HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00106 - 935 S 2380 W - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 07/02/2019 9:57 am Permit Details Permit Number: 14-00106 935 S 2380 W - SFR 935 S 2380 W Building - Single Family Residence Permit Issued Date: 03/25/2014 Permit Inspection Statistics 24Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 79.17% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 03/25/2014PassTed DyeFooting Inspection 03/27/2014PassTed DyeFoundation Inspection rebar tied,spacing good and spaced properlyInspector Comments: 04/28/2014PassTed DyeSheeting Sheeting approved for coverInspector Comments: 05/05/2014FailTed DyeFraming/Structure Inspection -the electrical has nor been done. -strap outside walls to inside wall where they come to a "T". -add a king stud along side beam for covered porch (just south of south garage door). -i will re-inspect home at the completion of electrical rough-in. Inspector Comments: 05/07/2014FailTed DyeFraming/Structure Inspection fire blocking needed at fur downs. can check when insulation inspection is done.Inspector Comments: 05/12/2014PassTed DyeInsulation Inspection Insulation looks good. ApprovedInspector Comments: 05/16/2014PassTed DyeSheetrock/Drywall Inspection 05/22/2014PassTed DyeSidewalk Inspection base has 6+ of road basementInspector Comments: 06/10/2014PassTed DyeFraming/Structure Inspection 06/17/2014PassTed DyeSidewalk Inspection 06/17/2014FailTed DyeBuilding Final 1 clearance needed around B vent. Weather stripping missing on front and garage doors. The Smoke detector in Southeast bedroom is not communicating with others. Inspector Comments: 06/19/2014PassTed DyeBuilding Final Page 1 of 2 (Continued) Permit Details Permit Number: 14-00106 935 S 2380 W - SFR 935 S 2380 W Building - Single Family Residence Permit Status of (Open) as of Report Date: 07/02/2019 9:57 am Permit Inspection Summary Electrical Inspection Type 04/03/2014PassBret StoddardResidential Electrical Service Inspection 05/06/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 06/11/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Missing receptacle in bedroom to the immediate right of stair landing (upstairs front of house) on wall by return air. Probably covered with drywall., Locate box and trim out, per Gabe Madrid. Inspector Comments: 06/13/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 05/05/2014PassDon AllenHVAC Rough-in gas presser held at 75lbInspector Comments: 06/17/2014PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: Plumbing Inspection Type 04/01/2014PassDon AllenPlumbing Water all good to cover waterInspector Comments: 04/01/2014FailDon AllenPlumbing Sewer all good to cover sewer lineInspector Comments: 04/01/2014PassDon AllenPlumbing Sewer 04/14/2014PassDon AllenPlumbing Underground Inspection All good to cover the ground workInspector Comments: 04/30/2014PassDon AllenPlumbing Rough-in 06/17/2014PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Page 2 of 2