HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00370 - 26 N Center St - Madison Fire Station - Addition & RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/26/2019 3:27 pm Permit Details Permit Number: 14-00370 26 N Center St - Madison Fire Station - Addition & Remodel 26 N Center St Commercial Addition Permit Issued Date: 12/17/2014 Permit Inspection Statistics 44Total Inspections Completed: 25Total Inspections Passed: Inspection Pass Rate: 56.82% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 12/17/2014PassQuinton OwensCommercial Footing Inspection 12/19/2014PassQuinton OwensFoundation Inspection Interior foundation for new walls. Only about 6" tall.Inspector Comments: 03/20/2015PassQuinton OwensCommercial Framing/Structure Inspection Lower metal decking under raised 2nd level floor approved. Support framing not done yet. Inspector Comments: 04/23/2015FailQuinton OwensCommercial Framing/Structure Inspection 2nd floor roof sheathing (excluding taller roof). Missing nailing on square sheet in SW corner, and one row on north side, and just north of SE mech. curb. Spacing of nails in field are too far on east half. Inspector Comments: 04/27/2015FailQuinton OwensCommercial Framing/Structure Inspection Sheathing re-inspect for 2nd floor lower roof. Missed nailing done in SW corner and north side (west half). Nail spacing still to be corrected (started nailing during inspection). Inspector Comments: 04/28/2015PassQuinton OwensSheeting 2nd floor lower roof.Inspector Comments: 04/28/2015N/AQuinton OwensCommercial Framing/Structure Inspection Framing between double metal floor decks for 2nd floor. (covered before inspected) Inspector Comments: 05/19/2015FailQuinton OwensCommercial Framing/Structure Inspection Windows in sleeping rooms do not meet egress. 2x4 spans supporting ceiling to be double checked. Ducts block continuation of fire barrier in NE corner of kitchen. Ducts penetrating Fire barrier does not have fire dampers. Stairs to roof on north side not done yet. Fire rating will need to be maintained at larger PVC pipe at top plate of fire barrier. Thermal barrier for foam insulation in attic required per 2603.4.1.6. Fireblocking/caulking not completed yet. Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 14-00370 26 N Center St - Madison Fire Station - Addition & Remodel 26 N Center St Commercial Addition Permit Status of (Open) as of Report Date: 06/26/2019 3:27 pm Permit Inspection Summary 06/22/2015FailQuinton OwensCommercial Framing/Structure Inspection Thermal barrier at ceiling or directly on foam insulation (verify requirements with ESR report). Properly firecaulk PVC pipe penetrations in fire barrier. Large vertical PVC pipe section in wall membrane also to be fire rated. Complete duct over NW sleeping room to be all 26 ga metal duct Complete fire barrier around metal duct on north end. Top stair riser going to lower roof is too high compared to other risers (accessory for R2 - will allow for residential stair limits; tread depth already at 10"). Inspector Comments: 06/22/2015FailQuinton OwensCommercial Sheetrock/Drywall Inspection Missing some screws on ceiling in shower room 218. Partial approval to tape already hung drywall, but NOT to cover framing corrections until approved. Inspector Comments: 06/23/2015FailQuinton OwensCommercial Sheetrock/Drywall Inspection Second floor drywall approved for taping. Thermal protection separating foam insulation to interior of building required. Inspector Comments: 06/30/2015PassQuinton OwensCommercial Insulation Inspection Exterior insulation on first floor approved (Framing inspection not approved on 1st floor). Inspector Comments: 07/09/2015FailQuinton OwensCommercial Sheetrock/Drywall Inspection Fire barrier incomplete on main level and horizontal assembly rating not completed. Drywall approved only at non-rated partitions. Inspector Comments: 07/16/2015FailQuinton OwensCommercial Sheetrock/Drywall Inspection Fire barrier on main level between R and B occupancies is completed. Rated ceiling attached to wood joists still not approved. Main level walls approved for taping. Partial drywall only approved. Fire rate penetrations under residential area and have inspected. Inspector Comments: 07/16/2015FailQuinton OwensCommercial Framing/Structure Inspection Lower level framing approved. Fire rated separation with single layer drywall at wood joists is not approved. Add second layer or find listed one hour assembly that matches the installed floor/ceiling. Inspector Comments: 07/21/2015FailQuinton OwensCommercial Insulation Inspection Thermal barrier using mineral wool insulation over foam insulation completed on west