Permit Status of (Open) as of Report Date: 06/27/2019 11:21 am
Permit Details Permit Number: 14-00199
918 S 2275 W - SFR
918 S 2275 W
Building - Single Family Residence
Permit Issued Date: 05/15/2014
Permit Inspection Statistics
21Total Inspections Completed:
19Total Inspections Passed:
Inspection Pass Rate: 90.48%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
05/20/2014PassTed DyeFooting Inspection
05/21/2014PassTed DyeFooting Inspection
Stopped and checked vertical rebar in footings and found that they had been
jabbed in instead of having a bend on them.
I called the contractor and the in turn called the concrete sub..
They came and removed the vertical rebar before the concrete had set up fully
and then the next morning they used epoxy to embed them in. holes 2/3 filled
before rebar was pounded back in.
Inspector Comments:
05/22/2014PassTed DyeFoundation Inspection
rebar looked good. All overlaps good, rebar has proper spacing.Inspector Comments:
06/17/2014PassTed DyeSheeting
06/27/2014PassTed DyeFraming/Structure Inspection
07/03/2014PassQuinton OwensInsulation Inspection
Insulation approved for cover (blown fiberglass in walls, windows and doors
sealed, attic rulers installed). Netting will be needed at edge of vaulted ceiling to
keep required thickness of insulation above ceiling.
Inspector Comments:
07/08/2014PassTed DyeSheetrock/Drywall Inspection
-Drywall inspection passed.
O K to tape and texture.
Inspector Comments:
08/11/2014PassTed DyeSidewalk Inspection
08/11/2014FailTed DyeResidential Building Final
The lid in the access hole in garage needs to be type X 5/8 firecode sheetrock.
smoke detector in master bedroom is not communicating with other smoke
detectors.
the faucet over the tub will not shut off totally
the faucet over the tub will not shut off totally
Inspector Comments:
08/13/2014PassTed DyeResidential Building Final
Page 1 of 2
(Continued)
Permit Details Permit Number: 14-00199
918 S 2275 W - SFR
918 S 2275 W
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 06/27/2019 11:21 am
Permit
Inspection
Summary
Electrical Inspection Type
06/02/2014PassBret StoddardResidential Electrical Service Inspection
06/27/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
08/05/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Mechanical Inspection Type
06/27/2014PassDon AllenHVAC Rough-in
All good to cover the hvac rough in
Gas presser held above 60 lb
Inspector Comments:
08/11/2014FailDon AllenHVAC Final Inspection
Need to finish trimming out the exhaust fan in the kitchenInspector Comments:
08/13/2014PassDon AllenHVAC Final Inspection
All good for c/oInspector Comments:
Plumbing Inspection Type
All good to cover the water line
will check grade of meter at final
Inspector Comments:
05/28/2014PassDon AllenPlumbing Water
All good to cover the water line
will check grade of meter at final
Inspector Comments:
05/28/2014PassDon AllenPlumbing Sewer
All good to cover the sewerInspector Comments:
06/02/2014PassDon AllenPlumbing Underground Inspection
All good to cover the under groundInspector Comments:
06/20/2014PassDon AllenPlumbing Rough-in
all good to cover the plumbing rough inInspector Comments:
08/11/2014PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments: