HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00171 - 311 Jefferson Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/27/2019 10:03 am Permit Details Permit Number: 14-00171 311 Jefferson Dr - SFR 311 Jefferson Dr Building - Single Family Residence Permit Issued Date: 05/15/2014 Permit Inspection Statistics 21Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 80.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/15/2014PassTed DyeFooting Inspection 2- 1/2" rebar suspended above ground base good set backs good. Inspector Comments: 05/15/2014PassTed DyeFoundation Inspection Everything looked good. 2-bars in top 12" overlaps look good bars away from forms Inspector Comments: 06/19/2014FailTed DyeSheeting Some sheeting missed being stapled to studs. They are marked with green paint on the inside of the stud. Complete corrections and we can inspect them at the time of the framing inspection. Inspector Comments: 07/07/2014PassTed DyeFraming/Structure Inspection At the bottom of the stairs, too the right in the closets, the top cord of the TJI has been cut about half way and to the right of that the Web has been to large. See attachments Inspector Comments: 07/09/2014PassTed DyeInsulation Inspection 6" exterior walls filled with cellulose insulation.Inspector Comments: 07/09/2014PassTed DyeSheeting Sheeting reinspect was done@ the framing inspection.Inspector Comments: 07/14/2014PassTed DyeSheetrock/Drywall Inspection 09/03/2014PassTed DyeSidewalk Inspection Sidewalk base has 6 " of compacted granular fill.Inspector Comments: 10/03/2014PassTed DyeResidential Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 14-00171 311 Jefferson Dr - SFR 311 Jefferson Dr Building - Single Family Residence Permit Status of (Open) as of Report Date: 06/27/2019 10:03 am Permit Inspection Summary Electrical Inspection Type 05/28/2014PassBret StoddardResidential Electrical Service Inspection 07/08/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 10/01/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 10/06/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection All deficiences are corrected. No A/C unit installed (50A OCPD).Inspector Comments: Mechanical Inspection Type 09/17/2014PassDon AllenHVAC Rough-in 10/06/2014PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: Plumbing Inspection Type 05/20/2014FailDon AllenPlumbing Underground Inspection need to install tracer line next to the water lineInspector Comments: 07/01/2014PassDon AllenPlumbing Rough-in All good to cover the plumbing rough inInspector Comments: 07/14/2014PassDon AllenPlumbing Underground Inspection All good to cover the under groundInspector Comments: 09/17/2014PassDon AllenPlumbing Rough-in 10/02/2014FailDon AllenPlumbing Final Inspection need to strap the water heaterInspector Comments: 10/06/2014PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Page 2 of 2