and south walls and above sleeping rooms of upper level. Approved to hang ceiling in these areas. Foam insulation above north rooms adjoining kitchen area is intended to receive ignition barrier of intumescent paint as discussed. (Call for Inspection when done) Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 14-00370 26 N Center St - Madison Fire Station - Addition & Remodel 26 N Center St Commercial Addition Permit Status of (Open) as of Report Date: 06/26/2019 3:27 pm Permit Inspection Summary 07/27/2015PassQuinton OwensCommercial Sheetrock/Drywall Inspection Upper ceiling and perimeter wall inspection for rated penetrations in rooms connected to south garage only. Approved to hang lower rated ceiling in these rooms. Penetrations also fire caulked in other area under 2nd level floor joists. Approved to proceed with rating the main level ceiling as discussed with double layer rated drywall in east storage room and intumescent paint in remaining area of wood joists. Inspector Comments: 08/07/2015PassQuinton OwensCommercial Sheetrock/Drywall Inspection Fire rated ceiling under R2 portion of buildig: 2nd layer added where available. Rest of rated ceiling painted with intumescent paint as submitted. Inspector Comments: 08/07/2015PassQuinton OwensCommercial Insulation Inspection Foam insulation over pantries sprayed with intumescent paint for an ignition barrier as discussed. Inspector Comments: 10/02/2015FailQuinton OwensCommercial Building Final Fire rate penetrations under sinks in kitchen area, in wall behind laundry (including around dryer vents), penetrations from ambulance bay in fire rated wall, and electrical penetration in wall above access panel in bathroom. Access to inspect fire caulking at top of column and south wall on main floor rated ceiling. None of the glass in the fire rated doors is fire rated. Fire rate gaps between stair enclosure and area under stairs. Ceiling radiation dampers missing in vents penetrating rated ceiling in rooms off of fire truck bay. Finish fire rating ceiling penetrations in shop room. Fire door frames are not labeled as per 716.5.7.4 (laundry room door frame has no label). Note: Exhaust vent cap missing on roof of ambulance bay. Inspector Comments: 10/20/2015FailQuinton OwensCommercial Building Final Fire rated glazing for rated doors is on order. Suppose to arrive in a week. Call for re-inspect as soon as they are installed. OK for 2 week temporary C.O. Inspector Comments: 10/20/2015PassQuinton OwensCommercial Sheetrock/Drywall Inspection Gap between rated ceiling and south block wall and around column penetration between restroom and hall has been fire caulked. Inspector Comments: 10/20/2015PassQuinton OwensCommercial Framing/Structure Inspection 11/06/2015FailQuinton OwensCommercial Building Final Missed fire rated glazing in west door going into fire truck bay.Inspector Comments: 01/29/2016PassQuinton OwensCommercial Building Final No re-inspection called in. Inspected on later visit to fire station. Fire rating installed in west door to south garage done. Inspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 14-00370 26 N Center St - Madison Fire Station - Addition & Remodel 26 N Center St Commercial Addition Permit Status of (Open) as of Report Date: 06/26/2019 3:27 pm Permit Inspection Summary Electrical Inspection Type 05/13/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 05/26/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 06/25/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 08/04/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 09/15/2015FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection 10/05/2015FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection 02/05/2016PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Fire Inspection Type 06/08/2015PassDale PickeringFire Sprinkler Rough-in Rough-in for 2nd floor only, PassInspector Comments: 06/25/2015PassDale PickeringFire Sprinkler Rough-in 09/03/2015PassDale PickeringFire Sprinkler Final Inspection 09/15/2015FailBret StoddardFire Alarm Final Inspection 10/05/2015PassBret StoddardFire Alarm Final Inspection Mechanical Inspection Type 05/21/2015FailDon AllenHVAC Rough-in need to finish the roughinInspector Comments: 09/25/2015PassDon AllenHVAC Final Inspection good for the c/oInspector Comments: Plumbing Inspection Type 11/25/2014PassDon AllenPlumbing Underground Inspection 05/06/2015PassDon AllenPlumbing Rough-in THE PLUMBING ROUGHIN ON THE 2ND FLOOR PASSED TEST AND CAN BE COVERED Inspector Comments: 05/21/2015PassDon AllenPlumbing Rough-in 09/25/2015PassDon AllenPlumbing Final Inspection good for the c/oInspector Comments: Page 4 of 4