Loading...
HomeMy WebLinkAboutPLANS PLUMBING & MECHANICAL - 14-00529 - 18 N 2nd E - Mountain America Credit UnionPL U M B I N G SC H E D U L E S , DE T A I L S , & GE N E R A L N O T E S P001 SH E E T T I T L E : SHEET NUMBER: PR O J E C T : SE A L : TH I S D R A W I N G I S C L A S S I F I E D A S PA R T O F A N U N P U B L I S H E D CO L L E C T I O N O F V I S U A L A R T . UN D E R T H E 1 9 7 8 C O P Y R I G H T AC T , I T I S A N E X C L U S I V E OR I G I N A L W O R K O F AU T H O R S H I P . N O N E O F T H E PIC T O R I A L , G R A P H I C O R TE C H N I C A L C H A R T S O R DR A W I N G S D E P I C T E D O N T H I S SH E E T M A Y B E R E P R O D U C E D OR T R A N S M I T T E D I N A N Y F O R M OR B Y A N Y M E A N S W I T H O U T T H E EX P R E S S P R I O R W R I T T E N PE R M I S S I O N O F T H E A R C H I T E C T . TH I S P L A N I S P R O D U C E D O N L Y FO R T H I S P R O J E C T O N T H I S S I T E AN D M A Y N O T B E U S E D A T OT H E R L O C A T I O N S . RE V DA T E DE S C R I P T I O N DO NOT SCALE DRAWING DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y 4123 5 6 DE S C R I P T I O N IS S U E d a t e : 1 1 / 1 7 / 1 4 RE X B U R G , I D PR O J E C T : RE X B U R G B R A N C H CO R N E R O F 2 N D & M A I N S T . MO U N T A I N A M E R I C A C R E D I T U N I O N em a a r c h i t e c t s │29 0 9 W A S H I N G T O N B L V D - O G D E N , U T 8 4 4 0 1 │PH : 8 0 1 - 6 1 8 - 3 4 6 3 GENERAL PLUMBING NOTES 1. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE, OPERATIONAL PLUMBING SYSTEM FOR THE ENTIRE PROJECT AS SHOWN ON THESE DRAWINGS, INCLUDING ALL NECESSARY FEES AND PERMITS. 2. THE ENTIRE INSTALLATION SHALL CONFORM TO THE MOST RECENTLY ADOPTED REQUIREMENTS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL BUILDING CODE, AND ALL OTHER APPLICABLE CITY, COUNTY, AND STATE CODES AND REGULATIONS IN EFFECT AT THE DATE OF THE PERMITTING. 3. PRIOR TO FABRICATION AND INSTALLATION THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL PLUMBING PIPING, DUCTWORK, AND EQUIPMENT WITH PLUMBING PIPING, PLUMBING EQUIPMENT, ALL DUCTWORK, AND ALL OTHER TRADES INCLUDING BUT NOT LIMITED TO THE MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR, GENERAL CONTRACTOR, AND ANY CONTRACTOR HIRED DIRECTLY BY THE OWNER. WHERE CONFLICTS MAY OCCUR, THEY SHALL BE RESOLVED PRIOR TO INSTALLATION. 4. THE DRAWINGS SHOW THE GENERAL DESIGN, ARRANGEMENTS AND THE EXTENT OF THE SYSTEM. IT SHALL BE THE WORK OF THE CONTRACTOR TO MAKE SUCH SLIGHT ALTERATIONS AS MAY BE NECESSARY TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL IN ACCORDANCE WITH THE DESIGN INTENT. MAJOR DEVIATIONS SUCH AS CHANGES IN COMPONENT SIZES, WEIGHTS, QUANTITIES, OR MATERIAL REQUIRE PRIOR APPROVAL BY THE CONSULTING ENGINEER. 5. ALL PLUMBING INFORMATION IS NOT SHOWN ON THE PLUMBING DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INFORMATION ON ALL OTHER CONSTRUCTION DOCUMENTS INCLUDING ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. 6. THE WORKING DRAWINGS ARE DIAGRAMMATIC. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THEY DO NOT SHOW EVERY OFFSET, BEND OR ELBOW NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED. ALL LOCATIONS FOR PLUMBING EQUIPMENT AND PIPING SHALL BE CHECKED AND COORDINATED WITH THE ARCHITECTURAL, MECHANICAL, STRUCTURAL AND ELECTRICAL DRAWINGS. 7. EXACT ROUTING OF WASTE, GAS, AND WATER SERVICE IS DEPENDENT ON LOCAL SITE CONDITIONS AND MODIFICATIONS IN EQUIPMENT CONNECTIONS. EXACT LOCATION OF EQUIPMENT MAY VARY DEPENDING ON LOCAL CODE, HEALTH DEPARTMENT AND CITY REQUIREMENTS. 8. DETAILS: THE CONTRACTOR IS RESPONSIBLE TO REVIEW AND USE WHERE APPROPRIATE ALL OF THE PLUMBING DETAILS SHOWN ON THE DRAWINGS. DETAILS MAY OR MAY NOT BE CALLED OUT ON THE DRAWINGS WITH SYMBOLS OR KEYED NOTES. ANY CHANGES RESULTING FROM FAILURE TO INSTALL THE PLUMBING SYSTEM WITHOUT USING THE INCLUDED DETAILS IS THE RESPONSIBILITY OF THE CONTRACTOR. 9. THE DRAWINGS AND SPECIFICATIONS HAVE BEEN PREPARED TO SUPPLEMENT EACH OTHER AND THEY SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH THE ITEMS SHOWN ON ONE AND NOT THE OTHER BEING FURNISHED AND INSTALLED AS THOUGH SHOWN AND CALLED OUT IN BOTH. 10. PREPARE 6 COPIES OF SUBMITTALS IN AN INDEXED, LABELED FOLDER CONTAINING FULL PERFORMANCE, MATERIAL AND INSTALLATION INFORMATION ABOUT ALL EQUIPMENT, PIPING, COMPONENTS AND ACCESSORIES TO BE USED. 11. THE STRUCTURE SHOWN ON ALL DETAILS MAY OR MAY NOT PERTAIN TO A PORTION OR ANY PORTION OF THE BUILDING. COORDINATE MOUNTING REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 12. ANY PART OF THIS INSTALLATION THAT FAILS, IS UNFIT, OR BECOMES DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 13. ALL EQUIPMENT SHALL PROVIDE THE SCHEDULED PERFORMANCE AT THE SITE ALTITUDE. 14. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, VALVES, AND OTHER DEVICES AND ACCESSORIES REQUIRED FOR A COMPLETE, WORKABLE INSTALLATION. 15. ALL MOTORS REQUIRED SHALL BE BY THE DIVISION 15 CONTRACTOR. ALL MOTOR STARTING EQUIPMENT, IF NOT A PART OF THE EQUIPMENT, IS FURNISHED BY THE ELECTRICAL CONTRACTOR. 16. THE CONTRACTOR IS RESPONSIBLE FOR PLUMBING EQUIPMENT CHECK-IN, SAFEKEEPING, AND DAMAGE. 17. INVERTS SHOWN ON PLUMBING DRAWINGS MAY BE REFERENCED FROM THE FINISHED FLOOR ELEVATION. COORDINATE ALL INVERTS WITH CIVIL DRAWINGS PRIOR TO INSTALLATION. 18. PROVIDE WALL CLEANOUTS IN ALL VENTS FOR COMBINATION WASTE AND VENT SYSTEMS AS REQUIRED BY LOCAL AND NATIONAL CODES. 19. ALL VENT FITTINGS FOR WASTE SYSTEMS BELOW OVERFLOWS OF FIXTURES SHALL BE DRAINAGE TYPE. 20. CONTRACTOR TO COMPLY WITH THE LATEST ADOPTED IPC WHEN SIZING TRAP ARMS ON COMBINATION WASTE AND VENT SYSTEMS. THE DRAWINGS INDICATE THE WASTE LINE SIZE AND THE SIZE OF THE TRAP REQUIRED. 21. PROVIDE CLEANOUTS IN ACCORDANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. FLOOR CLEANOUTS SHALL BE LOCATED OUT OF TRAFFIC AREAS. 22. LOCATE ALL PLUMBING VENTS AT LEAST 3 FEET ABOVE OR 10 FEET AWAY FROM ALL OUTSIDE AIR INTAKES INTO THE BUILDING. 23. SEE "PLUMBING FIXTURE SCHEDULE" FOR FIXTURE MAKE AND TYPE, AND SIZE OF INDIVIDUAL WASTE, VENT, AND DOMESTIC WATER PIPING TO FIXTURES. 24. ALL PLUMBING EQUIPMENT SHALL BE LISTED AND LABELED BY AN APPROVED TESTING AGENCY. 25. EQUIPMENT AND INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION (NSF) STANDARDS, OR EQUIVALENT. 26. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING. 27. ALL PIPE SHALL BE SECURED BY DOUBLE NUTTING AT THE HANGER ROD ATTACHMENT TO THE STRUCTURE, AND AT THE PIPE HANGER. 28. PROVIDE WATER HAMMER ARRESTORS (SHOCK ABSORBERS) AT ALL PIPE LOCATIONS WHERE VALVE CLOSURES (SUCH AS FLUSH VALVES) MAY CAUSE WATER HAMMER OR RESULT IN EXCESSIVE PIPE VIBRATION OR MOVEMENT. 29. PROPERLY LUBRICATE ALL PIECES OF EQUIPMENT BEFORE TURNING THE SYSTEM OVER TO THE OWNER. 30. TWO OPERATING AND MAINTENANCE MANUALS SHALL BE PROVIDED IN HARD BACK LOOSE LEAF BINDERS. MANUALS SHALL CONTAIN PRODUCT CUT SHEETS AND OPERATING AND MAINTENANCE INSTRUCTIONS ON ALL EQUIPMENT, ACCESSORIES, FIXTURES, VALVES, ETC., PROVIDED FOR THE PROJECT. 31. UPON COMPLETION OF THE WORK, REMOVE ALL SURPLUS MATERIALS AND RUBBISH. MAKE ALL REQUIRED PATCHING AND REPAIRS OF OTHER TRADES' WORK DAMAGED BY THIS CONTRACTOR, AND LEAVE THE PREMISES IN A CLEAN, ORDERLY CONDITION. 32. THE CONTRACTOR SHALL OPERATE THE SYSTEM AND DEMONSTRATE ALL ASPECTS TO THE ENGINEER AND/OR OWNER, TO PROVE ITS OPERATION. 33. THE CONTRACTOR SHALL GUARANTEE THE PLUMBING SYSTEM FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. 34. THE CONTRACTOR SHALL, DURING CONSTRUCTION, MAINTAIN A SET OF AS-BUILT REDLINED RECORD DRAWINGS AT THE PROJECT SITE. ALL CHANGES IN LAYOUT, ROUTING, EQUIPMENT, COMPONENTS, AND ACCESSORIES SHALL BE RECORDED. THESE REDLINES SHALL BE GIVEN TO THE ARCHITECT/ENGINEER AFTER THE FINAL INSPECTION. SHUT OFF (BALL VALVE TYPE) PRESSURE REDUCING VALVE (GAS OR WATER) LIQUEFIED PETROLEUM GASLP PLUMBING LEGEND POINT OF CONNECTION KEYED NOTE CALLOUT POINT OF DEMOLITION FIXTURE CALLOUT SECTION CALLOUT TITLE SECTION SHEET # FLOOR DRAIN FLOOR SINK TEE ROOF DRAIN OVERFLOW ROOF DRAIN BOTTOM CONNECTION TOP CONNECTION CAP OR PLUG PIPE BREAK DIRECTION OF FLOW DIRECTION OF PIPE SLOPE CW HW POTABLE HOT WATER PIPE POTABLE COLD WATER PIPE SS SANITARY SEWER PIPE POTABLE HOT WATER RETURN PIPEHWR GW GW GREASE WASTE LINE ABOVE GRADE GREASE WASTE LINE V VTRVTR RD ORD RD ORD OVERFLOW ROOF DRAIN LINE ROOF DRAIN LINE VENT THROUGH THE ROOF VENT LINE SANITARY SEWER PIPE BELOW GRADESS RD G NATURAL GAS LINE ROOF DRAIN LINE BELOW GRADE FIRE SPRINKLER RISER HAMMER ARRESTOR FIRE DEPARTMENT CONNECTION HOSE BIBB WITH SHUT OFF TRAP PRIMER TWO WAY CLEAN OUT TO GRADE2-WAY COTG FCO CO WCO FLOOR CLEANOUT WALL CLEANOUT EXPOSED CLEANOUT COTG CLEANOUT TO GRADE FCO WCO CO COTG COTG 2-WAY PIPE RISE PIPE DROP ORD RD FD FS ENLARGED PLUMBING DETAIL CALLOUTDETAIL # SHEET # EQUIPMENT CALLOUT BACK FLOW PREVENTER PSI18.0 PSI25.0 PSI32.0 PSI23.0 PSI2 PSI7 75 PSI 41 0 0 GPM GPM GPM 41 BUILDING WATER SUPPLY CALCULATIONS TOTAL FIXTURE UNITS: ESTIMATED DEMAND: IRRIGATION DEMAND: HVAC DEMAND: TOTAL DEMAND: PRESSURE AVAILABLE AT STREET MAIN: PRESSURE LOSS DUE TO HEIGHT ( FT. x 0.434): PRESSURE LOSS THROUGH METER: PRESSURE LOSS THROUGH OTHER DEVICES:(i.e. Water Softener, Filters, Backflow Preventer, PRV) TOTAL PRESSURE LOSS (Add lines 2 thru 4): PRESSURE REQUIRED AT HIGHEST FIXTURE: PRESSURE AVAILABLE FOR FRICTION LOSS:(Subtract lines 5 & 6 from line 1) 1. 2. 3. 4. 5. 6. 7. HORIZONTAL PIPE LENGTH: VERTICAL PIPE LENGTH: EQUIVALENT FITTING LENGTH: TOTAL DEVELOPED LENGTH: FRICTION LOSS CALCULATION:(Line 7 / Line 11) x 100 DOMESTIC WATER SERVICE SIZE: WATER METER SIZE: BUILDING SEWER SIZE: 8. 9. 10. 11. 12. DE M A N D S PR E S S U R E L O S S E S FR I C T I O N L O S S SU M M A R Y WATER SUPPLY:WASTE:24 GPM 16 FT145 FT25 FT20 100 29 FT (/100 FT)12.4 1-1/2"DIA. DIA.1" DIA.4" TOTAL (CFH) = BTU/CUBIC FT. = 231123 SECTION SPECIFICATION TOTAL INPUTEQUIPMENTLOCATIONEQUIP. NO. TOTAL (BTUH) = GAS PRESSURE IN BUILDING PIPE SIZE AT METER QTY.MBH INPUT NATURAL GAS REQUIREMENTS RTU-1 1 1 ROOF ROOF ROOFTOP UNIT 180,000 RTU-2 ROOFTOP UNIT DESIGN LENGTH 90' 4 OZ 1 1/4" 245,000 1000 245 65,000 180,000 65,000 RECIRCULATION PUMP WASTE PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE WATER COLD WATER HOT VENT ACCESSORIES AND REMARKSTRAP FLOOR MOUNTED, FLUSH VALVE2"4"---1"WATER CLOSET (ADA COMPLIANT)WC-2 INT. 1-1/2"S-1 SINK - SINGLE COMPARTMENT 1/2"1/2"1-1/2"1-1/2"COUNTER MOUNTED SINGLE COMPARTMENT HB-1 3"SS-1 SERVICE SINK 1/2"1/2"3"2"FLOOR MOUNTED WITH DEEP SEAL TRAP 2"FD-2 FLOOR DRAIN ------2"2"WITH DEEP SEAL TRAP FREEZELESS---------3/4"HOSE BIBB (ENCASED)--- 3"FD-3 FLOOR DRAIN ------3"2"WITH DEEP SEAL TRAP 1-1/4"L-1 LAVATORY (ADA COMPLIANT)1/2"1/2"1-1/4"1-1/4"COUNTER MOUNTED, ADA COMPLIANT PROVIDE WATTS USG-B THERMOSTATIC TEMPERING VALVE UNDER COUNTER TO EACH LAV. ELECTRIC WATER COOLER, WALL HUNG, 8 GPH, ADA WHEELCHAIR1-1/2"1-1/2"---1/2"WATER COOLER (ADA WHEELCHAIR)DF-1 1-1/2" RD-4 ROOF DRAIN 4"------------ PROVIDE WITH 4" DAMORD-4 OVERFLOW ROOF DRAIN 4"------------ SPECIFICATION SECTION 224000, 221119, 221319, 221423 ---TS ------------JAY R SMITH QUAD CLOSE TRAP SEALTRAP