Permit Status of (Open) as of Report Date: 07/02/2019 9:57 am
Permit Details Permit Number: 14-00106
935 S 2380 W - SFR
935 S 2380 W
Building - Single Family Residence
Permit Issued Date: 03/25/2014
Permit Inspection Statistics
24Total Inspections Completed:
19Total Inspections Passed:
Inspection Pass Rate: 79.17%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
03/25/2014PassTed DyeFooting Inspection
03/27/2014PassTed DyeFoundation Inspection
rebar tied,spacing good and spaced properlyInspector Comments:
04/28/2014PassTed DyeSheeting
Sheeting approved for coverInspector Comments:
05/05/2014FailTed DyeFraming/Structure Inspection
-the electrical has nor been done.
-strap outside walls to inside wall where they come to a "T".
-add a king stud along side beam for covered porch (just south of south garage
door).
-i will re-inspect home at the completion of electrical rough-in.
Inspector Comments:
05/07/2014FailTed DyeFraming/Structure Inspection
fire blocking needed at fur downs. can check when insulation inspection is done.Inspector Comments:
05/12/2014PassTed DyeInsulation Inspection
Insulation looks good. ApprovedInspector Comments:
05/16/2014PassTed DyeSheetrock/Drywall Inspection
05/22/2014PassTed DyeSidewalk Inspection
base has 6+ of road basementInspector Comments:
06/10/2014PassTed DyeFraming/Structure Inspection
06/17/2014PassTed DyeSidewalk Inspection
06/17/2014FailTed DyeBuilding Final
1 clearance needed around B vent.
Weather stripping missing on front and garage doors.
The Smoke detector in Southeast bedroom is not communicating with others.
Inspector Comments:
06/19/2014PassTed DyeBuilding Final
Page 1 of 2
(Continued)
Permit Details Permit Number: 14-00106
935 S 2380 W - SFR
935 S 2380 W
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 07/02/2019 9:57 am
Permit
Inspection
Summary
Electrical Inspection Type
04/03/2014PassBret StoddardResidential Electrical Service Inspection
05/06/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
06/11/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Missing receptacle in bedroom to the immediate right of stair landing (upstairs
front of house) on wall by return air. Probably covered with drywall., Locate box
and trim out, per Gabe Madrid.
Inspector Comments:
06/13/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Mechanical Inspection Type
05/05/2014PassDon AllenHVAC Rough-in
gas presser held at 75lbInspector Comments:
06/17/2014PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments:
Plumbing Inspection Type
04/01/2014PassDon AllenPlumbing Water
all good to cover waterInspector Comments:
04/01/2014FailDon AllenPlumbing Sewer
all good to cover sewer lineInspector Comments:
04/01/2014PassDon AllenPlumbing Sewer
04/14/2014PassDon AllenPlumbing Underground Inspection
All good to cover the ground workInspector Comments:
04/30/2014PassDon AllenPlumbing Rough-in
06/17/2014PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments: