HomeMy WebLinkAboutPLANS PLUMBING & MECHANICAL - 14-00529 - 18 N 2nd E - Mountain America Credit UnionPL
U
M
B
I
N
G
SC
H
E
D
U
L
E
S
,
DE
T
A
I
L
S
,
&
GE
N
E
R
A
L
N
O
T
E
S
P001
SH
E
E
T
T
I
T
L
E
:
SHEET NUMBER:
PR
O
J
E
C
T
:
SE
A
L
:
TH
I
S
D
R
A
W
I
N
G
I
S
C
L
A
S
S
I
F
I
E
D
A
S
PA
R
T
O
F
A
N
U
N
P
U
B
L
I
S
H
E
D
CO
L
L
E
C
T
I
O
N
O
F
V
I
S
U
A
L
A
R
T
.
UN
D
E
R
T
H
E
1
9
7
8
C
O
P
Y
R
I
G
H
T
AC
T
,
I
T
I
S
A
N
E
X
C
L
U
S
I
V
E
OR
I
G
I
N
A
L
W
O
R
K
O
F
AU
T
H
O
R
S
H
I
P
.
N
O
N
E
O
F
T
H
E
PIC
T
O
R
I
A
L
,
G
R
A
P
H
I
C
O
R
TE
C
H
N
I
C
A
L
C
H
A
R
T
S
O
R
DR
A
W
I
N
G
S
D
E
P
I
C
T
E
D
O
N
T
H
I
S
SH
E
E
T
M
A
Y
B
E
R
E
P
R
O
D
U
C
E
D
OR
T
R
A
N
S
M
I
T
T
E
D
I
N
A
N
Y
F
O
R
M
OR
B
Y
A
N
Y
M
E
A
N
S
W
I
T
H
O
U
T
T
H
E
EX
P
R
E
S
S
P
R
I
O
R
W
R
I
T
T
E
N
PE
R
M
I
S
S
I
O
N
O
F
T
H
E
A
R
C
H
I
T
E
C
T
.
TH
I
S
P
L
A
N
I
S
P
R
O
D
U
C
E
D
O
N
L
Y
FO
R
T
H
I
S
P
R
O
J
E
C
T
O
N
T
H
I
S
S
I
T
E
AN
D
M
A
Y
N
O
T
B
E
U
S
E
D
A
T
OT
H
E
R
L
O
C
A
T
I
O
N
S
.
RE
V
DA
T
E
DE
S
C
R
I
P
T
I
O
N
DO NOT SCALE DRAWING
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
4123 5 6
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
d
a
t
e
:
1
1
/
1
7
/
1
4
RE
X
B
U
R
G
,
I
D
PR
O
J
E
C
T
:
RE
X
B
U
R
G
B
R
A
N
C
H
CO
R
N
E
R
O
F
2
N
D
&
M
A
I
N
S
T
.
MO
U
N
T
A
I
N
A
M
E
R
I
C
A
C
R
E
D
I
T
U
N
I
O
N
em
a
a
r
c
h
i
t
e
c
t
s
│29
0
9
W
A
S
H
I
N
G
T
O
N
B
L
V
D
-
O
G
D
E
N
,
U
T
8
4
4
0
1
│PH
:
8
0
1
-
6
1
8
-
3
4
6
3
GENERAL PLUMBING NOTES
1. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE, OPERATIONAL
PLUMBING SYSTEM FOR THE ENTIRE PROJECT AS SHOWN ON THESE DRAWINGS, INCLUDING ALL NECESSARY
FEES AND PERMITS.
2. THE ENTIRE INSTALLATION SHALL CONFORM TO THE MOST RECENTLY ADOPTED REQUIREMENTS OF THE
INTERNATIONAL MECHANICAL CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL BUILDING CODE, AND ALL
OTHER APPLICABLE CITY, COUNTY, AND STATE CODES AND REGULATIONS IN EFFECT AT THE DATE
OF THE PERMITTING.
3. PRIOR TO FABRICATION AND INSTALLATION THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL
PLUMBING PIPING, DUCTWORK, AND EQUIPMENT WITH PLUMBING PIPING, PLUMBING EQUIPMENT, ALL
DUCTWORK, AND ALL OTHER TRADES INCLUDING BUT NOT LIMITED TO THE MECHANICAL CONTRACTOR,
ELECTRICAL CONTRACTOR, GENERAL CONTRACTOR, AND ANY CONTRACTOR HIRED DIRECTLY BY THE OWNER.
WHERE CONFLICTS MAY OCCUR, THEY SHALL BE RESOLVED PRIOR TO INSTALLATION.
4. THE DRAWINGS SHOW THE GENERAL DESIGN, ARRANGEMENTS AND THE EXTENT OF THE SYSTEM. IT
SHALL BE THE WORK OF THE CONTRACTOR TO MAKE SUCH SLIGHT ALTERATIONS AS MAY BE NECESSARY TO
MAKE THE SYSTEM COMPLETE AND OPERATIONAL IN ACCORDANCE WITH THE DESIGN INTENT. MAJOR
DEVIATIONS SUCH AS CHANGES IN COMPONENT SIZES, WEIGHTS, QUANTITIES, OR MATERIAL REQUIRE PRIOR
APPROVAL BY THE CONSULTING ENGINEER.
