HomeMy WebLinkAboutTRUSS SPECS - 19-00353 - 2141 Summerfield Ln - New SFRJob
19-056118T
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:17 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-va8kkGI9tbPCejuZBawQC?b9zfXAx0jhjdBVE9zBIpC
Scale = 1:70.7
T2 T2
B1
W4
W3
W2
W1
W3
W2
W1T1 T1
B1B2B2
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3ST2
ST1
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3 ST2
ST1
A B
C
D
E
F
G
H I
L K JBEBFBGBH
5x6
5x6
5x8
2x4
5x8
3x4
5x8
4x5
5x8
3x4
5x8
5x6
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-1-11,Edge], [J:0-2-0,0-2-0], [J:0-4-0,0-3-0], [K:0-4-0,0-3-4], [L:0-4-0,0-3-0], [L:0-1-8,0-0-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.68
0.36
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
J-K
J-K
H
B-L
l/defl
>999
>851
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 303 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-8-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-11-7 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2046/0-5-8 (min. 0-2-3), H=2046/0-5-8 (min. 0-2-3)
Max Horz B=-186(LC 9)
Max UpliftB=-400(LC 8), H=-400(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3665/679, C-D=-3267/625, D-E=-2293/478, E-F=-2293/478, F-G=-3267/626,
G-H=-3665/680
BOT CHORD B-L=-693/3150, L-BE=-465/2567, BE-BF=-465/2567, K-BF=-465/2567, K-BG=-306/2567,
BG-BH=-306/2567, J-BH=-306/2567, H-J=-508/3150
WEBS E-K=-264/1418, F-K=-927/359, F-J=-108/558, G-J=-488/252, D-K=-927/359, D-L=-108/558,
C-L=-488/252
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=400,
H=400.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-056118T
Truss
A2
Truss Type
Common
Qty
24
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:21 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-nMOFaeLgxqvd7LBKQQ?MMrlryGu6tpiGeF9iNxzBIp8
Scale = 1:66.1
T2 T2
B1
W4 W3
W2
W1
W3
W2
W1T1 T1
B1B2B2AB
C
D
E
F
G
H I
L K JMNOP
5x6
5x6
5x8 5x8
3x4
5x8
5x8
3x4
5x8
5x6
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-1-11,Edge], [J:0-4-0,0-3-0], [K:0-4-0,0-3-4], [L:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.68
0.36
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
K-L
K-L
H
B-L
l/defl
>999
>851
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 188 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-8-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-11-7 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2046/0-5-8 (min. 0-2-3), H=2046/0-5-8 (min. 0-2-3)
Max Horz B=-186(LC 9)
Max UpliftB=-400(LC 8), H=-400(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3665/679, C-D=-3267/625, D-E=-2293/478, E-F=-2293/478, F-G=-3267/626,
G-H=-3665/680
BOT CHORD B-L=-693/3150, L-M=-465/2567, M-N=-465/2567, K-N=-465/2567, K-O=-306/2567,
O-P=-306/2567, J-P=-306/2567, H-J=-508/3150
WEBS E-K=-264/1418, F-K=-927/359, F-J=-108/558, G-J=-488/252, D-K=-927/359, D-L=-108/558,
C-L=-488/252
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=400,
H=400.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-056118T
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:24 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-Cx3NCgNZDlHC_owv6YY3_TNKwUtn455iKDOM_FzBIp5
Scale = 1:76.3
T2 T2
B1
W4
W3
W2
W1
W3
W2
W1T1 T1
B1B2B2
ST9
ST10
ST7
ST8
ST5
ST6
ST3
ST4ST2
ST1
ST9
ST7
ST8
ST5
ST6
ST3
A B
C
D
E
F
G
H I
L K JALAMANAOAPAQAR
5x6
5x6
7x10
3x6
7x10
3x4
7x10
5x8
3x6
5x8
5x6
2x4 2x4 2x4 2x4 2x4
2x4
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-12,0-0-3], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-3-0,0-2-9], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-3-0,0-0-3], [L:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.77
0.87
0.64
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.51
-0.71
0.13
0.32
(loc)
K-L
K-L
H
K-L
l/defl
>931
>668
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 295 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-7-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 8-3-13 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2422/0-5-8 (min. 0-2-9), H=2282/0-5-8 (min. 0-2-7)
Max Horz B=-186(LC 13)
Max UpliftB=-559(LC 8), H=-500(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-4617/1071, C-D=-4218/1014, D-E=-2885/722, E-F=-2885/722, F-G=-3800/838,
G-H=-4207/897
BOT CHORD B-L=-1040/4003, L-AL=-751/3262, AL-AM=-751/3262, AM-AN=-751/3262, AN-AO=-751/3262,
AO-AP=-751/3262, K-AP=-751/3262, K-AQ=-510/3073, AQ-AR=-510/3073, J-AR=-510/3073,
H-J=-703/3644
WEBS E-K=-482/1950, F-K=-886/376, F-J=-132/580, G-J=-496/256, D-K=-1153/451, D-L=-249/902,
C-L=-473/263
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=559,
H=500.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 204 lb down and 92 lb up at
13-5-12, and 204 lb down and 92 lb up at 15-5-12, and 204 lb down and 92 lb up at 17-5-12 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
Job
19-056118T
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:25 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-g7dlP?OB_2P3cyV6fF3IXhwVgtD0pYKsZt7wWizBIp4
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-84, E-I=-84, B-H=-14
Concentrated Loads (lb)
Vert: AM=-204(F) AN=-204(F) AP=-204(F)
Job
19-056118T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:27 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-cVlWqhPRWgfnrGfUng5mc6??4h5THbg90Bc0aazBIp2
Scale = 1:37.4
T1
T2
B1
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
B1
ST1
A
B
C
D
E
F
G
H
I
J
K
L
U T S R Q P O N M3x4
4x5
5x6
3x4
21-6-0
21-6-0
10-9-0
10-9-0
21-6-0
10-9-0
22-6-0
1-0-0
0-
4
-
3
5-
8
-
1
1
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [Q:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.04
0.08
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
L
K
K
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 100 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-6-0.
