HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00259 - 859 W Main St - MaverikPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 06/20/2019 11:16 am
Permit Details Permit Number: 14-00259
Maverik
859 West Main Street
Building - Commercial
Permit Issued Date: 09/03/2014
Permit Inspection Statistics
32Total Inspections Completed:
31Total Inspections Passed:
Inspection Pass Rate: 96.88%
Permit Inspection History *Refer to Individual Inspection Report for more Details
01/06/2015PassJoel GrayPublic Works Final Inspection
Sanitary Sewer manhole to be raised to grade by Jan.8.Inspector Comments:
01/06/2015PassNatalie PowellPlanning and Zoning Final Inspection
Building Inspection Type
09/11/2014PassTed DyeCommercial Footing Inspection
5 Square footings for the canopy.
Poured in lifts.
Inspector Comments:
09/16/2014PassQuinton OwensCommercial Footing Inspection
Footing rebar size and placement as per plans. Vertical dowels also sized and
spaced as required. Questioned dowels along grid G from grid 2.2 to 3 for being
lined up at an angle. Sub-contractor said they will have clearance as needed.
No details found for piers at footings F2 and F3 (6-#5 dowels added at F2 & 8 #5
dowels added at F3)
Inspector Comments:
09/17/2014PassQuinton OwensFoundation Inspection
Foundation rebar installed per plans. Piers at F2 & F3 have 8 #5 rebar ties
around vertical bars.
Inspector Comments:
10/23/2014PassQuinton OwensCommercial Insulation Inspection
Inspected insulation on west side where coolers go and east side of building.Inspector Comments:
10/30/2014PassQuinton OwensCommercial Framing/Structure Inspection
Inspected west and east exterior walls that will be covered by refrigeration units.Inspector Comments:
10/31: Sheathing not complete at framing inspection.Inspector Comments:
10/31/2014PassQuinton OwensCommercial Framing/Structure Inspection
Sheathing inspected and corrections made around mid November before EIFS
installed.
Inspector Comments:
12/24/2014FailQuinton OwensCommercial Building Final
Fix side grab bar in women's restroom, install handicap parking signs.Inspector Comments:
01/06/2015PassQuinton OwensCommercial Building Final
Handicap signs installed and side grab bar for handicap stall was corrected.Inspector Comments:
01/06/2015PassQuinton OwensSidewalk Inspection
sidewalk at street existing. pedestrian paths and sidewalks on side are done.Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 14-00259
Maverik
859 West Main Street
Building - Commercial
Permit Status of (Open) as of Report Date: 06/20/2019 11:16 am
Permit
Inspection
Summary
Electrical Inspection Type
09/24/2014PassBret StoddardElectrical Underground Inspection
09/25/2014PassBret StoddardElectrical Underground Inspection
09/25/2014PassBret StoddardElectrical Underground Inspection
10/01/2014PassBret StoddardElectrical Underground Inspection
10/14/2014PassBret StoddardElectrical Underground Inspection
10/21/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in
10/30/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in
11/05/2014PassBret StoddardCommercial Electrical Rough-in
11/07/2014PassBret StoddardCOM & MFR Electrical Service Inspection
12/09/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in
12/24/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved per Gabe Madrid.Inspector Comments:
Fire Inspection Type
10/29/2014PassDale PickeringFire Department Inspection
Fuel tanks 5lb test-Pass
Underground/sump-Pass
Inspector Comments:
10/29/2014PassDale PickeringFire Department Inspection
Underground piping/leak test on dispenser sumps -PassInspector Comments:
12/15/2014PassDale PickeringFire Department Inspection
12/12 Emergency shut-off, Pass; Shear valves properly installed, Pass; Sump
connections, Pass; DP
Inspector Comments:
01/06/2015PassDale PickeringFire Department Final Inspection
Mechanical Inspection Type
11/03/2014PassDon AllenHVAC Rough-in
mechanical rough in looks goodInspector Comments:
12/24/2014PassDon AllenHVAC Final Inspection
Good for the c/oInspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 14-00259
Maverik
859 West Main Street
Building - Commercial
Permit Status of (Open) as of Report Date: 06/20/2019 11:16 am
Permit
Inspection
Summary
Plumbing Inspection Type
09/30/2014PassDon AllenPlumbing Underground Inspection
All good to cover the undergroundInspector Comments:
11/03/2014PassDon AllenPlumbing Rough-in
11/03/2014PassDon AllenWater Meter Inspection
Water meter looks good will check for final grade on barrel at the finalon the
building
Inspector Comments:
12/24/2014PassDon AllenPlumbing Final Inspection
Good for the c/oInspector Comments:
Page 3 of 3