Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00274 - 141 S 1st W - Chick-fil-A Tenant FinishPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/21/2019 8:25 am Permit Details Permit Number: 14-00274 141 S 1st W - Chick-fil-A Tenant Finish 141 S 1st W Commercial Remodel Permit Issued Date: 07/16/2014 Permit Inspection Statistics 17Total Inspections Completed: 11Total Inspections Passed: Inspection Pass Rate: 64.71% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 08/04/2014PassQuinton OwensCommercial Framing/Structure Inspection 09/02/2014FailQuinton OwensCommercial Building Final Building Final approved, but hood system not tested yet (air flow and ansul system) and grease collector not installed in hood. Inspector Comments: 09/08/2014N/AQuinton OwensCommercial Insulation Inspection 09/10/2014FailQuinton OwensCommercial Building Final Grease collector for kitchen hood not installed (missing - new one ordered). Need report on kitchen hood flow rate. Final only good for Temp. C.O. Inspector Comments: 09/19/2014PassQuinton OwensCommercial Building Final Electrical Inspection Type 08/04/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 08/27/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 09/02/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Fire Inspection Type 09/19/2014N/ADale PickeringFire Sprinkler Rough-in Page 1 of 2 (Continued) Permit Details Permit Number: 14-00274 141 S 1st W - Chick-fil-A Tenant Finish 141 S 1st W Commercial Remodel Permit Status of (Open) as of Report Date: 06/21/2019 8:25 am Permit Inspection Summary Mechanical Inspection Type 08/19/2014FailQuinton OwensHVAC Rough-in Grease duct inspection: 4 holes found to be re-welded (2 in larger duct, 2 in smaller duct). Duct should be ready for reinspect later afternoon or early morning. Inspector Comments: 08/20/2014PassQuinton OwensHVAC Rough-in Previous 4 holes repaired and approved. Another small section with two turns inspected on ground and approved. Must Reinspect all final connections to hoods when installed. Inspector Comments: 08/25/2014FailQuinton OwensHVAC Rough-in Last connections of grease duct to kitchen hood. Several holes found.Inspector Comments: 08/26/2014PassQuinton OwensHVAC Rough-in Last grease duct connections approved. Okay to finish duct wrap.Inspector Comments: 08/29/2014PassDon AllenHVAC Final Inspection all good for the c/o ducting looked goodInspector Comments: Plumbing Inspection Type 07/31/2014PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 08/25/2014PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 09/04/2014PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Page 2 of 2