SEAL ---WATER HAMMER ARRESTOR 3/4'---------12-32 FIXTURE UNITSHA-3/4 ---------1/2"ICE MAKER CONNECTIONIM-1 --- ELECTRIC WATER HEATER SCHEDULE (GAL.) CAPACITY STORAGE EWH-1 SYMBOL BRADFORD WHITE LD-WH20L3-1 STORAGE TYPE (LBS.) WEIGHT 59 OPERATINGINPUTRECOVERY CAPACITY 19 6 RATE (GPH) VOLTS/Ø/HZ. 1.5 (KW) 120/1/60 WATER 40° - 140° IN/OUT TEMP. 22"Ø x 47.5" SIZE OVERALL 2 GALLON EXPANSION TANK, WALL HANGING KIT MANUFACTURER AND MODEL NO. ACCESSORIES AND REMARKS SPECIFICATION SECTION 223300 ------------3"OVERFLOW ROOF DRAINORD-3 PROVIDE WITH 4" DAM ------------3"ROOF DRAINRD-3 GW 3 RD RD ORD 1 HB-1 WHID 1 1 A301 2 SCALE: 1/4" = 1' - 0" A301 2 BP BALANCING VALVES TEMPERING VALVE MAY EXTEND AS A WASTE OR VENT LINE FINISHED FLOOR 1/8" C.I. BEND REFERENCED ON DRAWING AS "WCO" BALANCE OF PIPING SAME AS CLEANOUT TOGRADE PLUGGED TEE WITH CLEANOUT CHROME WALL COVER AND SCREW WALL FINISHED GRADE 18"x18"x6" THICK CONCRETE PAD C.I. PIPE (SIZE AS SHOWN ONDRAWINGS) 4" C.I. PIPE CEMENT PATCH 4" C.I. CLEANOUT PLUG C.I. COVER AND FRAME 6" MIN. VARIES 1'-0"1'-0" 6" LAYERS OF SAND, COMPACTABLE SOIL, OR APPROVED GRAVEL PLACED AND COMPACTED 95% MIN. DRY DENSITY AASHTO T-180 CONCRETE SLAB FINISHED FLOOR CONCRETE (TYP.) USE CAULKED OUTLET TYPE CONNECTION. DEEP SEAL P-TRAP WATERPROOF MEMBRANE FLASHED INTO CLAMPING COLLAR. ADJUSTABLE HEAD SET FLUSH WITH FINISHED FLOOR SLOPE SLOPE HANGER ROD DOUBLE NUT CLEVIS HANGER TO ROD PIPE INSULATION RIGID INSULATION AT SUPPORT 22 GAUGE SHEET METAL INSULATION SHIELD - 12" LONG CARRIER PIPE CLEVIS HANGER 12 " 10 " 12" MIN. ROOFING ROOF DECKVENT FLASHING STAINLESS STEEL CLAMP SEALANT ACCESS FRAME AND COVER TOP OF COVER SHALL BEFLUSH WITH TOP OF FLOOR COUNTERSUNK SCREW CAST IRON 1/8 BEND 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE WASTE PIPING BALANCE OF PIPING SAME AS CLEANOUT TO GRADE FINISHED FLOOR BRASS CLEANOUT PLUG AND FERRULE 1" REDUCED PRESSURE BACKFLOW PREVENTOR. PROVIDE INLET AND OUTLET SHUT- OFF VALVES AND 4 TEST COCKS. (MAY BE SUBSTITUTED WITH DOUBLE CHECK ASSEMBLY IF APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION) TO POTABLE WATERSYSTEM GLOBE VALVE PRESSURE GAGE (TYP) UNION (TYP) BALL VALVE (TYP) PRESSURE REDUCING VALVE TO HANDLE --- GPM @ 65 PSI DISCHARGE PRESSURE STRAINER WITH BLOWDOWN INCOMING WATER SERVICE SLEEVE CONCRETE FLOOR 12" MINIMUM ABOVE FLOOR R VACUUM RELIEF VALVE EXPANSION TANK BALL VALVE COLD WATER SUPPLY P&T RELIEF VALVE DRAIN VALVE W/THREADED HOSE CONNECTION DIELECTRIC UNION (TYPICAL) HOT WATER THERMOMETER R RUN DISCHARGE LINE TOSERVICE SINK SUPPORT WITH FACTORY WALL HANGER BRACE LINE TO WALL ANCHOR WATER HEATER TO WALL USE 1" X 18 GA. STRAP WITH #10 X 2 1/2" WOOD SCREWS. TYPICAL OF TWO PLACES. 1 WALL CLEANOUT SCALE: 1' = 1'-0" 2 CLEANOUT TO GRADE SCALE: 1' = 1'-0" 6 PIPE UNDER SLAB SCALE: 1' = 1'-0" 5 FLOOR DRAIN SCALE: 1' = 1'-0" 3 INSULATED PIPE HANGER SCALE: 1' = 1'-0" 4 VENT THRU ROOF (FLAT) SCALE: 1' = 1'-0" 7 FLOOR CLEANOUT SCALE: 1' = 1'-0"8 WATER PRESSURE REDUCING VALVE STATION SCALE: 1' = 1'-0"9 ELECTRIC WATER HEATER WALL HUNG W/ BRACKET SCALE: 1' = 1'-0" 4141 FL O O R & R O O F PL U M B I N G P L A N P101 SH E E T T I T L E : SHEET NUMBER: PR O J E C T : SE A L : TH I S D R A W I N G I S C L A S S I F I E D A S PA R T O F A N U N P U B L I S H E D CO L L E C T I O N O F V I S U A L A R T . UN D E R T H E 1 9 7 8 C O P Y R I G H T AC T , I T I S A N E X C L U S I V E OR I G I N A L W O R K O F AU T H O R S H I P . N O N E O F T H E PIC T O R I A L , G R A P H I C O R TE C H N I C A L C H A R T S O R DR A W I N G S D E P I C T E D O N T H I S SH E E T M A Y B E R E P R O D U C E D OR T R A N S M I T T E D I N A N Y F O R M OR B Y A N Y M E A N S W I T H O U T T H E EX P R E S S P R I O R W R I T T E N PE R M I S S I O N O F T H E A R C H I T E C T . TH I S P L A N I S P R O D U C E D O N L Y FO R T H I S P R O J E C T O N T H I S S I T E AN D M A Y N O T B E U S E D A T OT H E R L O C A T I O N S . RE V DA T E DE S C R I P T I O N DO NOT SCALE DRAWING DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y 4123 5 6 DE S C R I P T I O N IS S U E d a t e : 1 1 / 1 7 / 1 4 RE X B U R G , I D PR O J E C T : RE X B U R G B R A N C H CO R N E R O F 2 N D & M A I N S T . MO U N T A I N A M E R I C A C R E D I T U N I O N em a a r c h i t e c t s │29 0 9 W A S H I N G T O N B L V D - O G D E N , U T 8 4 4 0 1 │PH : 8 0 1 - 6 1 8 - 3 4 6 3 REST113 REST112ADMIN 109 JANITOR 117 FD-2 TS FD-2 TS 55 3" VTR 5 3/4" 1 1/2" 1 1/2" 2" 3/4" 3/4"3/4" 2"1/2" 3/4" 2" 2" 4" 2" HA-3/4 WCO 5 5 4" WCO L-1 WC-2 WC-2L-1 DF-1 EWH-1 SS-1 4" 13 13TS FD-3 BP FOR CONTINUATION OF WATER SERVICE PIPING SEE SITE PLAN. FOR CONTINUATION OF WASTE LINE SEE SITE PLAN. FOR CONTINUATION OF GAS LINE SEE SITE PLAN. FOR CONTINUATION OF PIPING SEE PLUMBING ENLARGEMENTS, DETAIL 2 SHEET P101. FOR CONTINUATION OF PIPING SEE PLUMBING FLOOR PLAN, DETAIL 1 SHEET P101. FOR CONTINUATION OF ROOF DRAIN LINES SEE PLUMBING ROOF PLAN, DETAIL 3 SHEET P101. FOR CONTINUATION OF GAS PIPING SEE PLUMBING ROOF PLAN, DETAIL 3 SHEET P101. GAS METER SIZE FOR 245 CFH AT 4 OZ. METER AND YARD LINE BY GAS COMPANY. OVERFLOW ROOF DRAIN NOZZLE 12" ABOVE FINSH GRADE. FOR CONTINUATION OF ROOF DRAIN LINE SEE CIVIL PLAN. PENETRATE SIDE OF UNIT AT KNOCKOUT WITH GAS PIPE, PROVIDE AND INSTALL A GAS SHUT-OFF VALVE AND DIRT LEG AS CLOSE TO THE UNIT INLET AS POSSIBLE ON OUTSIDE OF CABINET. PIPE CONDENSATE FULL SIZE TO NEAREST ROOF DRAIN. RUN PIPING ABOVE CEILING RUN PIPING BELOW FLOOR SLEEVE WATER PIPING BELOW FLOOR. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 KEYED NOTES NOTE: FOR BRANCH SIZES TO INDIVIDUAL FIXTURES NOT SHOWN ON PLANS, SEE PLUMBING FIXTURE SCHEDULE, SHEET P001. I.T. F 2P101 BRANCH MANAGER102 VESTIBULE 101 OFFICE116 BREAK ROOM115 STORAGE114 REST113 REST 112 STORAGE111 ADMIN 109 JANITOR 117 VAULT110MDP108 HALL 107 OFFICE 106OFFICE 105 OFFICE104 LOBBY 103 D D C C B BA A 1 1 2 2 6 6 8 8 3 3 4 4 5 5 7 7 5.2 5.2 E E F F 4" RD-4 ORD-4 4" 1 2 3 10 9 8 7 7 4 6 4 3" VTR HB-1 4" 4 1 1/2" 2" 3/4" 3/4" HB-1 1 1/4" 3/4"1" 1 1/4" IM-1WCO WCO 4 4" 4 1 1/2" S-1 3" 9 RD-3 6 14 13 13 INVERTELEVATION = 95.5' D O AC 1 RTU 2 RTU 1 3624 SQFT D D C C B BA A 1 1 2 2 6 6 8 8 3 3 4 4 5 5 7 7 5.2 5.2 E E F F RD-4 ORD-4 11 12 3" VTR 3" VTR 11 12 RD-3 2 ENLARGED PLUMBING FLOOR PLAN SCALE: 1/4" = 1'-0" 1 PLUMBING FLOOR PLAN SCALE: 1/8" = 1'-0" 3 PLUMBING ROOF PLAN SCALE: 1/8" = 1'-0" ME C H A N I C A L SC H E D U L E S , DE T A I L S , & GE N E R A L N O T E S M001 SH E E T T I T L E : SHEET NUMBER: PR O J E C T : SE A L : TH I S D R A W I N G I S C L A S S I F I E D A S PA R T O F A N U N P U B L I S H E D CO L L E C T I O N O F V I S U A L A R T . UN D E R T H E 1 9 7 8 C O P Y R I G H T AC T , I T I S A N E X C L U S I V E OR I G I N A L W O R K O F AU T H O R S H I P . N O N E O F T H E PIC T O R I A L , G R A P H I C O R TE C H N I C A L C H A R T S O R DR A W I N G S D E P I C T E D O N T H I S SH E E T M A Y B E R E P R O D U C E D OR T R A N S M I T T E D I N A N Y F O R M OR B Y A N Y M E A N S W I T H O U T T H E EX P R E S S P R I O R W R I T T E N PE R M I S S I O N O F T H E A R C H I T E C T . TH I S P L A N I S P R O D U C E D O N L Y FO R T H I S P R O J E C T O N T H I S S I T E AN D M A Y N O T B E U S E D A T OT H E R L O C A T I O N S . RE V DA T E DE S C R I P T I O N DO NOT SCALE DRAWING DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y 4123 5 6 DE S C R I P T I O N IS S U E d a t e : 1 1 / 1 7 / 1 4 RE X B U R G , I D PR O J E C T : RE X B U R G B R A N C H CO R N E R O F 2 N D & M A I N S T . MO U N T A I N A M E R I C A C R E D I T U N I O N em a a r c h i t e c t s │29 0 9 W A S H I N G T O N B L V D - O G D E N , U T 8 4 4 0 1 │PH : 8 0 1 - 6 1 8 - 3 4 6 3 T H C TITLE SECTION SHEET # MECH ROOF PLAN DETAIL # SHEET # 1 EQUIPMENT CALLOUT 1 1 1 1 RTU 1 S MECHANICAL GENERAL NOTES MECHANICAL LEGEND 91ºF Db SUMMER HVAC DESIGN DATA OUTSIDE DESIGN TEMPS.:61ºF Wb SUMMER -10ºF Db WINTER DESIGN ALTITUDE: 4900 FT. INTERIOR DESIGN DATA ALL SUMMER WINTER Db 75º %HUMIDITY 50%72º40% Db %HUMIDITY NOTE: THE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT OF THE WORK. DUE TO THE SCALE OF THE DRAWINGS, OFFSET, FITTINGS, AND ACCESSORIES MAY NOT BE INDICATED. WORK INDICATED, BUT HAVING DETAILS OMITTED, SHALL BE COMPLETELY PROVIDED BY CONTRACTOR TO PERFORM FUNCTION INTENDED ATNO ADDITIONAL COST. CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, PLUMBING,MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS TO AVOID CONFLICT WITH OTHER TRADES. MINOR VARIATIONS IN LOCATION OF EQUIPMENT SHALL BE MADE ON WRITTEN APPROVAL OF THE ENGINEER AT NO ADDITIONAL COST. NOTE: MECHANICAL CONTRACTOR TO REVIEW ALL DRAWINGS FOR CONFLICTS WITH STRUCTURE AND OTHER TRADES. MECHANICAL CONTRACTOR TO RESOLVE ALL CONFLICTS WITH ENGINEER PRIOR TO ORDERING, FABRICATING ORINSTALLING DUCTWORK. NOTE: 1) SPACE ABOVE CEILING IS TO BE USED AS A RETURN AIRPLENUM. ALL MATERIALS TO BE PLENUM RATED. 2) ALL TERMINAL SUPPLY DUCT BRANCHES TO BEEQUIPPED WITH MANUAL BALANCING DAMPER. 3) FLEX DUCT (MAXIMUM 60" LONG) TYPICAL ON EACH DIFFUSER EXCEPT IN EXPOSED APPLICATIONS. 4) PROVIDE TURNING VANES IN ALL RECTANGULAR ELBOWS. FL O O R & R O O F ME C H A N I C A L PL A N M101 SH E E T T I T L E : SHEET NUMBER: PR O J E C T : SE A L : TH I S D R A W I N G I S C L A S S I F I E D A S PA R T O F A N U N P U B L I S H E D CO L L E C T I O N O F V I S U A L A R T . UN D E R T H E 1 9 7 8 C O P Y R I G H T AC T , I T I S A N E X C L U S I V E OR I G I N A L W O R K O F AU T H O R S H I P . N O N E O F T H E PIC T O R I A L , G R A P H I C O R TE C H N I C A L C H A R T S O R DR A W I N G S D E P I C T E D O N T H I S SH E E T M A Y B E R E P R O D U C E D OR T R A N S M I T T E D I N A N Y F O R M OR B Y A N Y M E A N S W I T H O U T T H E EX P R E S S P R I O R W R I T T E N PE R M I S S I O N O F T H E A R C H I T E C T . TH I S P L A N I S P R O D U C E D O N L Y FO R T H I S P R O J E C T O N T H I S S I T E AN D M A Y N O T B E U S E D A T OT H E R L O C A T I O N S . RE V DA T E DE S C R I P T I O N DO NOT SCALE DRAWING DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y 4123 5 6 DE S C R I P T I O N IS S U E d a t e : 1 1 / 1 7 / 1 4 RE X B U R G , I D PR O J E C T : RE X B U R G B R A N C H CO R N E R O F 2 N D & M A I N S T . MO U N T A I N A M E R I C A C R E D I T U N I O N em a a r c h i t e c t s │29 0 9 W A S H I N G T O N B L V D - O G D E N , U T 8 4 4 0 1 │PH : 8 0 1 - 6 1 8 - 3 4 6 3 1 2 3 4 5 MANUAL BALANCING DAMPER (TYPICAL). PIPE CONDENSATE FULL SIZE TO NEAREST ROOF DRAIN. RUN REFRIGERANT PIPING FROM INDOOR UNIT TO OUTSIDE UNIT. SIZE PER MANUFACTURER'S RECOMMENDATIONS. INSTALL OUTDOOR UNIT ON ROOF WITH MINIMUM 8" CURB. RUN CONDENSATE PUMP DISCHARGE FULL SIZE TO SERVICE SINK IN JANITORS ROOM. INSTALL UNIT HEATER AS HIGH AS POSSIBLE. THERMOSTAT LOCATION. KEYED NOTES NOTE: 1) SPACE ABOVE CEILING IS TO BE USED AS A RETURN AIR PLENUM. ALL MATERIALS TO BE PLENUMRATED. 2) ALL TERMINAL SUPPLY DUCT BRANCHES TO BE EQUIPPED WITH MANUAL BALANCING DAMPER. 3) FLEX DUCT (MAXIMUM 60" LONG) TYPICAL ON EACH DIFFUSER EXCEPT IN EXPOSED APPLICATIONS. 4) PROVIDE TURNING VANES IN ALL RECTANGULAR ELBOWS.