Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00180 - 582 E 4th S - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/27/2019 10:21 am Permit Details Permit Number: 14-00180 582 E 4th S - SFR 582 E 4th S Building - Single Family Residence Permit Issued Date: 05/05/2014 Permit Inspection Statistics 23Total Inspections Completed: 20Total Inspections Passed: Inspection Pass Rate: 86.96% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/20/2014PassTed DyeFooting Inspection 05/27/2014PassQuinton OwensFoundation Inspection 06/26/2014PassTed DyeSheeting Nail patterns are good.4-6"on edges and 8-10" in the field. Approved for cover. Inspector Comments: 07/09/2014FailTed DyeFraming/Structure Inspection Anchor bolts are needed on bearing walls. Tighten the anchor bolts on exterior foundation walls. Inspector Comments: 07/11/2014PassTed DyeFraming/Structure Inspection 07/14/2014PassTed DyeInsulation Inspection 6" of cellulose in exterior walls. Batts an plastic in basement. Inspector Comments: 07/21/2014PassTed DyeResidential Sheetrock/Drywall Inspection -Partial basement finish (all but the two north west bedrooms and the mechanical room). Inspector Comments: 08/07/2014PassTed DyeSidewalk Inspection 12" plus of granular fill.Inspector Comments: 09/26/2014PassQuinton OwensSidewalk Inspection sidewalk completed. keep clean from dirt washing off finish grade.Inspector Comments: 09/26/2014FailQuinton OwensResidential Building Final Tempered window on wrong side of sliding door. No Smoke detector on ceiling near bottom of stairs as per NFPA 72, section 29.8.3.4(9) (CO det. will be required with future bedroom). Complete mechanical final inspection. Inspector Comments: Deficiency from the last inspections have been corrected.Inspector Comments: 10/01/2014PassTed DyeCommercial Building Final The C.O. will be issued upon the passing of the mechanical final.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 14-00180 582 E 4th S - SFR 582 E 4th S Building - Single Family Residence Permit Status of (Open) as of Report Date: 06/27/2019 10:21 am Permit Inspection Summary Electrical Inspection Type 07/09/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 07/11/2014PassBret StoddardResidential Electrical Service Inspection 09/26/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 07/09/2014PassDon AllenHVAC Rough-in Gas presser held at 75 lb Hvac looked good 2 bed rooms in the basement had no boots in the ceiling for supply air. Inspector Comments: 07/11/2014PassDon AllenHVAC Rough-in All good on the fire place downstairsInspector Comments: 09/26/2014FailDon AllenHVAC Final Inspection exhaust fan in bathroom basement needs to be finished. Exhaust fan for master bath needs exterior vent put on. Inspector Comments: 10/02/2014PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: Plumbing Inspection Type 05/30/2014PassDon AllenPlumbing Underground Inspection Good to cover the under groundInspector Comments: 06/03/2014PassDon AllenPlumbing Water All good to cover the water line Will look at final grade for the meter at final Inspector Comments: 06/03/2014PassDon AllenPlumbing Sewer All good to cover the sewer lineInspector Comments: 07/09/2014PassDon AllenPlumbing Rough-in 09/26/2014PassDon AllenPlumbing Final Inspection all good for c\oInspector Comments: Page 2 of 2