Loading...
HomeMy WebLinkAboutCOMCHECK - 19-00364 - East Idaho Credit Union - New BuildingU COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: 20151ECC East Idaho Credit Union New Construction Construction Site: Owner/Agent: Designer/Contractor: 310 North 2nd East Steve Peterson Rexburg, ID 83440 Case, Lowe & Hart, Inc Floor Area 2484 Wasshington Blvd., SAte. 510 Additional Efficiency Package(s) Ogden, UT 84401 (ft2) 801-399-5821 stevep@clhae.com Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B X C) 1 -Credit Union (Office) 2388 0.74 1762 Total Allowed Watts = 1762 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1 -Credit Union (Office) LED 1: T-1: Liner Tube: LED Other Fixture Unit 125W: 1 2 185 370 LED 2: T-2 & 2E: LED Lay -in: LED Panel 38W: 1 24 38 912 LED 3: T-3: LED Down Light: LED PAR 12W: 1 2 13 25 LED 4: T-4 & 4E: LED Down Light LED PAR 20W: 1 9 35 312 LED 5: T-5: LED Strip: LED Other Fixture Unit 36W: 1 4 35 139 Total Proposed Watts = 1758 Interior Lighting PASSES: Design 0.2% better than code 'nterior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. ff' �N samd MK-.m,.nn, 1",.:, ""' c=Gu, Lcwc8Ha4lnc eu,¢mai=MNM�dhae.om, r -US Ke Let.; 1 s Name Title Signature Date Project Title: East Idaho Credit Union Report date: 06/03/19 Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Ana lysis\COM check\U ntitl ed East Page 1 of 8 Idaho CU Rexburg.cck eCOMcheck Software Version 4.1.1.0 ls(i Exterior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Exterior Lighting Zone Construction Site: 310 North 2nd East Rexburg, ID 83440 Allowed Exterior Lighting Power A Area/Surface Category 2015 IECC East Idaho Credit Union New Construction 4 (High activity metropolitan commercial district) Owner/Agent: Designer/Contractor: Steve Peterson Case, Lowe & Hart, Inc 2484 Wasshington Blvd., SAte. 510 Ogden, UT 84401 801-399-5821 stevep@clhae.com B C D E Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) ATM/Night depository location (c) 1 machines 90 No 270 Drive -up windows/doors 2 windows 400 No 800 Entry canopy 40 ft2 0.4 Yes 16 Driveway 90 ft2 0.13 Yes 12 Total Tradable Watts (a) = 3089 Total Allowed Watts = 4207 Total Allowed Supplemental Watts (b) = 1300 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 1300 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces. (c) ATM/Night depository sites have a base allowance of 180 W per site. Proposed Exterior Lighting Power A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast ATM/Night depository location (1 machines): Non -tradable Wattage LED 2: T-7: Canopy LED: LED Other Fixture Unit 80W: Drive -up windows/doors (2 windows or doors): Non -tradable Wattage LED 1: T-7: Canopy LED: LED Other Fixture Unit 80W: Entry canopy (40 ft2): Tradable Wattage LED 3: T-4: LED Down Light: LED PAR 20W: Main entry (6 ft of door width): Tradable Wattage Other door (not main entry) (3 ft of door width): Tradable Wattage Illuminated area of facade wall or surface (42 0 ft2): Non -tradable Wattage Walkway < 10 feet wide (165 ft of walkway length): Tradable Watta9e Parking area (20430 ft2): Tradable Wattage Driveway (90 ft2): Tradable Wattage B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 2 86 172 4 86 344 2 35 69 Project Title: East Idaho Credit Union Report date: 06/03/19 Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitledEast Page 2 of 8 Idaho CU Rexburg.cck A Fixture ID : Description / Lamp/ Wattage Per Lamp / Ballast B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. LED 5: T-11: LED Pole light: LED Roadway -Parking Unit 106W: 1 11 102 1122 LED 6: T-12 & 12E: Bollard LED: LED Other Fixture Unit 40W: 1 10 39 390 LED 4: T-8: LED Wall Pack: LED Other Fixture Unit 60W: 1 12 69 828 Total Tradable Proposed Watts = 2409 Exterior Lighting PASSES: Design 45% be Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Digily talsignetl by Kevin J. Lexis Kevin .�. Lewis ��' _<� Drr:�acennaLe.n,.e=cue,Lo..�avlrcxK,ee.enwx=l�n,u�dne.�m,=us Date:2019.06.03 19:1491-06'00' Name -Title Signature Date Project Title: East Idaho Credit Union Report date: 06/03/19 Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitledEast Page 3 of 8 Idaho CU Rexburg.cck eCOMcheck Software Version 4.1.1.0 �(J Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. # I Plan Review Ell C103.2 Plans, specifications, and/or [PR4]1 calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. C103.2 Plans, specifications, and/or [PR8]1 calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. C406 Plans, specifications, and/or 1[PR9]1 calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Additional Comments/Assumptions: ❑Complies ❑Does Not Comments/Assumption s Requirement will be met. ❑Not Observable Location on plans/spec: See plans and this document ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not ❑Not Observable Location on plans/spec: See plans and this document ❑Not