5. ALL PLUMBING INFORMATION IS NOT SHOWN ON THE PLUMBING DRAWINGS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR COORDINATING INFORMATION ON ALL OTHER CONSTRUCTION DOCUMENTS INCLUDING
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.
6. THE WORKING DRAWINGS ARE DIAGRAMMATIC. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THEY
DO NOT SHOW EVERY OFFSET, BEND OR ELBOW NECESSARY FOR THE COMPLETE INSTALLATION IN THE
SPACE PROVIDED. ALL LOCATIONS FOR PLUMBING EQUIPMENT AND PIPING SHALL BE CHECKED AND
COORDINATED WITH THE ARCHITECTURAL, MECHANICAL, STRUCTURAL AND ELECTRICAL DRAWINGS.
7. EXACT ROUTING OF WASTE, GAS, AND WATER SERVICE IS DEPENDENT ON LOCAL SITE CONDITIONS AND
MODIFICATIONS IN EQUIPMENT CONNECTIONS. EXACT LOCATION OF EQUIPMENT MAY VARY DEPENDING ON
LOCAL CODE, HEALTH DEPARTMENT AND CITY REQUIREMENTS.
8. DETAILS: THE CONTRACTOR IS RESPONSIBLE TO REVIEW AND USE WHERE APPROPRIATE ALL OF THE
PLUMBING DETAILS SHOWN ON THE DRAWINGS. DETAILS MAY OR MAY NOT BE CALLED OUT ON THE
DRAWINGS WITH SYMBOLS OR KEYED NOTES. ANY CHANGES RESULTING FROM FAILURE TO INSTALL THE
PLUMBING SYSTEM WITHOUT USING THE INCLUDED DETAILS IS THE RESPONSIBILITY OF THE CONTRACTOR.
9. THE DRAWINGS AND SPECIFICATIONS HAVE BEEN PREPARED TO SUPPLEMENT EACH OTHER AND THEY SHALL
BE INTERPRETED AS AN INTEGRAL UNIT WITH THE ITEMS SHOWN ON ONE AND NOT THE OTHER BEING
FURNISHED AND INSTALLED AS THOUGH SHOWN AND CALLED OUT IN BOTH.
10. PREPARE 6 COPIES OF SUBMITTALS IN AN INDEXED, LABELED FOLDER CONTAINING FULL PERFORMANCE,
MATERIAL AND INSTALLATION INFORMATION ABOUT ALL EQUIPMENT, PIPING, COMPONENTS AND ACCESSORIES
TO BE USED.
11. THE STRUCTURE SHOWN ON ALL DETAILS MAY OR MAY NOT PERTAIN TO A PORTION OR ANY PORTION
OF THE BUILDING. COORDINATE MOUNTING REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
12. ANY PART OF THIS INSTALLATION THAT FAILS, IS UNFIT, OR BECOMES DAMAGED DURING CONSTRUCTION
SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
13. ALL EQUIPMENT SHALL PROVIDE THE SCHEDULED PERFORMANCE AT THE SITE ALTITUDE.
14. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S
RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, VALVES, AND OTHER DEVICES AND ACCESSORIES
REQUIRED FOR A COMPLETE, WORKABLE INSTALLATION.
15. ALL MOTORS REQUIRED SHALL BE BY THE DIVISION 15 CONTRACTOR. ALL MOTOR STARTING EQUIPMENT,
IF NOT A PART OF THE EQUIPMENT, IS FURNISHED BY THE ELECTRICAL CONTRACTOR.
16. THE CONTRACTOR IS RESPONSIBLE FOR PLUMBING EQUIPMENT CHECK-IN, SAFEKEEPING, AND DAMAGE.
17. INVERTS SHOWN ON PLUMBING DRAWINGS MAY BE REFERENCED FROM THE FINISHED FLOOR ELEVATION.
COORDINATE ALL INVERTS WITH CIVIL DRAWINGS PRIOR TO INSTALLATION.
18. PROVIDE WALL CLEANOUTS IN ALL VENTS FOR COMBINATION WASTE AND VENT SYSTEMS AS REQUIRED BY
LOCAL AND NATIONAL CODES.
19. ALL VENT FITTINGS FOR WASTE SYSTEMS BELOW OVERFLOWS OF FIXTURES SHALL BE DRAINAGE TYPE.
20. CONTRACTOR TO COMPLY WITH THE LATEST ADOPTED IPC WHEN SIZING TRAP ARMS ON COMBINATION
WASTE AND VENT SYSTEMS. THE DRAWINGS INDICATE THE WASTE LINE SIZE AND THE SIZE OF THE TRAP
REQUIRED.
21. PROVIDE CLEANOUTS IN ACCORDANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. FLOOR
CLEANOUTS SHALL BE LOCATED OUT OF TRAFFIC AREAS.
22. LOCATE ALL PLUMBING VENTS AT LEAST 3 FEET ABOVE OR 10 FEET AWAY FROM ALL OUTSIDE AIR
INTAKES INTO THE BUILDING.
23. SEE "PLUMBING FIXTURE SCHEDULE" FOR FIXTURE MAKE AND TYPE, AND SIZE OF INDIVIDUAL WASTE,
VENT, AND DOMESTIC WATER PIPING TO FIXTURES.
24. ALL PLUMBING EQUIPMENT SHALL BE LISTED AND LABELED BY AN APPROVED TESTING AGENCY.
25. EQUIPMENT AND INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION (NSF) STANDARDS, OR
EQUIVALENT.
26. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING.
27. ALL PIPE SHALL BE SECURED BY DOUBLE NUTTING AT THE HANGER ROD ATTACHMENT TO THE
STRUCTURE, AND AT THE PIPE HANGER.
28. PROVIDE WATER HAMMER ARRESTORS (SHOCK ABSORBERS) AT ALL PIPE LOCATIONS WHERE VALVE
CLOSURES (SUCH AS FLUSH VALVES) MAY CAUSE WATER HAMMER OR RESULT IN EXCESSIVE PIPE VIBRATION
OR MOVEMENT.
29. PROPERLY LUBRICATE ALL PIECES OF EQUIPMENT BEFORE TURNING THE SYSTEM OVER TO THE OWNER.
30. TWO OPERATING AND MAINTENANCE MANUALS SHALL BE PROVIDED IN HARD BACK LOOSE LEAF BINDERS.
MANUALS SHALL CONTAIN PRODUCT CUT SHEETS AND OPERATING AND MAINTENANCE INSTRUCTIONS ON ALL
EQUIPMENT, ACCESSORIES, FIXTURES, VALVES, ETC., PROVIDED FOR THE PROJECT.
31. UPON COMPLETION OF THE WORK, REMOVE ALL SURPLUS MATERIALS AND RUBBISH. MAKE ALL
REQUIRED PATCHING AND REPAIRS OF OTHER TRADES' WORK DAMAGED BY THIS CONTRACTOR, AND LEAVE
THE PREMISES IN A CLEAN, ORDERLY CONDITION.
32. THE CONTRACTOR SHALL OPERATE THE SYSTEM AND DEMONSTRATE ALL ASPECTS TO THE ENGINEER
AND/OR OWNER, TO PROVE ITS OPERATION.
33. THE CONTRACTOR SHALL GUARANTEE THE PLUMBING SYSTEM FOR A PERIOD OF ONE YEAR FROM THE
DATE OF SUBSTANTIAL COMPLETION.
34. THE CONTRACTOR SHALL, DURING CONSTRUCTION, MAINTAIN A SET OF AS-BUILT REDLINED RECORD
DRAWINGS AT THE PROJECT SITE. ALL CHANGES IN LAYOUT, ROUTING, EQUIPMENT, COMPONENTS, AND
ACCESSORIES SHALL BE RECORDED. THESE REDLINES SHALL BE GIVEN TO THE ARCHITECT/ENGINEER AFTER
THE FINAL INSPECTION.
SHUT OFF (BALL VALVE TYPE)
PRESSURE REDUCING VALVE (GAS OR WATER)
LIQUEFIED PETROLEUM GASLP
PLUMBING LEGEND
POINT OF CONNECTION
KEYED NOTE CALLOUT
POINT OF DEMOLITION
FIXTURE CALLOUT
SECTION CALLOUT
TITLE
SECTION
SHEET #
FLOOR DRAIN
FLOOR SINK
TEE
ROOF DRAIN
OVERFLOW ROOF DRAIN
BOTTOM CONNECTION
TOP CONNECTION
CAP OR PLUG
PIPE BREAK
DIRECTION OF FLOW
DIRECTION OF PIPE SLOPE
CW
HW POTABLE HOT WATER PIPE
POTABLE COLD WATER PIPE
SS SANITARY SEWER PIPE
POTABLE HOT WATER RETURN PIPEHWR
GW
GW
GREASE WASTE LINE ABOVE GRADE
GREASE WASTE LINE
V
VTRVTR
RD
ORD
RD
ORD OVERFLOW ROOF DRAIN LINE
ROOF DRAIN LINE
VENT THROUGH THE ROOF
VENT LINE
SANITARY SEWER PIPE BELOW GRADESS
RD
G NATURAL GAS LINE
ROOF DRAIN LINE BELOW GRADE
FIRE SPRINKLER RISER
HAMMER ARRESTOR
FIRE DEPARTMENT CONNECTION
HOSE BIBB WITH SHUT OFF
TRAP PRIMER
TWO WAY CLEAN OUT TO GRADE2-WAY COTG
FCO
CO
WCO
FLOOR CLEANOUT
WALL CLEANOUT
EXPOSED CLEANOUT
COTG CLEANOUT TO GRADE
FCO
WCO
CO
COTG
COTG
2-WAY
PIPE RISE
PIPE DROP
ORD
RD
FD
FS
ENLARGED PLUMBING
DETAIL CALLOUTDETAIL #
SHEET #
EQUIPMENT CALLOUT
BACK FLOW PREVENTER
PSI18.0
PSI25.0
PSI32.0
PSI23.0
PSI2
PSI7
75 PSI
41
0
0
GPM
GPM
GPM
41
BUILDING WATER SUPPLY CALCULATIONS
TOTAL FIXTURE UNITS:
ESTIMATED DEMAND:
IRRIGATION DEMAND:
HVAC DEMAND:
TOTAL DEMAND:
PRESSURE AVAILABLE AT STREET MAIN:
PRESSURE LOSS DUE TO HEIGHT ( FT. x 0.434):
PRESSURE LOSS THROUGH METER:
PRESSURE LOSS THROUGH OTHER DEVICES:(i.e. Water Softener, Filters, Backflow Preventer, PRV)
TOTAL PRESSURE LOSS (Add lines 2 thru 4):
PRESSURE REQUIRED AT HIGHEST FIXTURE:
PRESSURE AVAILABLE FOR FRICTION LOSS:(Subtract lines 5 & 6 from line 1)
1.
2.
3.
4.
5.
6.
7.
HORIZONTAL PIPE LENGTH:
VERTICAL PIPE LENGTH:
EQUIVALENT FITTING LENGTH:
TOTAL DEVELOPED LENGTH:
FRICTION LOSS CALCULATION:(Line 7 / Line 11) x 100
DOMESTIC WATER SERVICE SIZE:
WATER METER SIZE:
BUILDING SEWER SIZE:
8.
9.
10.
11.
12.
DE
M
A
N
D
S
PR
E
S
S
U
R
E
L
O
S
S
E
S
FR
I
C
T
I
O
N
L
O
S
S
SU
M
M
A
R
Y
WATER SUPPLY:WASTE:24
GPM
16
FT145
FT25
FT20
100
29
FT
(/100 FT)12.4
1-1/2"DIA.
DIA.1"
DIA.4"
TOTAL (CFH) =
BTU/CUBIC FT. =
231123
SECTION
SPECIFICATION
TOTAL
INPUTEQUIPMENTLOCATIONEQUIP.
NO.
TOTAL (BTUH) =
GAS PRESSURE IN BUILDING
PIPE SIZE AT METER
QTY.MBH
INPUT
NATURAL GAS REQUIREMENTS
RTU-1
1
1 ROOF
ROOF
ROOFTOP UNIT 180,000
RTU-2 ROOFTOP UNIT
DESIGN LENGTH 90'
4 OZ
1 1/4"
245,000
1000
245
65,000
180,000
65,000
RECIRCULATION PUMP
WASTE
PLUMBING FIXTURE SCHEDULE
SYMBOL FIXTURE WATER
COLD
WATER
HOT VENT ACCESSORIES
AND REMARKSTRAP
FLOOR MOUNTED, FLUSH VALVE2"4"---1"WATER CLOSET (ADA COMPLIANT)WC-2 INT.
1-1/2"S-1 SINK - SINGLE COMPARTMENT 1/2"1/2"1-1/2"1-1/2"COUNTER MOUNTED SINGLE COMPARTMENT
HB-1
3"SS-1 SERVICE SINK 1/2"1/2"3"2"FLOOR MOUNTED WITH DEEP SEAL TRAP
2"FD-2 FLOOR DRAIN ------2"2"WITH DEEP SEAL TRAP
FREEZELESS---------3/4"HOSE BIBB (ENCASED)---
3"FD-3 FLOOR DRAIN ------3"2"WITH DEEP SEAL TRAP
1-1/4"L-1 LAVATORY (ADA COMPLIANT)1/2"1/2"1-1/4"1-1/4"COUNTER MOUNTED, ADA COMPLIANT
PROVIDE WATTS USG-B THERMOSTATIC TEMPERING VALVE UNDER COUNTER TO EACH LAV.
ELECTRIC WATER COOLER, WALL HUNG, 8 GPH, ADA WHEELCHAIR1-1/2"1-1/2"---1/2"WATER COOLER (ADA WHEELCHAIR)DF-1 1-1/2"
RD-4 ROOF DRAIN 4"------------
PROVIDE WITH 4" DAMORD-4 OVERFLOW ROOF DRAIN 4"------------
SPECIFICATION
SECTION 224000,
221119, 221319, 221423
---TS ------------JAY R SMITH QUAD CLOSE TRAP SEALTRAP SEAL
---WATER HAMMER ARRESTOR 3/4'---------12-32 FIXTURE UNITSHA-3/4
---------1/2"ICE MAKER CONNECTIONIM-1 ---
ELECTRIC WATER HEATER SCHEDULE
(GAL.)
CAPACITY
STORAGE
EWH-1
SYMBOL
BRADFORD WHITE LD-WH20L3-1 STORAGE
TYPE
(LBS.)
WEIGHT
59
OPERATINGINPUTRECOVERY
CAPACITY
19 6
RATE
(GPH)
VOLTS/Ø/HZ.
1.5
(KW)
120/1/60
WATER
40° - 140°
IN/OUT
TEMP.
22"Ø x 47.5"
SIZE
OVERALL
2 GALLON EXPANSION TANK, WALL HANGING KIT
MANUFACTURER
AND MODEL NO.
ACCESSORIES
AND REMARKS
SPECIFICATION
SECTION
223300
------------3"OVERFLOW ROOF DRAINORD-3 PROVIDE WITH 4" DAM
------------3"ROOF DRAINRD-3
GW
3
RD
RD
ORD
1
HB-1
WHID
1
1
A301
2
SCALE: 1/4" = 1' - 0"
A301
2
BP
BALANCING VALVES
TEMPERING VALVE
MAY EXTEND AS A WASTE OR VENT LINE
FINISHED FLOOR
1/8" C.I. BEND
REFERENCED ON DRAWING AS "WCO"
BALANCE OF PIPING SAME AS CLEANOUT TOGRADE
PLUGGED TEE WITH
CLEANOUT
CHROME WALL COVER AND SCREW
WALL
FINISHED GRADE
18"x18"x6" THICK CONCRETE PAD
C.I. PIPE (SIZE AS SHOWN ONDRAWINGS)
4" C.I. PIPE
CEMENT PATCH
4" C.I.
CLEANOUT PLUG
C.I. COVER AND FRAME
6" MIN.
VARIES
1'-0"1'-0"
6" LAYERS OF SAND, COMPACTABLE SOIL, OR APPROVED GRAVEL
PLACED AND COMPACTED 95% MIN. DRY DENSITY AASHTO T-180
CONCRETE SLAB
FINISHED FLOOR
CONCRETE (TYP.)
USE CAULKED OUTLET TYPE
CONNECTION.
DEEP SEAL P-TRAP
WATERPROOF MEMBRANE
FLASHED INTO CLAMPING
COLLAR.
ADJUSTABLE HEAD SET FLUSH WITH
FINISHED FLOOR
SLOPE SLOPE
HANGER ROD
DOUBLE NUT CLEVIS HANGER
TO ROD
PIPE INSULATION
RIGID INSULATION AT SUPPORT
22 GAUGE SHEET METAL INSULATION
SHIELD - 12" LONG
CARRIER PIPE
CLEVIS HANGER
12
"
10
"
12" MIN.
ROOFING
ROOF DECKVENT
FLASHING
STAINLESS STEEL CLAMP
SEALANT
ACCESS FRAME AND COVER TOP OF COVER SHALL BEFLUSH WITH TOP OF FLOOR
COUNTERSUNK SCREW
CAST IRON 1/8
BEND
1/8 BEND IF CLEANOUT OCCURS AT END OF LINE
WASTE PIPING
BALANCE OF PIPING SAME AS
CLEANOUT TO GRADE
FINISHED FLOOR
BRASS CLEANOUT PLUG AND FERRULE 1"
REDUCED PRESSURE BACKFLOW PREVENTOR. PROVIDE INLET AND OUTLET SHUT-
OFF VALVES AND 4 TEST COCKS. (MAY BE SUBSTITUTED WITH DOUBLE CHECK
ASSEMBLY IF APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION)
TO POTABLE WATERSYSTEM
GLOBE VALVE
PRESSURE GAGE (TYP)
UNION (TYP)
BALL VALVE (TYP)
PRESSURE REDUCING VALVE TO HANDLE --- GPM @ 65 PSI
DISCHARGE PRESSURE
STRAINER WITH
BLOWDOWN
INCOMING WATER SERVICE SLEEVE CONCRETE FLOOR
12" MINIMUM
ABOVE FLOOR
R
VACUUM RELIEF VALVE
EXPANSION TANK
BALL VALVE
COLD WATER SUPPLY
P&T RELIEF VALVE
DRAIN VALVE W/THREADED HOSE CONNECTION
DIELECTRIC UNION (TYPICAL)
HOT WATER
THERMOMETER
R
RUN DISCHARGE LINE TOSERVICE SINK
SUPPORT WITH FACTORY WALL HANGER
BRACE LINE TO WALL ANCHOR WATER HEATER TO WALL USE 1" X 18 GA.
STRAP WITH #10 X 2 1/2" WOOD SCREWS. TYPICAL OF TWO PLACES.
1 WALL CLEANOUT
SCALE: 1' = 1'-0"
2 CLEANOUT TO GRADE
SCALE: 1' = 1'-0"
6 PIPE UNDER SLAB
SCALE: 1' = 1'-0"
5 FLOOR DRAIN
SCALE: 1' = 1'-0"
3 INSULATED PIPE HANGER
SCALE: 1' = 1'-0"
4 VENT THRU ROOF (FLAT)
SCALE: 1' = 1'-0"
7 FLOOR CLEANOUT
SCALE: 1' = 1'-0"8 WATER PRESSURE REDUCING VALVE STATION
SCALE: 1' = 1'-0"9 ELECTRIC WATER HEATER WALL HUNG W/ BRACKET
SCALE: 1' = 1'-0"
4141
FL
O
O
R
&
R
O
O
F
PL
U
M
B
I
N
G
P
L
A
N
P101
SH
E
E
T
T
I
T
L
E
:
SHEET NUMBER:
PR
O
J
E
C
T
:
SE
A
L
:
TH
I
S
D
R
A
W
I
N
G
I
S
C
L
A
S
S
I
F
I
E
D
A
S
PA
R
T
O
F
A
N
U
N
P
U
B
L
I
S
H
E
D
CO
L
L
E
C
T
I
O
N
O
F
V
I
S
U
A
L
A
R
T
.
UN
D
E
R
T
H
E
1
9
7
8
C
O
P
Y
R
I
G
H
T
AC
T
,
I
T
I
S
A
N
E
X
C
L
U
S
I
V
E
OR
I
G
I
N
A
L
W
O
R
K
O
F
AU
T
H
O
R
S
H
I
P
.
