HomeMy WebLinkAboutE2 ELECTRICAL POWER ROOF PLAN.pdfF16-001 80" B-19 2 6" BELOW CEILING GFCI B-7 IGPANELBOARD 'A' PANELBOARD 'B' Z13-003 B-13 12" A-29 S15-001 A-39 R2-007 E2-005 3 18"/GFCI 18" A-35 13 Z3-001 A-9 2 A-25,27 P3-003 1 F11-001 F12-001 F13-001 F18-001 18"/IG B-8 18"/GFCI (PART) B-12 18" 18"/IG B-18 18"/IG B-20 POS #5 POS #4 POS #6 60" F15-002 U1-004 24" C3-029 E3-005 42" 60" U1-001 POS #2 B-16,IG F15-002 16 60" 8 R3-011 A-23 C2-001 IG U1-007 18" A-33 B-22 18" 70"A-41 70" E2 4 U1-002 POS #1 13 B-14 (PART) 12" 18"/IG B-12 U1-007 B-6 U1-009 U1-002 POS #3 U1-007 24" 98"/IG 84" 24" P2-001 A-31 18" U1-006 60" B-9 (PART) B-9 (PART) IG IG R4-013 A-11,13 A-15,17 A-19,21 F15-002 60" 4 6 W1-001 EVAPORATOR J B-5 (PART) 14 S M A-18 EVAPORATOR J J B-5 (PART) B-5 (PART) 15 4 A-14,16 30/2/15 W1-002 60" TYP OF (2) F15-002 U1-004 24" TYP OF (2) 3 EF 5 B-2 f 12 B-4 (PART) 12 B-4 (PART) 12 B-4 (PART) NEW ROOF MOUNTED FREEZER CONDENSER REF: SHEET A3 FOR EQUIPMENT PLATFORM 7 A-3 7 9 A-2,4,6 A-8,10,12 10 NEW ROOF MOUNTED COOLER CONDENSER REF: SHEET A3 FOR EQUIPMENT PLATFORM A-1 11 A-26,28,30 WP/GFCI A-37 SF 1 EF 1 EF 2 RTU 2 RTU 1 RTU 3 7 A-5 WP/GFCI A-37 WP/GFCI A-37 A-32,34,36 A-20,22,24 11 11 60/3/35 NEMA-3R 60/3/30 NEMA-3R 60/3/35 NEMA-3R SHEET NUMBER RE V I S I O N S : DA T E : JO B N O : DR A W N : CH E C K E D : AC G # : 06 / 2 0 / 1 9 21 7 5 AA , K K , S O AR , C F 19 2 0 1 9 1 14 8 1 7 W e s t 9 5 t h S t r e e t L e n e x a , K a n s a s 6 6 2 1 5 P 9 1 3 3 2 2 5 1 5 0 F 9 1 3 3 2 2 5 1 5 5 ww w . A c e r t u s G r o u p . c o m FRANCHISEE 7300 W. 129TH STREET OVERLAND PARK, KANSAS 66213 PHONE: (913) 327-5555 FAX: (913) 327-5850 16 3 W M A I N S T . S U I T E T B D RE X B U R G , I D A H O PI Z Z A H U T # 2 1 7 5 06/20/19 E2 ELECTRICAL ROOF PLAN 1/4" = 1'-0"2 EL E C T R I C A L PO W E R / R O O F P L A N NOTE: ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL POS WIRING AND ALL TELEPHONE WIRING. COORDINATE WITH NPC FACILITIES/ PROJECT MANAGER. 6GENERAL NOTES 4 SPECIAL SYMBOL LEGEND 1 1.FIELD VERIFY ALL ELECTRICAL WORK WITH OWNER BEFORE START OF PROJECT. 2.THE FINAL LOCATION OF EMERGENCY LIGHTING TO BE COORDINATED WITH LOCAL FIRE MARSHAL. 3.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND CIRCUIT TO THE PIZZA HUT SIGN ON THE BUILDING TOWER. COORDINATE WITH NPC FACILITIES/PROJECT MANAGER. 4.REFER TO SHEET E1 FOR ELECTRICAL RISER DIAGRAM AND PANELBOARD SCHEDULES. 5.ALL TELEPHONES TO BE WALL MOUNTED. 6.MOUNT ALL RECEPTACLES AND TELEPHONE/DATA OUTLETS AT 18" AFF UNLESS DIRECTED OTHERWISE ON PLAN. 5KEY NOTES ELEVATION WINGSTREET LINE 70"70" PREP WALL SYSTEM FRYER HOOD COMPACT WORK TOP FREEZER ON 3" CASTERS GAS OPEN FRYER FINISHING STATION KITCHEN PRINTER 18" TO PATCH PANEL 18" REFRIGERATOR HOT HOLD DISHWASHER PROOFER2 3 1 LOCAL WP 1P/20A CIRC BREAKER OR DISC SWITCH MEANS. MTG. @ 18" AFF. AND SEALTITE FLEX CONDUIT TO UNIT. 208V, 2P/16A. PROVIDE NEMA L6-20R. SPECIAL OUTLETS 120V, 1P/19.3A/3 WIRE RECEPTACLE, NEMA L5-30R. OVENS4 208V, 2P/4.5A. PROVIDE NEMA L6-20R (VERIFY W/ MANUFACTURER) HOOD CONTROL PANEL. COORDINATE ALL REQUIREMENTS INCLUDING INSTALLATION, POWER, CIRCUIT CONTROLS AND LOCATION WITH CONSTRUCTION MANAGER/VENDOR PRIOR TO ROUGH-IN. COORDINATE CIRCUITS CONTROLLED WITH PANELBOARD SCHEDULES. PHONE CONTROL SYSTEM ON 24"x48"x3/4" AC PLYWOOD WITH EASED EDGES. PAINT PLYWOOD ONLY TO MATCH WALL. COORDINATE WITH TELEPHONE VENDOR. VERIFY LOCATION WITH NPC FACILITIES/PROJECT MANAGER. EXTEND EXISTING TELEPHONE CONDUIT TO NEW LOCATION AS REQUIRED. PROVIDE IN USE WATER TIGHT COVER @ DISHWASHER RECEPTACLE. PROVIDE WATER TIGHT J-BOX @ 72" A.F.F FOR DRAIN HEAT TAPE. (HARD WIRE) DISCONNECT FURNISHED BY MANUFACTURER. VERIFY EXACT LOCATION. CIRCUIT AS SHOWN. CONTROL EF-3 ALONG WITH RESTROOM LIGHTS WITH RESTROOM LIGHT SWITCH, SWITCH "f". PROVIDE (3)#12 AND (1)#12G IN 3/4" CONDUIT FOR OVEN. CAP NEUTRAL WIRE IF NOT USED. VERIFY NEMA CONFIGURATION OF RECEPTACLE WITH OVEN PLUG AS REQUIRED. DISCONNECT FURNISHED BY MANUFACTURER FOR HVAC EQUIPMENT. VERIFY EXACT LOCATION. CIRCUIT AS SHOWN. INSTALL DATA AND RECEPTACLE OUTLET STACKED VERTICALLY DIRECTLY UNDER PHONE DATA OUTLET. PROVIDE 30A, 3P NEMA 3R, FUSED DISCONNECT WITH 20A FUSE FOR WALK-IN FREEZER. PROVIDE 30A, 3P NEMA 3R, FUSED DISCONNECT WITH 20A FUSE FOR WALK-IN COOLER. PROVIDE LOCAL DISCONNECT FOR MECHANICAL EQUIPMENT. COORDINATE REQUIREMENTS WITH MECHANICAL CONTRACTOR. RECEPTACLES MOUNTED AT CEILING FOR SHOW WINDOW POWER; PER NEC REQUIREMENTS. INSTALL CONDUIT, CONDUCTORS AND OUTLET BOXES SO THAT THEY ARE HIDDEN/OUT OF VIEW OF CUSTOMERS. CONDUIT, CONDUCTORS AND OUTLET BOXES MAY BE EXPOSED UNDER COUNTER TOP IF REQUIRED. PROVIDE DISCONNECT FOR COOLER EVAPORATOR. COORDINATE ALL CIRCUITING AND CONNECTIONS WITH EVAPORATOR AND CONDENSER WITH MANUFACTURER. CONTRACTOR IS TO PROVIDE ALL REQUIRED POWER AND LOW VOLTAGE CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM. PROVIDE DISCONNECT FOR FREEZER EVAPORATOR AS REQUIRED BY MANUFACTURER. COORDINATE ALL CIRCUITING AND CONNECTIONS WITH EVAPORATOR AND CONDENSER WITH MANUFACTURER. CONTRACTOR IS TO PROVIDE ALL REQUIRED POWER AND LOW VOLTAGE CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM. RECEPTACLE SHALL BE MOUNTED 6" BELOW CEILING ON SOFFIT ABOVE KITCHEN EQUIPMENT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ELECTRICAL POWER PLAN 1/4" = 1'-0"3