HomeMy WebLinkAboutCOMCHECK - 19-00364 - East Idaho Credit Union - New BuildingU
COMcheck Software Version 4.1.1.0
Interior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
20151ECC
East Idaho Credit Union
New Construction
Construction Site: Owner/Agent:
Designer/Contractor:
310 North 2nd East
Steve Peterson
Rexburg, ID 83440
Case, Lowe & Hart, Inc
Floor Area
2484 Wasshington Blvd., SAte. 510
Additional Efficiency Package(s)
Ogden, UT 84401
(ft2)
801-399-5821
stevep@clhae.com
Reduced interior lighting power. Requirements are implicitly enforced within interior
lighting allowance calculations.
Allowed Interior Lighting Power
A
B
C
D
Area Category
Floor Area
Allowed
Allowed Watts
(ft2)
Watts / ft2
(B X C)
1 -Credit Union (Office)
2388
0.74
1762
Total Allowed Watts =
1762
Proposed Interior Lighting Power
A
B
C
D
E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
Lamps/
# of
Fixture
(C X D)
Fixture
Fixtures
Watt.
1 -Credit Union (Office)
LED 1: T-1: Liner Tube: LED Other Fixture Unit 125W:
1
2
185
370
LED 2: T-2 & 2E: LED Lay -in: LED Panel 38W:
1
24
38
912
LED 3: T-3: LED Down Light: LED PAR 12W:
1
2
13
25
LED 4: T-4 & 4E: LED Down Light LED PAR 20W:
1
9
35
312
LED 5: T-5: LED Strip: LED Other Fixture Unit 36W:
1
4
35
139
Total Proposed Watts = 1758
Interior Lighting PASSES: Design 0.2% better than code
'nterior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
ff' �N samd MK-.m,.nn,
1",.:, ""' c=Gu, Lcwc8Ha4lnc eu,¢mai=MNM�dhae.om, r -US
Ke Let.; 1 s
Name Title Signature Date
Project Title: East Idaho Credit Union Report date: 06/03/19
Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Ana lysis\COM check\U ntitl ed East Page 1 of 8
Idaho CU Rexburg.cck
eCOMcheck Software Version 4.1.1.0
ls(i Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
310 North 2nd East
Rexburg, ID 83440
Allowed Exterior Lighting Power
A
Area/Surface Category
2015 IECC
East Idaho Credit Union
New Construction
4 (High activity metropolitan commercial district)
Owner/Agent: Designer/Contractor:
Steve Peterson
Case, Lowe & Hart, Inc
2484 Wasshington Blvd., SAte. 510
Ogden, UT 84401
801-399-5821
stevep@clhae.com
B C D E
Quantity Allowed Tradable Allowed Watts
Watts/Unit Wattage (B X C)
ATM/Night depository location (c)
1 machines 90 No
270
Drive -up windows/doors
2 windows 400 No
800
Entry canopy
40 ft2 0.4 Yes
16
Driveway
90 ft2 0.13 Yes
12
Total Tradable Watts (a) =
3089
Total Allowed Watts =
4207
Total Allowed Supplemental Watts (b) =
1300
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 1300 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces.
(c) ATM/Night depository sites have a base allowance of 180 W per site.
