HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00123 - 588 Terra Vista Dr - SFR & Basement FinishPermit Inspection Summary Permit Status of (Open) as of Report Date: 07/02/2019 11:40 am Permit Details Permit Number: 14-00123 588 Terra Vista Dr - SFR & Basement Finish 588 Terra Vist Dr Building - Single Family Residence Permit Issued Date: 04/11/2014 Permit Inspection Statistics 25Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 76.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/14/2014FailTed DyeFooting Inspection The footing does not have a enough depth. Excavate footing of raise grade to have a min. of 8". Call when completed for a reinspect. Inspector Comments: 04/14/2014PassTed DyeFooting Inspection corrections made to F1 footingsInspector Comments: 04/22/2014PassTed DyeFoundation Inspection 04/24/2014N/ATed DyeRadon-Ground Inspection 06/02/2014PassTed DyeSheeting 06/12/2014PassTed DyeFraming/Structure Inspection 06/17/2014PassTed DyeInsulation Inspection Blown in walls and floors on main floor. Batts on exterior basement walls. Batts in the garage. Inspector Comments: 06/23/2014PassTed DyeSheetrock/Drywall Inspection Main and basement drywalled. Screw Pattern look good. They have started taping. Inspector Comments: 08/08/2014PassTed DyeSidewalk Inspection 12+ inches of granular fillInspector Comments: 08/20/2014FailTed DyeResidential Building Final 08/22/2014FailTed DyeResidential Building Final smoke detector missing at bottom of stairsInspector Comments: 08/25/2014PassTed DyeCommercial Building Final 08/28/2014PassTed DyeCommercial Building Final The grading has been completed around the house. OK to issue the C. O. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 14-00123 588 Terra Vista Dr - SFR & Basement Finish 588 Terra Vist Dr Building - Single Family Residence Permit Status of (Open) as of Report Date: 07/02/2019 11:40 am Permit Inspection Summary Electrical Inspection Type 06/12/2014PassBret StoddardCommercial Electrical Rough-in Wall okay for cover, per Gabe Madrid.Inspector Comments: 07/11/2014PassBret StoddardResidential Electrical Service Inspection Rocky Mountain Power Work Request #5925425Inspector Comments: 08/19/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 08/20/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Living room basement closet light removed for lack of clearance. No A/C unit installed (30A OCPD). Inspector Comments: Mechanical Inspection Type 06/12/2014PassDon AllenHVAC Rough-in All good to cover the rough inInspector Comments: 08/20/2014PassDon AllenHVAC Final Inspection All good for c/oInspector Comments: Plumbing Inspection Type 04/29/2014PassDon AllenPlumbing Underground Inspection 05/02/2014PassDon AllenPlumbing Sewer good to cover the sewerInspector Comments: 05/02/2014PassDon AllenPlumbing Water good to cover Chris Scott at the water department looked at itInspector Comments: 06/12/2014PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 08/20/2014FailDon AllenPlumbing Final Inspection 08/22/2014PassDon AllenPlumbing Final Inspection All good for c/oInspector Comments: Page 2 of 2