HomeMy WebLinkAboutROOF PLAN - Pizza Hut - Tenant RemodelSCREWS WITH
NEOPRENE WASHERS
@ 12" O.C.
ONE PIECE 18 GA. GALV. SHEET
PREFORMED CANT MTL. CAP ON 3/4" PLYWD. &
STRIP TREATED 2x8'S @ 12" ON CENTER
PATCH & MATCH
EXIST. MEMBRANE
ROOF
2x BLOCKING VERIFY SIZE
WITH MECH. CONTRACTOR
EQUIPMENT
RE: MECH.
SLOPE CAP
TO DRAIN
NOTE: COORDINATE ALL ROOF REWORK WITH LANDLORD.
ROOFING CONTRACTOR TO MAINTAIN ROOF WARRANTY
NOTE: GC TO FIELD VERIFY SLOPE OF ROOF. SLOPED CURBS
WILL BE REQUIRED.
STRIP IN WITH TWO
PLIES OF FELT —
SET FLANGE IN
MASTIC -PRIME
FLANGE BEFORE
STRIPPING
2.5 LBS. ROLLED LEAD
FLASHING EXTENDED 1" DOWN
INTO PIPE
MASTIC AT EDGES OF
MEMBRANE
NOTE: INSTALL AND SEAL ROOF JACKS TO THE EXISTING
ROOF TO PREVENT LEAKAGE AT ALL ROOF PENETRATIONS
NOTE: CURBS FOR RTU'S AND
FANS FURNISHED AND INSTALLED
BY CONTRACTOR
WOOD NAILER -NOMINAL 2" X 4"
METAL FRAME
SEALING MATERIAL CONTINUOUS
FLASHING RECEIVER
COUNTERFLASHING
FASTENERS AT 8" O.C.
EXISTING MEMBRANE
ROOFING
NEW BASE FLASHING - AS REQUIRED
TO MAINTAIN ROOF WARRANTY
(TYP.)
INSULATION
FIBER CANT STRIP
-SET IN BITUMEN
NEW STRUCTURAL HEADERS
AS REQUIRED - GEN
CONTRACTOR COORDINATE
1. ALL WORK SHALL COMPLY WITH NRCA ROOFING AND
WATERPROOFING MANUAL, COORDINATE LOCATION OF OPENINGS
WITH MECHANICAL CONTRACTOR, PROVIDE ADDITIONAL
STRUCTURAL SUPPORT AS REQUIRED TO SUPPORT NEW LOADS.
2. SUPPLY FAN & EXHAUST FAN ROOF CURBS PROVIDED BY OWNER
AND INSTALLED BY GENERAL CONTRACTOR, GENERAL CONTRACT
SHALL PROVIDE FLASHING AND COUNTER FLASHING, VERIFY SIZE
AND LOCATION WITH MECH. CONTRACTOR.
3. GENERAL CONTRACTOR SHALL PROVIDE RAISED PLATFORM WITH
ONE PIECE 18 GAUGE GALVANIZED SHEET METAL CAP FOR
CONDENSING UNITS. VERIFY SIZE AND LOCATION WITH MECH.
CONTRACTOR.
4. PATCH AND MATCH EXISTING ROOF MEMBRANE AT NEW ROOF
PENETRATIONS AND CURBS & TO PROVIDE WEATHER-PROOF
BARRIER. MAINTAIN EXISTING ROOF WARRANTY. COORDINATE ALL
ROOF REWORK AND VERIFY EXACT REQUIREMENTS WITH LANDLOI
5. G.C. TO SEAL ALL ROOF PENETRATIONS WATER TIGHT, REFER TO
ARCHITECTURAL FOR DETAIL.
6. FRESH AIR INTAKE SHALL BE A MINIMUM OF 10'-0" AWAY FROM
BUILDING EXHAUST, FLUES, OR PLUMBING VENTS.
7. MECH. CONTRACTOR TO VERIFY THAT NEW EQUIPMENT (FANS, ETC.)
COMPLY WITH AVAILABLE POWER SOURCE. COORDINATE WITH
ELECTRICIAN, GEN CONTRACTOR.
8. MAINTAIN MINIMUM REQUIRED DISTANCES BETWEEN EXHAUST AND
SUPPLY FANS, MECH. CONTRACTOR TO COORDINATE
9. VERIFY LOCATION OF ALL UNITS ON ROOF WITH OWNER. OBTAIN
APPROVAL FROM NPC FACILITIES/PROJECT MANAGER AND OWNER
REGARDING LOCATION AND LOADING OF NEW EQUIPMENT ON ROOF
BEFORE START OF PROJECT.
10. OBTAIN APPROVAL FROM LANDLORD'S LICENSED STRUCTURAL
ENGINEER REGARDING LOCATION AND LOADING OF NEW EQUIPMEN
AND OPENINGS ON ROOF SUPPORT STRUCTURE BELOW PRIOR TO
START OF ANY WORK ON THE ROOF
11. COORDINATE ALL ROOF WORK WITH LANDLORDS ROOFING
CONTRACTOR TO MAINTAIN WARRANTY
MECHANICAL PLATFORM EQUIPMENT11 1/2"=1'-0"1 4 I VENT/PIPE FLASHING DETAIL11 1/2"=1'-0"1 3 1 FLASHING AT CURB11 1/2"=1'-0111 2 1 ROOF GENERAL NOTES I
I I III
I I III
DEMISING WALL—'
EXTERIOR WALL
I L------- I I /BELOW
-------------------------------------�
--------------II
EXTERIOR WALL I I
BELOW I NEW ROOFTOP UNIT RTU -3 AND NEW ROOF MOUNTED HOOD III
PRE -MANUFACTURED ROOF CURB RH-1 AND ROOF CURB III
I I III
I I nl
II �
DOOR BELOW / III WINDOW BELOW
I I VN III
NEW ROOFTOP UNIT RTU -2 AND M
I / PRE- MANUFACTURED ROOF CURB III
uI
I I NEW ROOF MOUNTED III
EXHAUST FAN EF -2 WITH III
ROOF CAP AND ROOF CURB W
II � II
II II
I I I L
� EXTERIOR WALL
BELOW
4' II Ir/
EXTERIOR WALL
BELOW
NEW ROOF MOUNTED III
SUPPLY FAN SF -1 WITH
NEW ROOF MOUNTED ROOF CAP AND ROOF CURB
EXHAUST FAN EF -1 WITH
DOOR BELOW
ROOF CAP AND ROOF CURB I I \
I I III
I I III
I I 111
` — r EXTERIOR WALL
BELOW
r
II II
NEW ROOF MOUNTED I I
M FREEZER/COOLER �1
III
CONDENSER
EQUIPMENT PLATFORM III
III (SEE 4-A7) III
III III
III NEW ROOFTOP UNIT RTU -1 AND III
WINDOW BELOW PRE -MANUFACTURED ROOF CURB WINDOW BELOW
SII II�
III III
III III
III III
EXTERIOR WALL
EXTERIOR WALL BELOW
BELOW l I — — — — — I
JE EEE
L J
LJ LL JJ
EXTERIOR WALL EXTERIOR WALL
BELOW BELOW
ROOF PLAN
(f)
N
cb
N X 2
0
Z Z Y
w 3 V
O O U
Q
J
IL
LL_
0
0
s
FRANCHISEE
international
7300 W. 129TH STREET
OVERLAND PARK, KANSAS
66213
PHONE: (913) 327-5555
FAX: (913) 327-5850
d'
L
L.LJ
r �
N :D
N
0 O
=a
zQo
N � �
N
14) x
L(0L L
w
4-J
U
U o
L_ rn
Qv
N `^
t1A
m
ro
ca
� N
N
L ?�timo
O N Q1
..�, `J N N N
n
LT F N
1 m C
C Ln 0 x
v` C 00CL
4WBRUWDIGE
rn
N
n!
�
SHEET NUMBER
N
Z A7
a
N