Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FLOOR PLAN - Pizza Hut - Tenant Remodel
TYPICAL INTERIOR WALL: 2X4 WOOD STUDS @ 16" O.C. W/ 5/8" GYPSUM BOARD EACH SIDE. (2X6 WOOD STUDS AT PLUMBING WALLS U.O.N.) SEE A6 _} EXISTING WALLS TO REMAIN TYPICAL HOOD WALL: 3 5/8" 25 GAUGE METAL STUDS @ 16" O.C. W/ 5/8" GYPSUM BOARD EACH SIDE. (6" METAL STUDS AT PLUMBING WALLS U.O.N.) SEE A6 FLOOR PLAN DIMENSIONS A. ALL DIMENSIONS ARE TO FACE OF STUD AT NEW WALLS, UNLESS OTHERWISE NOTED B. DIMENSIONS ARE FROM FACE OF FINISHED MATERIAL AT EXISTING WALLS AND NEW FIRE RATED TENANT DEMISING WALL, UNLESS OTHERWISE NOTED. C. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INTERIOR WALL FRAMING. D. FIELD VERIFY ALL DIMENSIONS PARTITION E. PROVIDE PROPER FIRE RETARDANT BLOCKING AT ALL RECESSED AND WALL MOUNTED FIXTURES/EQUIPMENT. FINISH SUBSTRATES F. PROVIDE 5/8" THICK CEMENTITIOUS BOARD FROM FLOOR SLAB TO 12" A.F.F. G. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. H. GYPSUM BOARD SHALL EXTEND 6" ABOVE SUSPENDED CEILING. 20 ELECTRICAL PANELS. RE: ELECTRICAL FOR MORE INFORMATION. 21 INSTALL OWNER FURNISHED STAINLESS STEEL PANELS (18 GAUGE, #3 FINISH) OVER 5/8" TYPE "X" /CEMENTITOUS BOARD. PANELS WILL EXTEND A MIN. OF 1" ABOVE CEILING AND DOWN TO 1" BELOW TOP OF BASE TILE. NO EXPOSED SCREWS/ATTACHMENTS. 22 EXISTING STOREFRONT DOOR AND HARDWARE TO REMAIN EXCEPT AS NOTED ELSEWHERE IN THESE DOCUMENTS. GENERAL CONTRACTOR TO INSPECT DOOR FOR PROPER OPERATION AND REPAIR/REPLACE HARDWARE AS NECESSARY TO ENSURE COMPLIANCE WITH ACCESSIBILITY AND EGRESS REQUIREMENTS. 23 EXISTING EXTERIOR WALL. PROVIDE 5/8" TYPE 'X' GYP. BD. ON INTERIOR, TYP. (SEE SHEET A3.1) WALL LEGEND I FLOOR PLAN NOTES1 KEY NOTES .. S -F," I FASF I INF NOTE: TREAT ALL SOIL EXPOSED DURING TRENCHING AND/OR ALL SOIL NOT CONNECTED BY AN EXISTING CONCRETE SLAB AT THE START OF CONSTRUCTION WITH TERMITE TREATMENT AS OPTIONAL BY OWNER #3 X V-6" LONG @ 12"NEW SLAB, MATCH OC DRILLER & EPDXIED EXISTING DEPTH (4" 6" INTO EXSTG SLAB MIN) #3@12" EXISTING SLAB OC EW EXISTING TO REMAIN SLAB TO -s REMAIN VAPOR BARRIER, MATCH SUBGRADE: SELECT FILL fff—_I COMPACTED TO 95% II —III— EXISTG (6 MIL MIN) — DRY DENSITY (ASTM _III D-698), MOISTURE _ lL= L UTILITY LINES, REFER CONDITIONED TO 0° ° o 0 MEP DWGS 3% OF OPTIMUM FILTER FABRIC MOISTURE, LESS THAN ° 15 P.I„ LIQUID LIMIT a ° ° �y ° GRAVEL FILL, NOT TO LESS THAN 35. PERFORM ° �b °�o�� EXTEND TO WITHIN 12" IN 8" LIFTS. OF BUILDING PERIMETER SANITARY SEWER LINE, REF MEP DWGS TRENCHING DETAIL I B (i) 1/4"-1'-0" I A cl n � N06 X 2 c _ = Y DLLJ O' G U Q J CL O J Li. 1 FRANCHISEE 41117 international 7300 W. 129TH STREET OVERLAND PARK, KANSAS 66213 PHONE: (913) 327-5555 FAX: (913) 327-5850 u ) W � H N N o I—cn= a = z o a Q m � N m N M x U i U O a Y W N m A � � N � N N c)) ul �o ML 3 x1010 W O N T W d N N N CLn r1 N C O L — O X 00 0 CL LICENSED ARGHITECT AR -984287 sv f �MARC W. BRUNDIGSTr?TE OF IDAH SHEET NUMBER z Al 0 N LL TYPE "1" HOOD WITH ANSUL SYSTEM 14 NEW BACKFLOW PREVENTER O PROVIDE A SIGN STATING "THIS DOOR TO REMAIN UNLOCKED DURING 15 O INSTALL OWNER FURNISHED STAINLESS STEEL PANELS (18 GAUGE, #3 NORMAL BUSINESS HOURS" {1" HIGH MIN. LETTERING USING "X" CONTRASTING COLORS). FINISH) OVER 5/8" TYPE CEMENTITIOUS BOARD. STAINLESS STEEL PANELS WILL EXTEND A MIN. OF 18" ABOVE TOP OF HOOD, 18" AT NEW HAND SINK EACH SIDE OF EQUIPMENT, AND DOWN TO 1" BELOW TOP OF BASE ® NEW MOP SINK TILE. NO EXPOSED SCREWS/ATTACHMENTS. NEW TANK WATER HEATER 1g INSTALL OWNER FURNISHED STAINLESS STEEL SKIRT FROM WINGSTREET FRYER HOOD TO CEILING. © INSTALL NEW WATER CLOSET, LAVATORY, GRAB BARS, TOILET PAPER DISPENSER, SANITARY NAPKIN DISPOSAL, PAPER TOWEL DISPENSER AND 17 EXISTING DOOR AND HARDWARE TO REMAIN. GENERAL CONTRACTOR TO MIRROR PER CODE REQUIREMENT. (SEE 6, 7, 8, 10-A4) PROVIDE FIRE INSPECT DOOR FOR PROPER OPERATION AND REPAIR/REPLACE RETARDANT TREATED WOOD AT ALL BLOCKING IN WALL. HARDWARE AS NECESSARY TO ENSURE COMPLIANCE WITH ACCESSIBILITY AND EGRESS REQUIREMENTS. SPLASH GUARD (SEE DETAIL 4-A6) 18 EXISTING DEMISING WALL. PROVIDE 5/8" TYPE TYPE 'X' GYP. BD. ® NEW TELEPHONE BOARD TENANT SIDE ONLY. 90 FRONT COUNTER (2'-8" x 7'-0"), SUPPLIED BY OWNER AND 19 O PROVIDE BACKING IN WALL FOR WALL MOUNTED EQUIPMENT ITEMS INSTALLED BY GENERAL CONTRACTOR. AS FOLLOWS: 10 INSTALL PROPER BLOCKING/BACKER ROD AND SEALANT "VERMIN TIGHT" F21-001 K11-00 K16-001 K18-005 BETWEEN WALK-IN COOLER/FREEZER AND ADJACENT WALL SURFACES. K20-005 K13-005 K11-001 11 MOP HANGER ON WALL COORDINATE EQUIPMENT ITEM NUMBERS WITH SHEET A2 AND A2.1 12 NOT USED BACKING SHOWN AS: — — — — — — 13 NOT USED 20 ELECTRICAL PANELS. RE: ELECTRICAL FOR MORE INFORMATION. 21 INSTALL OWNER FURNISHED STAINLESS STEEL PANELS (18 GAUGE, #3 FINISH) OVER 5/8" TYPE "X" /CEMENTITOUS BOARD. PANELS WILL EXTEND A MIN. OF 1" ABOVE CEILING AND DOWN TO 1" BELOW TOP OF BASE TILE. NO EXPOSED SCREWS/ATTACHMENTS. 22 EXISTING STOREFRONT DOOR AND HARDWARE TO REMAIN EXCEPT AS NOTED ELSEWHERE IN THESE DOCUMENTS. GENERAL CONTRACTOR TO INSPECT DOOR FOR PROPER OPERATION AND REPAIR/REPLACE HARDWARE AS NECESSARY TO ENSURE COMPLIANCE WITH ACCESSIBILITY AND EGRESS REQUIREMENTS. 23 EXISTING EXTERIOR WALL. PROVIDE 5/8" TYPE 'X' GYP. BD. ON INTERIOR, TYP. (SEE SHEET A3.1) WALL LEGEND I FLOOR PLAN NOTES1 KEY NOTES .. S -F," I FASF I INF NOTE: TREAT ALL SOIL EXPOSED DURING TRENCHING AND/OR ALL SOIL NOT CONNECTED BY AN EXISTING CONCRETE SLAB AT THE START OF CONSTRUCTION WITH TERMITE TREATMENT AS OPTIONAL BY OWNER #3 X V-6" LONG @ 12"NEW SLAB, MATCH OC DRILLER & EPDXIED EXISTING DEPTH (4" 6" INTO EXSTG SLAB MIN) #3@12" EXISTING SLAB OC EW EXISTING TO REMAIN SLAB TO -s REMAIN VAPOR BARRIER, MATCH SUBGRADE: SELECT FILL fff—_I COMPACTED TO 95% II —III— EXISTG (6 MIL MIN) — DRY DENSITY (ASTM _III D-698), MOISTURE _ lL= L UTILITY LINES, REFER CONDITIONED TO 0° ° o 0 MEP DWGS 3% OF OPTIMUM FILTER FABRIC MOISTURE, LESS THAN ° 15 P.I„ LIQUID LIMIT a ° ° �y ° GRAVEL FILL, NOT TO LESS THAN 35. PERFORM ° �b °�o�� EXTEND TO WITHIN 12" IN 8" LIFTS. OF BUILDING PERIMETER SANITARY SEWER LINE, REF MEP DWGS TRENCHING DETAIL I B (i) 1/4"-1'-0" I A cl n � N06 X 2 c _ = Y DLLJ O' G U Q J CL O J Li. 1 FRANCHISEE 41117 international 7300 W. 129TH STREET OVERLAND PARK, KANSAS 66213 PHONE: (913) 327-5555 FAX: (913) 327-5850 u ) W � H N N o I—cn= a = z o a Q m � N m N M x U i U O a Y W N m A � � N � N N c)) ul �o ML 3 x1010 W O N T W d N N N CLn r1 N C O L — O X 00 0 CL LICENSED ARGHITECT AR -984287 sv f �MARC W. BRUNDIGSTr?TE OF IDAH SHEET NUMBER z Al 0 N LL