLAN 1/4" = 1'-0"3