Proposed Exterior Lighting Power
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
ATM/Night depository location (1 machines): Non -tradable Wattage
LED 2: T-7: Canopy LED: LED Other Fixture Unit 80W:
Drive -up windows/doors (2 windows or doors): Non -tradable Wattage
LED 1: T-7: Canopy LED: LED Other Fixture Unit 80W:
Entry canopy (40 ft2): Tradable Wattage
LED 3: T-4: LED Down Light: LED PAR 20W:
Main entry (6 ft of door width): Tradable Wattage
Other door (not main entry) (3 ft of door width): Tradable Wattage
Illuminated area of facade wall or surface (42 0 ft2): Non -tradable Wattage
Walkway < 10 feet wide (165 ft of walkway length): Tradable Watta9e
Parking area (20430 ft2): Tradable Wattage
Driveway (90 ft2): Tradable Wattage
B C D E
Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
2 86
172
4 86
344
2 35
69
Project Title: East Idaho Credit Union Report date: 06/03/19
Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitledEast Page 2 of 8
Idaho CU Rexburg.cck
A
Fixture ID : Description / Lamp/ Wattage Per Lamp / Ballast
B C D E
Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
LED 5: T-11: LED Pole light: LED Roadway -Parking Unit 106W: 1 11 102 1122
LED 6: T-12 & 12E: Bollard LED: LED Other Fixture Unit 40W: 1 10 39 390
LED 4: T-8: LED Wall Pack: LED Other Fixture Unit 60W: 1 12 69 828
Total Tradable Proposed Watts = 2409
Exterior Lighting PASSES: Design 45% be
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Digily talsignetl by Kevin J. Lexis
Kevin .�. Lewis ��' _<� Drr:�acennaLe.n,.e=cue,Lo..�avlrcxK,ee.enwx=l�n,u�dne.�m,=us
Date:2019.06.03 19:1491-06'00'
Name -Title Signature Date
Project Title: East Idaho Credit Union Report date: 06/03/19
Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitledEast Page 3 of 8
Idaho CU Rexburg.cck
eCOMcheck Software Version 4.1.1.0
�(J Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
# I Plan Review
Ell
C103.2 Plans, specifications, and/or
[PR4]1 calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
C103.2 Plans, specifications, and/or
[PR8]1 calculations provide all information
with which compliance can be
determined for the exterior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
C406 Plans, specifications, and/or
1[PR9]1 calculations provide all information
with which compliance can be
determined for the additional energy
efficiency package options.
Additional Comments/Assumptions:
❑Complies
❑Does Not
Comments/Assumption s
Requirement will be met.
❑Not Observable Location on plans/spec: See plans and this document
❑Not Applicable
❑Complies Requirement will be met.
❑Does Not
❑Not Observable
Location on plans/spec: See plans and this document
❑Not Applicable
❑Complies Requirement will be met.
[]Does Not
❑Not Observable Location on plans/spec: See Documents and these
calculations
❑Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: East Idaho Credit Union Report date: 06/03/19
Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitledEast Page 4 of 8
Idaho CU Rexburg.cck
Section
Location on plans/spec: See lighting plans
-� -
#
Rough -In Electrical Inspection
Complies? Comments/Assumptions
& Req.ID
❑Not Observable
❑Not Observable
C405.2.1
Lighting controls installed to uniformly
[-]CompliesRequirement will be met.
[EL15]1
reduce the lighting load by at least
[]Does Not
allowed for special functions per the
50%.
Location on plans/spec: Manual dimmers in required spaces
❑Not Observable
❑Not Applicable
❑Not Observable
on lighting plans
❑Not Applicable
C405.2.1
Occupancy sensors installed in
❑Complies Requirement will be met.
[EL18]1
required spaces.
❑Does Not
lighting installed. Controls will be
❑Does Not
❑Not Observable Location on plans/spec: See restrooms
daylight controlled, set based on
❑Not Observable
❑Not Applicable
C405.2.1,
Independent lighting controls installed
❑Complies Requirement will be met.
C405.2.2.
per approved lighting plans and all
❑Does Not
3manual
controls readily accessible and
❑Not Observable Location on plans/spec: See lighting plans
[EL23]2
visible to occupants.
J
❑Not Observable
❑Not Applicable
C405.2.2. Automatic controls to shut off all
1 building lighting installed in all
[EL22]2 buildings.
C405.2.3 Daylight zones provided with
[EL16]2 individual controls that control the
lights independent of general area
lighting.
C405.2.3,
C405.2.3.
1,
C405.2.3.
2
I[EL20]1
C405.2.3,
C405.2.3.
1
C405.2.3.
3
[EL21]1
C405.2.4
[EL4]1
C405.2.4
[EL8]1
C405.2.5
[EL251"1
C405.3
[EL6]1
Primary sidelighted areas are
equipped with required lighting
controls.
❑Complies Exception: Lighting controlled by occupancy sensors
❑Does Not
❑Not Observable
Location on plans/spec: See lighting plans
❑Not Applicable
specific uses installed per approved
❑Complies
Requirement will be met.
❑Does Not
❑Not Observable
❑Not Observable
Location on plans/spec: See lighting plans
❑Not Applicable
❑Complies
Requirement will be met.
❑Does Not
allowed for special functions per the
❑Not Observable
Location on plans/spec: See lighting plans
❑Not Applicable
❑Not Observable
Enclosed spaces with daylight area ❑Complies Requirement will be met.
under skylights and rooftop monitors ❑Does Not
are equipped with required lighting ❑Not Observable Location on plans/spec: See lighting plans
controls.
❑Not Applicable
Separate lighting control devices for
❑Complies
Requirement will be met.
specific uses installed per approved
❑Does Not
lighting plans.
❑Not Observable
Location on plans/spec: See lighting plans
❑Not Applicable
Additional interior lighting power
❑Complies
Requirement will be met.
allowed for special functions per the
❑Does Not
approved lighting plans and is
❑Not Observable
Location on plans/spec: See lighting plans
automatically controlled and
separated from general lighting.
❑Not Applicable
Automatic lighting controls for exterior
❑Complies
Requirement will be met.
lighting installed. Controls will be
❑Does Not
daylight controlled, set based on
❑Not Observable
Location on plans/spec: See exterior lighting control detail
business operation time -of -day, or
reduce connected lighting > 30%.
❑Not Applicable
Exit signs do not exceed 5 watts per
❑Complies
Requirement will be met.
face.
❑Does Not
❑Not Observable
Location on plans/spec: See Igiht fixture schedule
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: East Idaho Credit Union Report date: 06103/19
Data filename: F:\Projects\19110_East Idaho Credit Union - Rexburg\Design Ana lysis\COMcheck\UntitledEast Page 5 of 8
Idaho CU Rexburg.cck
Section
Interior installed lamp and fixture
�
#
Final Inspection
Complies?
& RegJD
C303.3,
Furnished O&M instructions for
[]Complies
C408.2.5.
systems and equipment to the
[]Does Not
2
[FI1713
building owner or designated
representative.
❑Not Observable
❑Not Applicable
Comments/Assumptions
Requirement will be met.
C405A.1
Interior installed lamp and fixture
❑Complies
See the Interior Lighting fixture schedule for values.
[17I1831
lighting power is consistent with what
❑Does Not
is shown on the approved lighting
❑Not Observable
plans, demonstrating proposed watts
❑Not Applicable
are less than or equal to allowed
watts.
C405.5.1
Exterior lighting power is consistent
❑Complies
See the Exterior Lighting fixture schedule for values.
[FI19]1
with what is shown on the approved
❑Does Not
lighting plans, demonstrating
[-]Not Observable
proposed watts are less than or equal
❑Not Applicable
to allowed watts.
C408.2.5.
Furnished as -built drawings for
❑Complies
Requirement will be met.
1
electric power systems within 90 days
❑Does Not
[FI1613
of system acceptance.
❑Not Observable
❑Not Applicable
'C408.3
Lighting systems have been tested to
❑Complies
Requirement will be met.
[FI3311
ensure proper calibration, adjustment,
❑Does Not
programming, and operation.❑Not
Observable
Location on plans/spec: See Igiht fixture schedule
❑Not Applicable
Additional
Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: East Idaho Credit Union Report date: 06/03/19
Data filename: F:\Projects\19110 East Idaho Credit Union - Rexburg\Design Analysis\COMcheck\UntitleclEast Page 7 of 8
Idaho CU Rexburg.cck