HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00090 - 661 Tanglewood Dr - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 07/01/2019 12:11 pm
Permit Details Permit Number: 14-00090
661 Tanglewood Dr - SFR
661 Tanglewood Dr
Building - Single Family Residence
Permit Issued Date: 04/10/2014
Permit Inspection Statistics
25Total Inspections Completed:
18Total Inspections Passed:
Inspection Pass Rate: 72.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/21/2014PassTed DyeFooting Inspection
Rebar tied and lifted of the groundInspector Comments:
04/23/2014PassTed DyeFoundation Inspection
-ufer ground with power conduits.
-all overlaps looked good.
-2 rebar in top 12" of concrete.
-rebar away from forms at lest 2"
Inspector Comments:
06/04/2014FailTed DyeSheeting
Windows in SE and NW bedrooms have areas that have been missed stapling on
edge bands. their is one location between those same bedrooms that was missed
being stapled.
On the S.W. end of house there is one edge band that has been missed.
One location in garage also.
Framer marked all locations mentioned above and will staple.
No hold down straps have been nailed down, those also were discussed.
Inspector Comments:
06/18/2014PassTed DyeSheeting
07/08/2014FailTed DyeFraming/Structure Inspection
-Anchor bolts are needed on bearing walls in basement. Spacing. ...6'on center
maximum.
-Blocking needed in floor TJI system where exterior wall (end wall) bears on only
one rim joist.
Blocking to be every 4'and perpendicular.
Inspector Comments:
07/14/2014FailTed DyeFraming/Structure Inspection
Anchor bolts are needed on bearing walls in basement. Spacing. ...6'on center
minimum.
Inspector Comments:
07/16/2014PassTed DyeFraming/Structure Inspection
07/16/2014PassTed DyeInsulation Inspection
07/23/2014FailTed DyeCommercial Sheetrock/Drywall Inspection
07/28/2014FailTed DyeResidential Sheetrock/Drywall Inspection
one truss above stairs missed being screwed offInspector Comments:
07/29/2014PassTed DyeResidential Sheetrock/Drywall Inspection
Page 1 of 2
(Continued)
Permit Details Permit Number: 14-00090
661 Tanglewood Dr - SFR
661 Tanglewood Dr
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 07/01/2019 12:11 pm
Permit
Inspection
Summary
09/24/2014PassTed DyeSidewalk Inspection
Subtract has 6 " plus granular fillInspector Comments:
11/24/2014FailTed DyeResidential Building Final
12/04/2014PassTed DyeResidential Building Final
Ok to issue C.O.Inspector Comments:
06/18/2015PassTed DyeResidential Building Final
Electrical Inspection Type
07/10/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
11/24/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Mechanical Inspection Type
07/09/2014FailDon AllenHVAC Rough-in
need to install the duct work on the exhaust fan in the kitchen.
No gas line was ran
Inspector Comments:
07/14/2014PassDon AllenHVAC Rough-in
All good on the rough in.Gas presser held at 60 lbInspector Comments:
11/24/2014PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments:
Plumbing Inspection Type
05/02/2014PassDon AllenPlumbing Underground Inspection
good to cover ground workInspector Comments:
05/15/2014PassDon AllenPlumbing Sewer
good to cover the sewerInspector Comments:
05/19/2014PassDon AllenPlumbing Water
Chuck Velmen at the water department looked at the water line and ok the line.Inspector Comments:
07/01/2014PassDon AllenPlumbing Rough-in
Good to cover the plumbing rough inInspector Comments:
11/24/2014PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
Page 2 of 2