HomeMy WebLinkAboutCOMCHECK - 19-00359 - 871 Jet Stream Dr - The Rock Gym - New CommercialCOMcheck Software Version 4.1.1.0
Envelope Compliance Certificate
Section 1: Project Information
Energy Code: 2009 IECC
Project Title: The Rock Gym Rexburg
Project Type: New Construction
Construction Site: Owner/Agent: Designer/Contractor:
Rexburg, ID 83440 JRW & Associates
1152 Bond Ave
Rexburg, ID 83440
208-359-2309
Building Location (for weather data): Rexburg, Idaho
---
Climate Zone: 6b
1.200
Vertical Glazing / Wall Area Pct.: 8%
138
Building -Use: Activity Tvpejs)
Floor Area
1 -Exercise Center : Nonresidential
10800
Section 2: Envelope Assemblies and Requirements Checklist
code.Envelope PASSES: Design 1 % better than
18.0
Envelope Assemblies:
0.069
Component Name/Description
Gross Cavity Cont. Proposed Budget
---
Area or R -Value R -Value U -Factor U -Factorial
0.550
Perimeter
Roof 1: Metal Building, Screw Down, [Bldg. Use 1 - Exercise Center]
Exterior Wall 1: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Exercise Center]
Window 1: Metal Frame with Thermal Break, Perf. Type: Energy
code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 -
Exercise Center]
Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center]
Door 2: Glass (> 50% glazing):Nonmetal Frame, Entrance Door,
Perf. Type: Energy code default, Single Pane, Clear, SHGC
0.80, [Bldg. Use 1 - Exercise Center]
Exterior Wall 2: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Exercise Center]
Window 2: Metal Frame with Thermal Break, Pert. Type: Energy
code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 -
Exercise Center]
Door 3: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.
Type: Energy code default, Single Pane, Clear, SHGC 0.80,
[Bldg. Use 1 - Exercise Center]
Exterior Wall 3: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Exercise Center]
Window 3: Metal Frame with Thermal Break, Perf. Type: Energy
code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 -
Exercise Center]
Door 4: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center]
Door 5: Glass (> 50% glazing):Nonmetal Frame, Non -Entrance
Door, Perf. Type: Energy code default, Single Pane, Clear,
SHGC 0.80, [Bldg. Use 1 - Exercise Center]
Exterior Wall 4: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Exercise Center]
Window 4: Metal Frame with Thermal Break, Perf. Type: Energy
code default, Single Pane, Clear, SHGC 0.80, [Bldg. Use 1 -
Exercise Center]
Project Title: The Rock Gym Rexburg
Data filename: S:\Drawings\748-Martin Rock Wall\com check.cck
10800 0.0 30.0 0.032 0.049
3285 0.0 18.0 0.053 0.069
132 --- --- 1.100 0.550
21
---
---
1.200
0.700
138
---
---
0.950
0.350
3627
0.0
18.0
0.053
0.069
170
---
---
1.100
0.550
64
---
---
1.200
0.800
3334
0.0
18.0
0.053
0.069
72
---
---
1.100
0.550
21
---
---
0.600
0.700
400
---
0.950
0.350
2861
0.0
18.0
0.053
0.069
120
---
---
1.100
0.550
Report date: 06/17/19
Pane 1 of 2
(a) Budget LI -factors are used for software baseline calculations ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requirements:
LJ 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance
with the manufacturer's installation instructions.
L1 2. Windows, doors, and skylights certified as meeting leakage requirements.
L] 3. Component R -values & LI -factors labeled as certified.
4. No roof insulation is installed on a suspended ceiling with removable ceiling panels.
5. 'Other' components have supporting documentation for proposed LI -Factors.
6. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that
achieves the rated R -value without compressing the insulation.
Lj 7. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized
dampers.
Lj 8. Cargo doors and loading dock doors are weather sealed.
Lj 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, are sealed with gasket or caulk.
❑ 10. Building entrance doors have a vestibule equipped with self-closing devices.
Exceptions:
0 Building entrances with revolving doors.
Ll Doors not intended to be used as a building entrance.
L) Doors that open directly from a space less than 3000 sq. ft. in area.
0 Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors.
LJ Doors opening directly from a sleeping/dwelling unit.
Section 3: Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2009 IECC
requirements in COMcheck Version 4.1.1.0 and to comply with the mandatory requirements in the Requirements Checklist.
Ryan Maim AIT _ - 06/17/2019
Name - Title Signature Date
Project Title: The Rock Gym Rexburg Report date: 06/17/19
Data filename: S:\Drawings\748-Martin Rock Wall\corn check.cck Pace 2 of 2