Applicable ❑Complies Requirement will be met. []Does Not ❑Not Observable Location on plans/spec: See Documents and these calculations ❑Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: East Idaho Credit Union Report date: 06/03/19 Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitledEast Page 4 of 8 Idaho CU Rexburg.cck Section Location on plans/spec: See lighting plans -� - # Rough -In Electrical Inspection Complies? Comments/Assumptions & Req.ID ❑Not Observable ❑Not Observable C405.2.1 Lighting controls installed to uniformly [-]CompliesRequirement will be met. [EL15]1 reduce the lighting load by at least []Does Not allowed for special functions per the 50%. Location on plans/spec: Manual dimmers in required spaces ❑Not Observable ❑Not Applicable ❑Not Observable on lighting plans ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met. [EL18]1 required spaces. ❑Does Not lighting installed. Controls will be ❑Does Not ❑Not Observable Location on plans/spec: See restrooms daylight controlled, set based on ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3manual controls readily accessible and ❑Not Observable Location on plans/spec: See lighting plans [EL23]2 visible to occupants. J ❑Not Observable ❑Not Applicable C405.2.2. Automatic controls to shut off all 1 building lighting installed in all [EL22]2 buildings. C405.2.3 Daylight zones provided with [EL16]2 individual controls that control the lights independent of general area lighting. C405.2.3, C405.2.3. 1, C405.2.3. 2 I[EL20]1 C405.2.3, C405.2.3. 1 C405.2.3. 3 [EL21]1 C405.2.4 [EL4]1 C405.2.4 [EL8]1 C405.2.5 [EL251"1 C405.3 [EL6]1 Primary sidelighted areas are equipped with required lighting controls. ❑Complies Exception: Lighting controlled by occupancy sensors ❑Does Not ❑Not Observable Location on plans/spec: See lighting plans ❑Not Applicable specific uses installed per approved ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Observable Location on plans/spec: See lighting plans ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not allowed for special functions per the ❑Not Observable Location on plans/spec: See lighting plans ❑Not Applicable ❑Not Observable Enclosed spaces with daylight area ❑Complies Requirement will be met. under skylights and rooftop monitors ❑Does Not are equipped with required lighting ❑Not Observable Location on plans/spec: See lighting plans controls. ❑Not Applicable Separate lighting control devices for ❑Complies Requirement will be met. specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable Location on plans/spec: See lighting plans ❑Not Applicable Additional interior lighting power ❑Complies Requirement will be met. allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable Location on plans/spec: See lighting plans automatically controlled and separated from general lighting. ❑Not Applicable Automatic lighting controls for exterior ❑Complies Requirement will be met. lighting installed. Controls will be ❑Does Not daylight controlled, set based on ❑Not Observable Location on plans/spec: See exterior lighting control detail business operation time -of -day, or reduce connected lighting > 30%. ❑Not Applicable Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. face. ❑Does Not ❑Not Observable Location on plans/spec: See Igiht fixture schedule ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: East Idaho Credit Union Report date: 06103/19 Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Ana lysis\COMcheck\UntitledEast Page 5 of 8 Idaho CU Rexburg.cck Section Interior installed lamp and fixture � # Final Inspection Complies? & RegJD C303.3, Furnished O&M instructions for []Complies C408.2.5. systems and equipment to the []Does Not 2 [FI1713 building owner or designated representative. ❑Not Observable ❑Not Applicable Comments/Assumptions Requirement will be met. C405A.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [17I1831 lighting power is consistent with what ❑Does Not is shown on the approved lighting ❑Not Observable plans, demonstrating proposed watts ❑Not Applicable are less than or equal to allowed watts. C405.5.1 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved ❑Does Not lighting plans, demonstrating [-]Not Observable proposed watts are less than or equal ❑Not Applicable to allowed watts. C408.2.5. Furnished as -built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days ❑Does Not [FI1613 of system acceptance. ❑Not Observable ❑Not Applicable 'C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [FI3311 ensure proper calibration, adjustment, ❑Does Not programming, and operation.❑Not Observable Location on plans/spec: See Igiht fixture schedule ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: East Idaho Credit Union Report date: 06/03/19 Data filename: F:\Projects\19110 East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitleclEast Page 7 of 8 Idaho CU Rexburg.cck