N
O
N
E
O
F
T
H
E
PIC
T
O
R
I
A
L
,
G
R
A
P
H
I
C
O
R
TE
C
H
N
I
C
A
L
C
H
A
R
T
S
O
R
DR
A
W
I
N
G
S
D
E
P
I
C
T
E
D
O
N
T
H
I
S
SH
E
E
T
M
A
Y
B
E
R
E
P
R
O
D
U
C
E
D
OR
T
R
A
N
S
M
I
T
T
E
D
I
N
A
N
Y
F
O
R
M
OR
B
Y
A
N
Y
M
E
A
N
S
W
I
T
H
O
U
T
T
H
E
EX
P
R
E
S
S
P
R
I
O
R
W
R
I
T
T
E
N
PE
R
M
I
S
S
I
O
N
O
F
T
H
E
A
R
C
H
I
T
E
C
T
.
TH
I
S
P
L
A
N
I
S
P
R
O
D
U
C
E
D
O
N
L
Y
FO
R
T
H
I
S
P
R
O
J
E
C
T
O
N
T
H
I
S
S
I
T
E
AN
D
M
A
Y
N
O
T
B
E
U
S
E
D
A
T
OT
H
E
R
L
O
C
A
T
I
O
N
S
.
RE
V
DA
T
E
DE
S
C
R
I
P
T
I
O
N
DO NOT SCALE DRAWING
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
4123 5 6
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
d
a
t
e
:
1
1
/
1
7
/
1
4
RE
X
B
U
R
G
,
I
D
PR
O
J
E
C
T
:
RE
X
B
U
R
G
B
R
A
N
C
H
CO
R
N
E
R
O
F
2
N
D
&
M
A
I
N
S
T
.
MO
U
N
T
A
I
N
A
M
E
R
I
C
A
C
R
E
D
I
T
U
N
I
O
N
em
a
a
r
c
h
i
t
e
c
t
s
│29
0
9
W
A
S
H
I
N
G
T
O
N
B
L
V
D
-
O
G
D
E
N
,
U
T
8
4
4
0
1
│PH
:
8
0
1
-
6
1
8
-
3
4
6
3
REST113
REST112ADMIN
109
JANITOR
117
FD-2
TS
FD-2
TS
55
3" VTR
5
3/4"
1 1/2"
1 1/2"
2"
3/4"
3/4"3/4"
2"1/2"
3/4"
2"
2"
4"
2"
HA-3/4
WCO
5 5
4"
WCO
L-1 WC-2
WC-2L-1
DF-1
EWH-1
SS-1
4"
13
13TS
FD-3
BP
FOR CONTINUATION OF WATER SERVICE PIPING SEE
SITE PLAN.
FOR CONTINUATION OF WASTE LINE SEE SITE PLAN.
FOR CONTINUATION OF GAS LINE SEE SITE PLAN.
FOR CONTINUATION OF PIPING SEE PLUMBING
ENLARGEMENTS, DETAIL 2 SHEET P101.
FOR CONTINUATION OF PIPING SEE PLUMBING FLOOR
PLAN, DETAIL 1 SHEET P101.
FOR CONTINUATION OF ROOF DRAIN LINES SEE
PLUMBING ROOF PLAN, DETAIL 3 SHEET P101.
FOR CONTINUATION OF GAS PIPING SEE PLUMBING
ROOF PLAN, DETAIL 3 SHEET P101.
GAS METER SIZE FOR 245 CFH AT 4 OZ. METER AND
YARD LINE BY GAS COMPANY.
OVERFLOW ROOF DRAIN NOZZLE 12" ABOVE FINSH
GRADE.
FOR CONTINUATION OF ROOF DRAIN LINE SEE CIVIL
PLAN.
PENETRATE SIDE OF UNIT AT KNOCKOUT WITH GAS
PIPE, PROVIDE AND INSTALL A GAS SHUT-OFF VALVE
AND DIRT LEG AS CLOSE TO THE UNIT INLET AS
POSSIBLE ON OUTSIDE OF CABINET.
PIPE CONDENSATE FULL SIZE TO NEAREST ROOF
DRAIN.
RUN PIPING ABOVE CEILING
RUN PIPING BELOW FLOOR SLEEVE WATER PIPING
BELOW FLOOR.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
KEYED NOTES
NOTE:
FOR BRANCH SIZES TO INDIVIDUAL FIXTURES NOT
SHOWN ON PLANS, SEE PLUMBING FIXTURE
SCHEDULE, SHEET P001.
I.T.
F
2P101
BRANCH MANAGER102
VESTIBULE
101
OFFICE116
BREAK ROOM115
STORAGE114
REST113
REST
112
STORAGE111
ADMIN
109
JANITOR
117
VAULT110MDP108
HALL
107
OFFICE
106OFFICE
105
OFFICE104
LOBBY
103
D
D
C
C
B
BA
A
1 1
2 2
6 6
8 8
3 3
4 4
5 5
7 7
5.2 5.2
E
E
F
F
4"
RD-4
ORD-4
4"
1 2
3
10
9
8
7
7
4
6
4
3" VTR
HB-1
4"
4
1 1/2"
2"
3/4"
3/4"
HB-1
1 1/4"
3/4"1"
1 1/4"
IM-1WCO
WCO
4
4"
4
1 1/2"
S-1
3"
9
RD-3
6
14
13
13
INVERTELEVATION
= 95.5'
D
O
AC
1
RTU
2
RTU
1
3624 SQFT
D
D
C
C
B
BA
A
1 1
2 2
6 6
8 8
3 3
4 4
5 5
7 7
5.2 5.2
E
E
F
F
RD-4
ORD-4
11
12
3" VTR
3" VTR
11
12
RD-3
2 ENLARGED PLUMBING FLOOR PLAN
SCALE: 1/4" = 1'-0"
1 PLUMBING FLOOR PLAN
SCALE: 1/8" = 1'-0"
3 PLUMBING ROOF PLAN
SCALE: 1/8" = 1'-0"
ME
C
H
A
N
I
C
A
L
SC
H
E
D
U
L
E
S
,
DE
T
A
I
L
S
,
&
GE
N
E
R
A
L
N
O
T
E
S
M001
SH
E
E
T
T
I
T
L
E
:
SHEET NUMBER:
PR
O
J
E
C
T
:
SE
A
L
:
TH
I
S
D
R
A
W
I
N
G
I
S
C
L
A
S
S
I
F
I
E
D
A
S
PA
R
T
O
F
A
N
U
N
P
U
B
L
I
S
H
E
D
CO
L
L
E
C
T
I
O
N
O
F
V
I
S
U
A
L
A
R
T
.
UN
D
E
R
T
H
E
1
9
7
8
C
O
P
Y
R
I
G
H
T
AC
T
,
I
T
I
S
A
N
E
X
C
L
U
S
I
V
E
OR
I
G
I
N
A
L
W
O
R
K
O
F
AU
T
H
O
R
S
H
I
P
.
N
O
N
E
O
F
T
H
E
PIC
T
O
R
I
A
L
,
G
R
A
P
H
I
C
O
R
TE
C
H
N
I
C
A
L
C
H
A
R
T
S
O
R
DR
A
W
I
N
G
S
D
E
P
I
C
T
E
D
O
N
T
H
I
S
SH
E
E
T
M
A
Y
B
E
R
E
P
R
O
D
U
C
E
D
OR
T
R
A
N
S
M
I
T
T
E
D
I
N
A
N
Y
F
O
R
M
OR
B
Y
A
N
Y
M
E
A
N
S
W
I
T
H
O
U
T
T
H
E
EX
P
R
E
S
S
P
R
I
O
R
W
R
I
T
T
E
N
PE
R
M
I
S
S
I
O
N
O
F
T
H
E
A
R
C
H
I
T
E
C
T
.
TH
I
S
P
L
A
N
I
S
P
R
O
D
U
C
E
D
O
N
L
Y
FO
R
T
H
I
S
P
R
O
J
E
C
T
O
N
T
H
I
S
S
I
T
E
AN
D
M
A
Y
N
O
T
B
E
U
S
E
D
A
T
OT
H
E
R
L
O
C
A
T
I
O
N
S
.
RE
V
DA
T
E
DE
S
C
R
I
P
T
I
O
N
DO NOT SCALE DRAWING
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
4123 5 6
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
d
a
t
e
:
1
1
/
1
7
/
1
4
RE
X
B
U
R
G
,
I
D
PR
O
J
E
C
T
:
RE
X
B
U
R
G
B
R
A
N
C
H
CO
R
N
E
R
O
F
2
N
D
&
M
A
I
N
S
T
.
MO
U
N
T
A
I
N
A
M
E
R
I
C
A
C
R
E
D
I
T
U
N
I
O
N
em
a
a
r
c
h
i
t
e
c
t
s
│29
0
9
W
A
S
H
I
N
G
T
O
N
B
L
V
D
-
O
G
D
E
N
,
U
T
8
4
4
0
1
│PH
:
8
0
1
-
6
1
8
-
3
4
6
3
T
H
C
TITLE
SECTION
SHEET #
MECH ROOF PLAN
DETAIL #
SHEET #
1
EQUIPMENT CALLOUT
1
1
1
1
RTU
1
S
MECHANICAL GENERAL NOTES MECHANICAL LEGEND
91ºF Db SUMMER
HVAC DESIGN DATA
OUTSIDE DESIGN TEMPS.:61ºF Wb SUMMER
-10ºF Db WINTER
DESIGN ALTITUDE: 4900 FT.
INTERIOR DESIGN DATA
ALL
SUMMER WINTER
Db
75º
%HUMIDITY
50%72º40%
Db %HUMIDITY
NOTE:
THE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT OF THE WORK. DUE TO
THE SCALE OF THE DRAWINGS, OFFSET, FITTINGS, AND ACCESSORIES MAY NOT BE
INDICATED. WORK INDICATED, BUT HAVING DETAILS OMITTED, SHALL BE
COMPLETELY PROVIDED BY CONTRACTOR TO PERFORM FUNCTION INTENDED ATNO ADDITIONAL COST.
CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, PLUMBING,MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS TO AVOID
CONFLICT WITH OTHER TRADES. MINOR VARIATIONS IN LOCATION OF EQUIPMENT
SHALL BE MADE ON WRITTEN APPROVAL OF THE ENGINEER AT NO ADDITIONAL
COST.
NOTE:
MECHANICAL CONTRACTOR TO REVIEW ALL DRAWINGS
FOR CONFLICTS WITH STRUCTURE AND OTHER TRADES.
MECHANICAL CONTRACTOR TO RESOLVE ALL CONFLICTS
WITH ENGINEER PRIOR TO ORDERING, FABRICATING ORINSTALLING DUCTWORK.
NOTE:
1) SPACE ABOVE CEILING IS TO BE USED AS A RETURN AIRPLENUM. ALL MATERIALS TO BE PLENUM RATED.
2) ALL TERMINAL SUPPLY DUCT BRANCHES TO BEEQUIPPED WITH MANUAL BALANCING DAMPER.
3) FLEX DUCT (MAXIMUM 60" LONG) TYPICAL ON EACH
DIFFUSER EXCEPT IN EXPOSED APPLICATIONS.
4) PROVIDE TURNING VANES IN ALL RECTANGULAR
ELBOWS.
FL
O
O
R
&
R
O
O
F
ME
C
H
A
N
I
C
A
L
PL
A
N
M101
SH
E
E
T
T
I
T
L
E
:
SHEET NUMBER:
PR
O
J
E
C
T
:
SE
A
L
:
TH
I
S
D
R
A
W
I
N
G
I
S
C
L
A
S
S
I
F
I
E
D
A
S
PA
R
T
O
F
A
N
U
N
P
U
B
L
I
S
H
E
D
CO
L
L
E
C
T
I
O
N
O
F
V
I
S
U
A
L
A
R
T
.
UN
D
E
R
T
H
E
1
9
7
8
C
O
P
Y
R
I
G
H
T
AC
T
,
I
T
I
S
A
N
E
X
C
L
U
S
I
V
E
OR
I
G
I
N
A
L
W
O
R
K
O
F
AU
T
H
O
R
S
H
I
P
.
N
O
N
E
O
F
T
H
E
PIC
T
O
R
I
A
L
,
G
R
A
P
H
I
C
O
R
TE
C
H
N
I
C
A
L
C
H
A
R
T
S
O
R
DR
A
W
I
N
G
S
D
E
P
I
C
T
E
D
O
N
T
H
I
S
SH
E
E
T
M
A
Y
B
E
R
E
P
R
O
D
U
C
E
D
OR
T
R
A
N
S
M
I
T
T
E
D
I
N
A
N
Y
F
O
R
M
OR
B
Y
A
N
Y
M
E
A
N
S
W
I
T
H
O
U
T
T
H
E
EX
P
R
E
S
S
P
R
I
O
R
W
R
I
T
T
E
N
PE
R
M
I
S
S
I
O
N
O
F
T
H
E
A
R
C
H
I
T
E
C
T
.
TH
I
S
P
L
A
N
I
S
P
R
O
D
U
C
E
D
O
N
L
Y
FO
R
T
H
I
S
P
R
O
J
E
C
T
O
N
T
H
I
S
S
I
T
E
AN
D
M
A
Y
N
O
T
B
E
U
S
E
D
A
T
OT
H
E
R
L
O
C
A
T
I
O
N
S
.
RE
V
DA
T
E
DE
S
C
R
I
P
T
I
O
N
DO NOT SCALE DRAWING
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
DE
S
C
R
I
P
T
I
O
N
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
MM
-
D
D
-
Y
Y
4123 5 6
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
d
a
t
e
:
1
1
/
1
7
/
1
4
RE
X
B
U
R
G
,
I
D
PR
O
J
E
C
T
:
RE
X
B
U
R
G
B
R
A
N
C
H
CO
R
N
E
R
O
F
2
N
D
&
M
A
I
N
S
T
.
MO
U
N
T
A
I
N
A
M
E
R
I
C
A
C
R
E
D
I
T
U
N
I
O
N
em
a
a
r
c
h
i
t
e
c
t
s
│29
0
9
W
A
S
H
I
N
G
T
O
N
B
L
V
D
-
O
G
D
E
N
,
U
T
8
4
4
0
1
│PH
:
8
0
1
-
6
1
8
-
3
4
6
3
1
2
3
4
5
MANUAL BALANCING DAMPER (TYPICAL).
PIPE CONDENSATE FULL SIZE TO NEAREST ROOF DRAIN.
RUN REFRIGERANT PIPING FROM INDOOR UNIT TO
OUTSIDE UNIT. SIZE PER MANUFACTURER'S
RECOMMENDATIONS. INSTALL OUTDOOR UNIT ON ROOF
WITH MINIMUM 8" CURB. RUN CONDENSATE PUMP
DISCHARGE FULL SIZE TO SERVICE SINK IN JANITORS
ROOM.
INSTALL UNIT HEATER AS HIGH AS POSSIBLE.
THERMOSTAT LOCATION.
KEYED NOTES
NOTE:
1) SPACE ABOVE CEILING IS TO BE USED AS A RETURN AIR PLENUM. ALL MATERIALS TO BE PLENUMRATED.
2) ALL TERMINAL SUPPLY DUCT BRANCHES TO BE EQUIPPED WITH MANUAL BALANCING DAMPER.
3) FLEX DUCT (MAXIMUM 60" LONG) TYPICAL ON EACH DIFFUSER EXCEPT IN EXPOSED APPLICATIONS.
4) PROVIDE TURNING VANES IN ALL RECTANGULAR ELBOWS.