Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 14-00401 - 594 Terra Vista Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/20/2019 9:24 am Permit Details Permit Number: 14-00401 594 Terra Vista Dr - SFR 594 Terra Vista Dr Building - Single Family Residence Permit Issued Date: 09/19/2014 Permit Inspection Statistics 21Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 71.43% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 09/22/2014PassTed DyeResidential Footing Inspection 09/24/2014Pass Foundation Inspection 12/02/2014FailTed DyeSheeting Some sheeting missed being nailed to the studs. Those studs are marked with green paint. Those area's can be inspected when the framing inspection is done. Inspector Comments: 12/12/2014FailTed DyeResidential Framing/Structure Inspection 12/15/2014FailTed DyeResidential Framing/Structure Inspection 12/17/2014PassTed DyeResidential Insulation Inspection 12/30/2014PassTed DyeResidential Sheetrock/Drywall Inspection inspection date shows 12-30-14 but should be 12 23-14.Inspector Comments: 02/05/2015Fail Residential Building Final Finish gaurd rail and the level landing at the bottom of the front steps then call for a re-inspection Inspector Comments: 02/13/2015FailTed DyeResidential Building Final Before occupying the building a temp drive way should be put in place.Inspector Comments: 05/06/2015PassTed DyeSidewalk Inspection 10/29/2015PassTed DyeResidential Building Final Electrical Inspection Type 12/12/2014PassBret StoddardResidential Electrical Service Inspection Rocky Mountain Power Work Order # 5962485Inspector Comments: 12/12/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 02/05/2015PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 14-00401 594 Terra Vista Dr - SFR 594 Terra Vista Dr Building - Single Family Residence Permit Status of (Open) as of Report Date: 06/20/2019 9:24 am Permit Inspection Summary Mechanical Inspection Type 12/12/2014FailDon AllenHVAC Rough-in the return air on the furnace is covering the back flow device that the plumber installed in the floor. need to have acess to that devic for maintenance. Inspector Comments: 02/05/2015PassDon AllenHVAC Rough-in return air is off the backwater valve.Inspector Comments: 02/05/2015PassDon AllenHVAC Final Inspection Good for the c/oInspector Comments: Plumbing Inspection Type 10/09/2014PassDon AllenPlumbing Underground Inspection 10/13/2014PassDon AllenPlumbing Sewer all good to cover the sewerInspector Comments: 12/10/2014PassDon AllenPlumbing Rough-in All good to cover the plumbing rough inInspector Comments: 02/05/2015PassDon AllenPlumbing Final Inspection Page 2 of 2