HomeMy WebLinkAboutTRUSS LOAD CALCULATIONS - 19-00401 - Pizza Hut - Tenant Remodel_$_i tructurall F-1 por! pog riq `-a`JU.J`a E N G I N E E R I N G 6/23/2019 Brett Labrie Lindgren-Labrie Architecture 247 N. Eagle Rd. Eagle, Idaho 83616 RE: Rexburg In -Line Rexburg, ID RTU Addition Brett, Per our discussion regarding the above-mentioned project, the currently designed roof trusses and framing have a 7501b add -load designed into each individual truss to allow for RTU placements within the mechanical zones indicated on the S2 sheet. This information is noted in Keynote #7 on the S2 sheet. Per this note, each roof truss can support up to 7501b at any point in addition to the typical roof dead and snow loads. For example, a 15001b unit can be supported equally by two adjacent joists in the mechanical zone and be structurally acceptable as each truss will support 7501b each. If you have any questions, please don't hesitate to contact our office. Sincerely, David Sansotta, P.E. E 14438 W R b OF ID ��1t?LAS 5a 06/26/2019 5509 N. Glenwood St. Boise, ID 83714 1 o: 208.501.2289 1 www.structuraledge.com