Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00198 - 880 S 2275 WPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/27/2019 11:13 am Permit Details Permit Number: 14-00198 880 S 2275 W - SFR 880 S 2275 W Building - Single Family Residence Permit Issued Date: 05/19/2014 Permit Inspection Statistics 21Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 90.48% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/20/2014PassTed DyeFooting Inspection 05/21/2014PassTed DyeFooting Inspection Stopped and checked vertical rebar in footings and found that they had been jabbed in instead of having a bend on them. I called the contractor and the in turn called the concrete sub.. They came and removed the vertical rebar before the concrete had set up fully and then the next morning they used epoxy to embed them in. holes 2/3 filled before rebar was pounded back in. Inspector Comments: 05/21/2014PassTed DyeFoundation Inspection All over laps good. Rebar at proper heightsInspector Comments: 06/16/2014PassTed DyeSheeting 06/24/2014PassTed DyeFraming/Structure Inspection Insulate wires going through top plate above electrical panelInspector Comments: 06/30/2014PassQuinton OwensInsulation Inspection Insulation approved for cover. Need netting above edge of vaulted ceiling to maintain thickness of insulation above ceiling. Inspector Comments: 07/07/2014PassTed DyeSheetrock/Drywall Inspection 07/16/2014PassTed DyeSidewalk Inspection The sidewalk sub base on this home is complete has about 6 inches of Fill below the concrete sidewalk. Inspector Comments: 08/11/2014FailTed DyeCommercial Building Final lid in access hole in garage should be 5/8 type X fire code sheet rockInspector Comments: 08/13/2014PassTed DyeCommercial Building Final Electrical Inspection Type 06/02/2014PassBret StoddardResidential Electrical Service Inspection 06/24/2014PassBret StoddardCommercial Electrical Rough-in 08/06/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-No A/C unit is installed(30A OCPD).Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 14-00198 880 S 2275 W - SFR 880 S 2275 W Building - Single Family Residence Permit Status of (Open) as of Report Date: 06/27/2019 11:13 am Permit Inspection Summary Mechanical Inspection Type 06/27/2014PassDon AllenHVAC Rough-in All good to cover the rough in Gas presser held at 60 lb Inspector Comments: 08/11/2014FailDon AllenHVAC Final Inspection Need to finish trimming the exhaust fan in the kitchenInspector Comments: 08/13/2014PassDon AllenHVAC Final Inspection All good for c/oInspector Comments: Plumbing Inspection Type 05/27/2014PassDon AllenPlumbing Sewer All good to cover the sewer lineInspector Comments: 05/27/2014PassDon AllenPlumbing Water All good to cover the water lineInspector Comments: 06/02/2014PassDon AllenPlumbing Underground Inspection 06/20/2014PassDon AllenPlumbing Rough-in All good to cover the plumbing rough inInspector Comments: 08/11/2014PassDon AllenPlumbing Final Inspection all good fro the c/oInspector Comments: Page 2 of 2