HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00126 - 148 Harvard Ave - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 07/01/2019 10:19 am
Permit Details Permit Number: 14-00126
148 Harvard Ave - SFR
148 Harvard Ave
Building - Single Family Residence
Permit Issued Date: 04/18/2014
Permit Inspection Statistics
25Total Inspections Completed:
19Total Inspections Passed:
Inspection Pass Rate: 76.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/18/2014PassTed DyeFooting Inspection
04/18/2014PassTed DyeFooting Inspection
04/21/2014PassTed DyeFoundation Inspection
06/19/2014FailTed DyeSheeting
Some sheeting missed being nailed to the studs. The Studs are marked with
green and black paint.
We can inspect the corrections at the time of the framing inspection or call for a
reinspect.
Inspector Comments:
06/27/2014FailTed DyeFraming/Structure Inspection
Put truss tie downs on back porch trusses.
top of stairs going to bonus is not finished
Can check these items at insulation inspection
Inspector Comments:
07/01/2014FailQuinton OwensFraming/Structure Inspection
Top winder treads incorrect - narrowest end of treads must be 6" min. Add studs
for drywall backing at top of stairs. More support needed for ceiling drywall at
basement drops (drywall span limited to 2 ft). Lateral bracing missing above
bearing wall. Anchor bolts needed in bearing wall. Ceiling in basement apt not
rated at exhaust fan penetrations, and will need to be rated in concealed space
above fireplace.
Inspector Comments:
07/01/2014FailQuinton OwensInsulation Inspection
Windows not installed. Did not seal door bell wire penetration at top plate in hall.Inspector Comments:
07/09/2014PassTed DyeSheetrock/Drywall Inspection
09/18/2014PassTed DyeResidential Building Final
Approved for finalInspector Comments:
10/27/2014PassTed DyeSheeting
10/29/2014PassTed DyeCommercial Insulation Inspection
10/29/2014PassQuinton OwensResidential Framing/Structure Inspection
10/29/2014PassTed DyeSidewalk Inspection
10/29/2014PassTed DyeCommercial Building Final
Page 1 of 2
(Continued)
Permit Details Permit Number: 14-00126
148 Harvard Ave - SFR
148 Harvard Ave
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 07/01/2019 10:19 am
Permit
Inspection
Summary
Electrical Inspection Type
06/30/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
07/07/2014PassBret StoddardResidential Electrical Service Inspection
09/12/2014PassSAUREY AMANDASFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
GFCI Cover in mech room
Faceplates in master bathroom (installed backsplash) Main panel cover installed
Contractor on site made corrections.
Inspected and approved per Jane Allred.
Inspector Comments:
Mechanical Inspection Type
06/27/2014PassDon AllenHVAC Rough-in
All good to coverInspector Comments:
09/12/2014PassDon AllenHVAC Final Inspection
hvac looks good all good for the c/oInspector Comments:
Plumbing Inspection Type
04/30/2014FailDon AllenPlumbing Underground Inspection
need to install the tracer lineInspector Comments:
06/30/2014PassDon AllenPlumbing Underground Inspection
Good to cover the under groundInspector Comments:
06/30/2014PassDon AllenPlumbing Rough-in
All good to cover the rough inInspector Comments:
08/20/2014PassDon AllenPlumbing Sewer
09/12/2014FailDon AllenPlumbing Final Inspection
10/29/2014PassDon AllenPlumbing Final Inspection
Page 2 of 2