(lb) - Max Horz A=-113(LC 9)
Max Uplift All uplift 100 lb or less at joint(s) A, R, S, T, U, P, O, N, K, M
Max Grav All reactions 250 lb or less at joint(s) A, Q, R, S, T, P, O, N, K, M except U=280(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, R, S, T, U, P, O, N,
K, M.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-056118T
Truss
B2
Truss Type
Common
Qty
2
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:29 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-YutGFNRh2HvV4Zotu58EhX4HFVi7lTNSUV57fTzBIp0
Scale = 1:36.1
T1 T2
B1
W2
W1
W2
W1
B2
A
B
C
D
E
F
H G
3x6
4x5
5x6
1.5x4
3x4
1.5x4
3x6
7-2-0
7-2-0
14-4-0
7-2-0
21-6-0
7-2-0
5-4-8
5-4-8
10-9-0
5-4-8
16-1-8
5-4-8
21-6-0
5-4-8
22-6-0
1-0-0
0-
4
-
3
5-
8
-
1
1
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [G:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.34
0.35
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.13
0.04
0.04
(loc)
A-H
A-H
E
A-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 89 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)A=1036/0-3-8 (min. 0-1-8), E=1144/0-3-8 (min. 0-1-8)
Max Horz A=-113(LC 13)
Max UpliftA=-195(LC 8), E=-229(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1865/345, B-C=-1606/334, C-D=-1595/329, D-E=-1853/339
BOT CHORD A-H=-334/1580, G-H=-121/1028, E-G=-223/1566
WEBS C-G=-147/563, D-G=-438/221, C-H=-153/579, B-H=-446/224
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=195,
E=229.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-056118T
Truss
C1
Truss Type
Common
Qty
1
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:31 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-UH_1g3SyauADKtyF0WAimyAg3ITiDQEkxpaEjMzBIp_
Scale = 1:24.4
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
I
N M L K J
4x5
3x4 3x4
13-4-0
13-4-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
14-4-0
1-0-0
0-
4
-
3
3-
8
-
3
0-
4
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 55 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-4-0.
(lb) - Max Horz B=68(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) H.
11) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-056118T
Truss
C2
Truss Type
Common
Qty
3
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:33 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-Rf6n5lUC6WQwZB6e7xCAsNFvG62LhJh1O73LnEzBIoy
Scale = 1:23.2
T1
T2
B1
W1
A
B
C
D
E
5x6
3x6 3x6 1.5x4
6-8-0
6-8-0
13-4-0
6-8-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
0-
4
-
3
3-
8
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8], [D:0-2-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.53
0.40
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.12
0.01
0.05
(loc)
D-E
D-E
D
D-E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-8-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)D=625/0-5-8 (min. 0-1-8), B=745/0-5-8 (min. 0-1-8)
Max Horz B=77(LC 8)
Max UpliftD=-118(LC 9), B=-155(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-906/156, C-D=-903/151
BOT CHORD B-E=-84/690, D-E=-84/690
WEBS C-E=0/261
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) D=118,
B=155.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-056118T
Truss
J1
Truss Type
Jack-Open
Qty
3
Ply
1
KARTCHNER SF14BB8 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Thu May 30 12:00:34 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-vsg9I4VqtpYnBLhqhejPOao73WSaQnzBdnpuJgzBIox
Scale = 1:17.3
T1
B1
W1
A
B
C
D
1.5x4
2x4 1.5x4
5-0-0
5-0-0
-1-0-0
1-0-0
5-0-0
5-0-0
0-
4
-
3
2-
1
0
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.34
0.14
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.04
0.00
0.00
(loc)
B-D
B-D
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 19 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=346/0-3-8 (min. 0-1-8), D=218/Mechanical
Max Horz B=118(LC 8)
Max UpliftB=-67(LC 8), D=-78(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard