HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00119 - 2312 W 960 S - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 07/02/2019 1:19 pm
Permit Details Permit Number: 14-00119
2312 W 960 S - SFR
2312 W 960 S
Building - Single Family Residence
Permit Issued Date: 04/03/2014
Permit Inspection Statistics
21Total Inspections Completed:
18Total Inspections Passed:
Inspection Pass Rate: 85.71%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/08/2014PassTed DyeFoundation Inspection
04/08/2014PassTed DyeFooting Inspection
05/13/2014PassTed DyeSheeting
05/21/2014FailTed DyeFraming/Structure Inspection
TJI cut above west tub.
can for see a problem insulating behind entertainment center.
fire blocking needed at fur downs.
Inspector Comments:
05/23/2014PassQuinton OwensFraming/Structure Inspection
Joist added next to cut joist. Solution to insulating behind Ent. Ctr. being worked
on and Insulation to be used as fire block at dropped ceiling.
Inspector Comments:
05/28/2014PassTed DyeInsulation Inspection
06/10/2014PassTed DyeSheetrock/Drywall Inspection
07/16/2014PassTed DyeSidewalk Inspection
07/16/2014FailTed DyeBuilding Final
There needs to be a 3 foot landing at the back door.
There needs to be a gasket or weather stripping around the access hole.
The mechanical trim has not been completed.
Inspector Comments:
07/17/2014PassTed DyeBuilding Final
Electrical Inspection Type
04/17/2014PassPLL ADMINResidential Electrical Service Inspection
Pass
As per Jane Shaw.
Inspector Comments:
05/21/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
07/09/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Page 1 of 2
(Continued)
Permit Details Permit Number: 14-00119
2312 W 960 S - SFR
2312 W 960 S
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 07/02/2019 1:19 pm
Permit
Inspection
Summary
Mechanical Inspection Type
05/21/2014PassDon AllenHVAC Rough-in
All good th cover the rough
Gas presser held at 80 lb
Inspector Comments:
07/17/2014PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments:
Plumbing Inspection Type
04/15/2014PassDon AllenPlumbing Sewer
All good to cover the sewer and waterInspector Comments:
04/15/2014PassDon AllenPlumbing Water
All good to cover the water lineInspector Comments:
04/18/2014PassDon AllenPlumbing Underground Inspection
All good to cover the ground workInspector Comments:
05/16/2014PassDon AllenPlumbing Rough-in
good to cover the plumbing rough inInspector Comments:
07/15/2014PassDon AllenPlumbing Final Inspection
07/15/2014FailDon AllenPlumbing Final Inspection
Need to install tempering valve for the tub in master according to code 414.5 in
the Idaho plumbing code.
Inspector Comments: