HomeMy WebLinkAboutTITLE SHEET & INDEX - Pizza Hut - Tenant RemodelPROJECT GENERAL NOTES
SYMBOLS
LEGAL JURISDICTION: CITY OF REXBURG, ID
SHEET INDEX
TITLE
APPLICABLE CODES: BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE
1. FIELD VERIFY ALL DIMENSIONS.
ROOM NAME OX DOOR NUMBER
2.
FIELD VERIFY EXISTING CONDITIONS. REMOVE ALL ABANDONED CONDUIT, PIPING, HVAC
T1
TITLE SHEET AND DRAWING INDEX
DUCT, LIGHTING, OUTLETS AND EQUIPMENT. PATCH OR REPAIR FLOOR AND WALLS
PLUMBING CODE: 2017 IDAHO PLUMBING CODE
THAT ARE DAMAGED IN THE PROCESS OF DEMOLITION.
X
O WINDOW NUMBER
3.
REPLACE OR REPAIR DAMAGED, DETERIORATED OR UNSUITABLE SUBSTRATES AS
DIRECTION OF ELEVATION
MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE
ARCHITECTURAL
REQUIRED TO RECEIVE NEW WALL FINISHES AS SCHEDULED.
XXXCX—
SHEET NUMBER ELEVATION NUMBER
X EXTERNAL WALL FINISH
O
FIRE CODE: 2015 INTERNATIONAL FIRE CODE
4.
NOT USED.
X
NUMBER
Al
FLOOR PLAN
ELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODE
5.
NOT USED.
SHEAR WALL
D
A2
EQUIPMENT PLAN
6.
CUT, REMOVE AND REPLACE EXISTING CONCRETE SLAB AS REQUIRED FOR INSTALLATION OF
� DIRECTION OF SECTION
TYPE
ACCESSIBILITY CODE: 2009 ACCESSIBILITY CODE
NEW UNDERFLOOR UTILITIES. CONSTRUCT BACK BASE MATERIAL AND SLAB TO MATCH
EXISTING ADJACENT CONSTRUCTION AFTER UNDERSLAB UTILITIES HAVE BEEN INSTALLED.
X_XA2.1
SECTION TAIL
FRAMING HEADER
NUMBER
ENERGY CODE: 2015 INTERNATIONAL ENERGY CONSERVATION CODE
EQUIPMENT SCHEDULE
A3
FINISH PLAN
7.
ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND
SHEET NUMBER
LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS.
SECTION NUMBER
All
FINISH AND DOOR SCHEDULES
KEYNOTE
8.
ALL REMODELED BUILDING ELEMENTS INCLUDED AS PART OF THIS PROJECT SHALL
A4
INTERIOR ELEVATIONS AND DETAILS
COMPLY WITH THE MOST CURRENT EDITION OF BUILDING CODE, AND LOCAL CODE.
@--SHEET
DETAIL NUMBER
A5
REFLECTED CEILING PLAN
9.
PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, CONTRACTOR SHALL VERIFY
NUMBER
<> EQUIPMENT ROUGH
-IN CONNECTION,
A6
INTERIOR WALL SECTIONS AND DETAILS
GROSS LEASE AREA: 1,566 SQ. FT.
EXISTENCE AND LOCATION OF ALL EXISTING ABOVE AND BELOW GRADE UTILITIES,
NUMBER
INCLUDING SANITARY SEWER, STORM SEWER, WATER, GAS, ELECTRICAL, TELEPHONE,
SEATING: NONE
A7
ROOF PLAN
ETC. ANY DISCREPANCIES IN UTILITY LOCATIONS SHALL BE BROUGHT TO THE
XX'--X-L- ELEVATION
A REVISION NUMBER
BUILDING CONSTRUCTION TYPE: V -B, (NON-SPRINKLERED)
IMMEDIATE ATTENTION OF THE OWNER'S REPRESENTATIVE.
XXX
--ELEVATION NOTE
10.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE BUILDING'S
OCCUPANCY GROUP: B
MECHANICAL
STRUCTURAL SYSTEM, STRUCTURAL MEMBERS, INCLUDING BEARING AND SHEARABBREVIATIONS
OCCUPANCY LOAD: GROSS SQ. FT. WHOLE SPACE = 1,566 SQ. Fr.
WALLS, SHALL NOT BE REMOVED, CUT OR OTHERWISE MODIFIED WITHOUT WRITTEN
"KITCHEN AREAS" = 1244 SF/200 SF (GROSS) = 6 OCCUPANTS
I
AUTHORIZATION FROM THE OWNER'S REPRESENTATIVE.
"CUSTOMER AREA" = 322 SF/100 SF (GROSS) = 3 OCCUPANTS
M1
H.V.A.C. FLOOR PLAN
11.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL BUILDING
A.B.
ANCHOR BOLT
F.P.
FIRE PROOF
REINF.
REINFORCING
DIMENSIONS AND SHALL IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE OF ANY
REQ'D.
REQUIRED
M2
H.V.A.C. SCHEDULES
VARIANCE OR DISCREPANCY AFFECTING NEW CONSTRUCTION.
A.T.
ACOUSTICAL TILE
FLASH
FLASHING
RET.
RETURN
TOTAL OCCUPANT LOAD = 9
12.
GENERAL CONTRACTOR SHALL COORDINATE EXISTING STRUCTURE WITH NEW
ADJ.
ADJUSTABLE
FLR.
FLOOR
R.A.
RETURN AIR
M3
H.V.A.C. DETAILS
CONSTRUCTION INCLUDING MECHANICAL, FIRE PROTECTION AND ELECTRICAL WORK.
F.D.
FLOOR DRAIN
EXITS REQUIRED = 1
M4
H.V.A.C. DETAILS
13,
CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING IN WALLS FOR SUPPORT OF
A.F.F.
ABOVE FINISH FLOOR
F.S.
FLOOR SINK
REV.
REVERSE
EXITS PROVIDED = 2
ALL EQUIPMENT, SHELVING, ACCESSORIES AND OTHER DEVICES REQUIRED.
A.C.
AIR CONDITIONING
FT.
FOOT
RCP
REFLECTED CEILING
M5
HNA.C. GENERAL NOTES
14.
ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS.
ANDD.
ANODIZED
FTG.
FOOTING
PLAN
M6
HOOD DRAWINGS
15.
VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY
ALUM/AL
ALUMINUM
FDN.
FOUNDATION
R. D.
ROOF DRAIN
M7
HOOD FAN DRAWINGS
TOILET FIXTURES: UNISEX HANDICAP ACCESSIBLE 1 W.C.
THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK.
APPROX.
APPROXIMATE
GA.
GAUGE
ROOF'G.
ROOFING
1 LAVATORY
M8
ANSUL DRAWINGS
16.
THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS
BD.
BOARD
RM.
ROOM
OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS.
BEAM
G.C.
GENERAL CONTRACTOR
ELECTRICAL
17. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNING
GEN. GENERAL
R.O. ROUGH OPENING
BILK.
BLOCK
EXISTING PARTITIONS, ETC., VERIFICATION MUST BE DONE IN THE FIELD.
G. 1. GALVANIZED IRON
S. E. SATIN ENAMEL
BLK'G. BLOCKING
PROJECT TEAM
18.
UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY
GL.
GLASS; GLAZING; GLAZED
SCHED.
SCHEDULE
E1
ELECTRICAL RISER DIAGRAMS &PANEL SCHEDULES
LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH
BOT.
BOTTOM
GR.
GRADE
INSPECTIONS AND CERTIFICATES OF OCCUPANCY,
BLDG
BUILDINGGYP.
GYPSUM
SECT.
SECTION
E2
ELECTRICAL POWER/ROOF PLAN
NOTE:
19.
THESE CONSTRUCTION NOTES AND DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN
B.N.
BOUNDARY NAIL
HDWD
HARDWOOD
S.G.E.
SEMI -GLOSS ENAMEL
CONTACT CHRIS TUCKER INFORMATION BELOW FOR ALL BID
( )
E3
ELECTRICAL LIGHTING PLAN
AND GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE
INQUIRIES ON THIS PROJECT.
FINEST QUALITY OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT.
CAB.
CABINET
HDWE
HARDWARE
SHT'G.
SHEATHING
E4
HOOD CONTROL DRAWINGS
20.
ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND
CLG.
CEILING
H.D.
HUB DRAIN
SHT.
SHEET
OWNER
ARCHITECT
ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND
CEM. CEMENT
HT. HEIGHT
S.C.R. SILICONE CONTROL
COORDINATED IN ADVANCE WITH THE OWNER AND FIRE DEPARTMENT.
RECTIFIER
PLUMBING
�^
C.F.
CURB FACE
H.M.
HOLLOW METAL
NPC INTERNATIONAL
MARC BRUNDIARCHITECT
21.
GENERAL CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS FOR PARTITION DETAILS
HORIZ.
HORIZONTAL
SIM.
SIMILAR
7300 W. 129TH. ST.
8951 CYPRESS WATERS BLVD., SUITE 130
ON SHEET A6 TO DETERMINE APPROPRIATE CONNECTIONS TO STRUCTURE ABOVE.
CENTERLINE
SK.
SINK
OVERLAND PARK, KANSAS 66213
DALLAS, TX 75019
P1
PLUMBING SCHEDULES
I/F
INTERFACE
22.
ALL CHANGE ORDER REQUESTS SHALL BE SUBMITTED IN WRITING TO NPC PROJECT
C.T.
CERAMIC TILEINS.
S.D.
SOAP DISPENSER
PHONE: (913) 327-5555
PHONE: 972.929.9226
WASTE AND VENT PLAN
MANAGER FOR APPROVAL PRIOR TO MAKING ANY CHANGES.
INSULATE; INSULATION
FAX: (913) 327-5850
FAX: 972.929.9061
P2
CLR.
CLEAR
INT.
INTERIOR
S.O.H.
SAME OPPOSITE HAND
P3
GAS AND WATER PLAN
23•
G.C./SUBCONTRACTORS ARE RESPONSIBLE FOR MECHANICAL, ELECTRICAL AND
COL.
COLUMN
JNT.
JOINT
SOL.
SOLID
PLUMBING PERMITS.
P4
PLUMBING DETAILS
NPC PROJECT MANAGER
MECHANICAL/ELECTRICAL ENGINEER
24. GENERAL CONTRACTOR IS RESPONSIBLE TO RECEIVE AND SECURELY STORE ALL
CONC. CONCRETE
JST. JOIST
SPECS. SPECIFICATIONS
OWNER SUPPLIED EQUIPMENT/ITEMS,
C.B.
CONCRETE BLOCK
LAM.
LAMINATE; LAMINATED
SQ.
SQUARE
ACERTUS GROUP
LTG.
LIGHTING
S.S. S/S STAINLESS STEEL
CHRIS TUCKER
14817 WEST 95TH STREET
SPECIFICATIONS
CONST.
CONSTRUCTION
MFR.
MANUFACTURER
S.S.D.
SEE STRUCTURAL DWGS
N. 4059 N 1400 E.
LENEXA, KS 66215
CONT.
CONTINUOUSBUHL,
MAT'L.
MATERIAL
STD.
STANDARD
ID 73316
PHONE: (208) 316-3789
PHONE: (913) 322-5150
SPECIFICATIONS PROVIDED ON A CD IN BOOK FORMAT.
C.J.
CONTRACTION OR
STL.
STEEL
EMAIL: CHRIS.TUCKER@NPCINTERNATIONAL.COM
FAX: (913) 322-5155
CONTROL JOINT
MAX.
MAXIMUM
CONTR.
CONTRACTOR
MECH.
MECHANICAL
STOR.
STORAGE
STRUCTURAL ENGINEER
--` --
MEMB.
MEMBRANE
ST.
STREET; STRAIN
-
--'-
CORR.
CORRIDOR
STRUCTURAL EDGE ENGINEERING
MET/MTL
METAL
STRUCT.
STRUCTURAL
5509 N. GLENWOOD STREET
CTRD.
CENTERED
BOISE, ID
DP.
DEEP
M.L.
METAL LATH
SUSP.
SUSPEND; SUSPENDED
8)6
PHONE: (2008)658-0218
5
DET.
DETAIL
MIN.
MINIMUM
SW.
SWITCH
EMAIL: DAVIDS@STRUCTURALEDGE.COM
CONTACT: DAVID SANSOTTA
DIAG.
DIAGONAL
MISC.
MISCELLANEOUS
SYS.
SYSTEM
DIA.
DIAMETER
MLDG.
MOULDING
TEL.
TELEPHONE
N.A.
THERMO.
THERMOSTAT
- -- ------
-----N/A
DIM,
DIMENSION
N/A
NOT APPLICABLE
THK.
THICK
SCOPE OF PROJECT
DR. DOOR
THRU. THROUGH
N.LC.
NOT IN CONTRACT
DBL.
DOUBLE
TOIL.
TOILET
ON.
DOWN
N.T.S.
NOT TO SCALE
THIS IS A TENANT LEASE AND IMPROVEMENT IN AN EXISTING BUILDING. OPERATION IS A PIZZA CARRY -OUT
N0.
NUMBER
T.C.
TOP OF CURB
RESTAURANT. PARKING, INCLUDING ACCESSIBLE SPACES, IS EXISTING AND IS THE RESPONSIBILITY OF THE LANDLORD.
D. S.
DIRECTIONAL SIGN
T. P.
TOP OF PAVING
0
OWNER
DT.
DRIVE-THRU
T. R.
TOP OF ROOF
OFF.
OFFICE
T
LOCATION MAP
DWG.
DRAWING
T. P.
TOP OF PARAPET
O.C.
ON CENTER
EA.
EACH
T.S.
TOP OF SLAB
E. S.
EACH SIDE
OFCI
OWNER FURNISHED
T.W.
TOP OF WALL
CONT'R INSTALLED
EJ,F.S.
EXTERIOR INSULATION &
T.S.B.
TOP SET BASE
FINISH SYSTEM
OPN'G.
OPENING
T,
TREAD
ELEC.
ELECTRICAL
OPP.
OPPOSITE
PROPOSED PIZZA HUT
T.S.
TUBULAR STEEL
E. P.
ELECTRICAL PANEL
O.A.
OVERALL
TYP•
TYPICAL
EL.
ELEVATION (GRADE)
O.A.H.
OVERALL HEIGHT
U. L.
UNDERWRITING
ELEV.
ELEVATION (BLDG)
LABORATORIES
E. N.
EDGE NAIL
O.H.
OVERHEAD
ENCL.
ENCLOSURE
P.C.
POST CAP
UNFIN.
UNFINISHED
E.M.S.
ENERGY MANAGEMENT
P.C.C.
PORTLAND CEMENT
U.O.N.
UNLESS OTHERWISE
T
,•,;,, „•. ,;..... .,..
SYSTEM
CONCRETE
NOTED
E.P.C.
ECCENTRIC POST CAP
P.G.
PAINT GRADE
VENT.
VENTILATE; VENTILATION
EQ.
EQUAL
P.H.
PIZZA HUT
VEST.
VESTIBULE
EQUIP.
EQUIPMENT
PR.
PAIR
V.W.C.
VINYL WALL COVERING
EXH.
EXHAUST
PNL
PANEL
W.C.
WATERCLOSET
EXIST.
EXISTING
PART.
PARTITION
W.P.
WATERPROOF
E.J.
EXPANSION JOINT
PERF.
PERFORATION
EXP.
EXPOSED; EXPANSION
PLAS.
PLASTER
W.W.F.
WELDED WIRE FABRIC
EXT,
EXTERIOR
PTDF
PRESSURE TREATED
W.
WIDE; WIDTH
FIN.
FINISH
DOUGLAS FIR
W/
WITH
F.R.P.
FIBERGLASS REINFORCED
PLYWD.
PLYWOOD
PANEL
PROP.
PROPERTY
W/0
WITHOUT
F. F.
FINISH FLOOR
P. L.
PROPERTY LINE
WD.
WOOD
F. E.
FIRE EXTINGUISHER
P.V.C.
POLY VINYL CHLORIDE
W.I.C.
WALK-IN COOLER
F.E.C.
FIRE EXTINGUISHER
R.
RISER
CABINET
W.I.F.
WALK-IN FREEZER
REFR.
REFRIGERATOR .
R. S.
ROUGH SAWN
n �
X 2
rr 0
yj ZLa
3 V
D O' O V
Z X
Q LJ
F— 0
Lli Z
Ld
_ (�
N Z_
W
IG
FRANCHISEE
OMAN-
mM"
international
7300 W. 129TH STREET
OVERLAND PARK, KANSAS
66213
PHONE: (913) 327-5555
FAX: (913) 327-5850
MMOMIN
LJ
F—
V)
I— N 2
Q
= a
m
N m
N M m
(D LAj
ol
U
i
i o
QN
v
Y
11A -o
� m
N
4! N
R O1
c O N 001
Ln 01
OJ^ fVN
s V a L— cn,4
a' v y r,
CC Ln - O X
v` G 0O100CL
LICENSED
ARCHITECT
AR -984297
v�
N
N
Pa1.ARC W. BRUNDISE
ST.�TE OF IDAHO
SHEET NUMBER
z T1
W
a'