Permit Status of (Open) as of Report Date: 06/27/2019 9:53 am
Permit Details Permit Number: 14-00170
295 Jefferson Dr - SFR
295 Jefferson Dr
Building - Single Family Residence
Permit Issued Date: 05/13/2014
Permit Inspection Statistics
23Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 73.91%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
05/15/2014PassTed DyeFooting Inspection
2 -1/2" rebar suspended of the ground.
good base
setbacks right
Inspector Comments:
05/15/2014PassTed DyeFoundation Inspection
2 bars in to 12"
overlaps good
bars away from sides of forms
Inspector Comments:
07/11/2014FailTed DyeFraming/Structure Inspection
-Stairs are not to code. winder stairs can not jog in 6" and then start the 6" as
stated in the code. the 6" must start at the inside wall and then go in 12" and at
that point their has to be a measurement of 10" from the front of one tread to
the back of that same tread.
-Anchor bolts needed 6" from the ends of walls at all corners and from edges of
doors. The walls near the front entry have no anchor bolts in them at all. Check
all exterior walls.
-Interior bearing wall also need anchor bolts.
-Tempered glass needed in window at the bottom of the stairs
Inspector Comments:
07/14/2014FailTed DyeFraming/Structure Inspection
Repair of stairs is not completedInspector Comments:
07/15/2014PassTed DyeFraming/Structure Inspection
07/15/2014PassTed DyeInsulation Inspection
09/03/2014PassTed DyeSidewalk Inspection
Sidewalk base has 6" of compacted granular fill.Inspector Comments:
11/14/2014FailTed DyeResidential Building Final
11/14/2014PassTed DyeResidential Sheetrock/Drywall Inspection
drywall inspected at an earler date but missed being enteredInspector Comments:
11/14/2014PassTed DyeResidential Building Final
Page 1 of 2
(Continued)
Permit Details Permit Number: 14-00170
295 Jefferson Dr - SFR
295 Jefferson Dr
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 06/27/2019 9:53 am
Permit
Inspection
Summary
Electrical Inspection Type
05/28/2014PassBret StoddardResidential Electrical Service Inspection
07/14/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
10/03/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
10/06/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
All deficiencies corrected from prior inspection. No A/C unit installed (50A OCPD).Inspector Comments:
Mechanical Inspection Type
07/14/2014FailDon AllenHVAC Rough-in
The gas manifold needs to be brought out of the wall.The 1st port is in side the
wall and will be covered when sheet rocked.
Inspector Comments:
07/17/2014PassDon AllenHVAC Rough-in
hvac all good to coverInspector Comments:
11/14/2014PassDon AllenHVAC Final Inspection
hvac all good for the c/oInspector Comments:
Plumbing Inspection Type
06/02/2014PassDon AllenPlumbing Underground Inspection
09/22/2014FailDon AllenWater Meter Inspection
Need to install braceing for the meterInspector Comments:
10/05/2014PassDon AllenPlumbing Rough-in
10/29/2014PassDon AllenWater Meter Inspection
Water meter looks goodInspector Comments:
need to fix the hose bib on the back of the houseInspector Comments:
11/14/2014PassDon AllenPlumbing Final Inspection
Good for the c/oInspector Comments:
11/14/2014PassDon AllenPlumbing Final Inspection
OK to issue C.OInspector Comments: