Loading...
HomeMy WebLinkAboutCOMCHECK - 19-00359 - 871 Jet Stream Dr - The Rock Gym - New CommercialCOMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Title: The Rock Gym Rexburg Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Rexburg, ID 83440 JRW & Associates 1152 Bond Ave Rexburg, ID 83440 208-359-2309 Building Location (for weather data): Rexburg, Idaho --- Climate Zone: 6b 1.200 Vertical Glazing / Wall Area Pct.: 8% 138 Building -Use: Activity Tvpejs) Floor Area 1 -Exercise Center : Nonresidential 10800 Section 2: Envelope Assemblies and Requirements Checklist code.Envelope PASSES: Design 1 % better than 18.0 Envelope Assemblies: 0.069 Component Name/Description Gross Cavity Cont. Proposed Budget --- Area or R -Value R -Value U -Factor U -Factorial 0.550 Perimeter Roof 1: Metal Building, Screw Down, [Bldg. Use 1 - Exercise Center] Exterior Wall 1: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Exercise Center] Window 1: Metal Frame with Thermal Break, Perf. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center] Door 2: Glass (> 50% glazing):Nonmetal Frame, Entrance Door, Perf. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Exterior Wall 2: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Exercise Center] Window 2: Metal Frame with Thermal Break, Pert. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Door 3: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Exterior Wall 3: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Exercise Center] Window 3: Metal Frame with Thermal Break, Perf. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Door 4: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center] Door 5: Glass (> 50% glazing):Nonmetal Frame, Non -Entrance Door, Perf. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Exterior Wall 4: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Exercise Center] Window 4: Metal Frame with Thermal Break, Perf. Type: Energy code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 - Exercise Center] Project Title: The Rock Gym Rexburg Data filename: S:\Drawings\748-Martin Rock Wall\com check.cck 10800 0.0 30.0 0.032 0.049 3285 0.0 18.0 0.053 0.069 132 --- --- 1.100 0.550 21 --- --- 1.200 0.700 138 --- --- 0.950 0.350 3627 0.0 18.0 0.053 0.069 170 --- --- 1.100 0.550 64 --- --- 1.200 0.800 3334 0.0 18.0 0.053 0.069 72 --- --- 1.100 0.550 21 --- --- 0.600 0.700 400 --- 0.950 0.350 2861 0.0 18.0 0.053 0.069 120 --- --- 1.100 0.550 Report date: 06/17/19 Pane 1 of 2 (a) Budget LI -factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: LJ 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. L1 2. Windows, doors, and skylights certified as meeting leakage requirements. L] 3. Component R -values & LI -factors labeled as certified. 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels. 5. 'Other' components have supporting documentation for proposed LI -Factors. 6. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the insulation. Lj 7. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized dampers. Lj 8. Cargo doors and loading dock doors are weather sealed. Lj 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, are sealed with gasket or caulk. ❑ 10. Building entrance doors have a vestibule equipped with self-closing devices. Exceptions: 0 Building entrances with revolving doors. Ll Doors not intended to be used as a building entrance. L) Doors that open directly from a space less than 3000 sq. ft. in area. 0 Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors. LJ Doors opening directly from a sleeping/dwelling unit. Section 3: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2009 IECC requirements in COMcheck Version 4.1.1.0 and to comply with the mandatory requirements in the Requirements Checklist. Ryan Maim AIT _ - 06/17/2019 Name - Title Signature Date Project Title: The Rock Gym Rexburg Report date: 06/17/19 Data filename: S:\Drawings\748-Martin Rock Wall\corn check.cck Pace 2 of 2