HomeMy WebLinkAboutTRUSS ENGINEERING - 19-00352 - 2149 Summerfield Ln - New SFRJob 19-066717T Truss A1 Truss Type GABLE Qty 1 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:00 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-7ANxAwIIIz3FCEkFmkMED26NYu8qidD0fjAchlz6hGT Scale = 1:87.2 T3 T3 B1 W4 W3 W2 W1 W4W3 W2 W1 T1 T2 T4 T2 B1B2B2B2 ST19 ST17 ST18 ST15 ST16 ST13 ST14 ST11 ST12ST10 ST8 ST9 ST6 ST7 ST5ST4ST3 ST2 ST1 ST17 ST18 ST15 ST16 ST13 ST14 ST11 ST12 ST10 ST8 ST9 ST6 ST7 ST5 ST4 ST3 ST2 ST1 A B C D E F G H L K J IBRBSBTBUBVBW 7x10 6x8 7x10 5x8 7x10 3x6 7x10 7x10 7x10 7x10 7x10 5x8 10-8-0 10-8-0 21-4-0 10-8-0 32-0-0 10-8-0 42-8-0 10-8-0 53-4-0 10-8-0 -1-0-0 1-0-0 8-10-11 8-10-11 17-9-5 8-10-11 26-8-0 8-10-11 35-6-11 8-10-11 44-5-5 8-10-11 53-4-0 8-10-11 0- 6 - 3 11 - 7 - 9 0- 6 - 3 5.00 12 Plate Offsets (X,Y)-- [B:0-2-1,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [E:0-2-0,0-0-0], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-1-5,Edge], [I:0-1-8,0-0-2], [I:0-5-0,0-4-8], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-3-0,0-2-8], [L:0-5-0,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.51 0.62 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.45 -0.64 0.21 0.21 (loc) J-K J-K H K l/defl >999 >988 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 513 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std OTHERS 2x4 DF Stud/Std *Except* ST19: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BRACING- TOP CHORD Sheathed or 3-0-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-2-2 oc bracing. WEBS 1 Row at midpt F-J, D-K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=2711/0-5-8 (min. 0-2-14), H=2598/Mechanical Max Horz B=211(LC 12) Max UpliftB=-534(LC 8), H=-500(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-5722/1062, C-D=-5397/1071, D-E=-4134/831, E-F=-4145/836, F-G=-5479/1092, G-H=-5811/1085 BOT CHORD B-L=-1085/5132, L-BR=-767/4174, BR-BS=-767/4174, K-BS=-767/4174, K-BT=-410/3109, BT-BU=-410/3109, J-BU=-410/3109, J-BV=-578/4196, BV-BW=-578/4196, I-BW=-578/4196, H-I=-914/5230 WEBS E-J=-362/1372, F-J=-1192/465, F-I=-280/1080, G-I=-675/318, E-K=-357/1353, D-K=-1169/459, D-L=-263/1014, C-L=-631/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=534, H=500. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-066717T Truss A2 Truss Type Common Qty 6 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:03 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-Xl23oyKAbuRq3iTqSswxqgkuo69Xv_zSLhPGI4z6hGQ Scale = 1:87.2 T3 T3 B1 W4 W3 W2 W1 W4W3 W2 W1 T1 T2 T4 T2 B1B2B2B2AB C D E F G H L K J IMNOPQR 7x10 6x8 7x10 5x8 7x10 7x10 7x10 7x10 7x10 7x10 5x8 10-8-0 10-8-0 21-4-0 10-8-0 32-0-0 10-8-0 42-8-0 10-8-0 53-4-0 10-8-0 -1-0-0 1-0-0 8-10-11 8-10-11 17-9-5 8-10-11 26-8-0 8-10-11 35-6-11 8-10-11 44-5-5 8-10-11 53-4-0 8-10-11 0- 6 - 3 11 - 7 - 9 0- 6 - 3 5.00 12 Plate Offsets (X,Y)-- [B:0-1-5,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-1-5,Edge], [I:0-5-0,0-4-8], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-5-0,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.51 0.62 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.45 -0.64 0.21 0.21 (loc) J-K J-K H K l/defl >999 >988 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 330 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 3-0-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-2-2 oc bracing. WEBS 1 Row at midpt F-J, D-K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=2711/0-5-8 (min. 0-2-14), H=2598/Mechanical Max Horz B=211(LC 12) Max UpliftB=-534(LC 8), H=-500(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-5722/1062, C-D=-5397/1071, D-E=-4134/831, E-F=-4145/836, F-G=-5479/1092, G-H=-5811/1085 BOT CHORD B-L=-1085/5132, L-M=-767/4174, M-N=-767/4174, K-N=-767/4174, K-O=-410/3109, O-P=-410/3109, J-P=-410/3109, J-Q=-578/4196, Q-R=-578/4196, I-R=-578/4196, H-I=-914/5230 WEBS E-J=-362/1372, F-J=-1192/465, F-I=-280/1080, G-I=-675/318, E-K=-357/1353, D-K=-1169/459, D-L=-263/1014, C-L=-631/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) All plates are 7x10 MT20 unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=534, H=500. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-066717T Truss A3 Truss Type Common Qty 3 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:05 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-T8ApDeMQ6WhYI?dCZHyPv5qFevsdNuZlo?uMMzz6hGO Scale = 1:87.5 T3 T3 B1 W4 W3 W2 W1 W4W3 W2 W1 W5T1 T2 T5 T4 B1B2B2B2AB C D E F G HI N M L K JOPQRST 7x10 6x8 7x10 5x8 7x10 7x10 7x10 7x10 7x10 7x10 4x5 5x6 10-8-0 10-8-0 21-4-0 10-8-0 32-0-0 10-8-0 42-8-0 10-8-0 46-11-8 4-3-8 53-4-0 6-4-8 -1-0-0 1-0-0 8-10-11 8-10-11 17-9-5 8-10-11 26-8-0 8-10-11 35-6-11 8-10-11 44-5-5 8-10-11 53-4-0 8-10-11 54-4-0 1-0-0 0- 6 - 3 11 - 7 - 9 0- 6 - 3 5.00 12 Plate Offsets (X,Y)-- [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-5-0,0-4-8], [M:0-5-0,0-4-8], [N:0-5-0,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.42 0.51 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.30 -0.43 0.12 0.14 (loc) M-N M-N J M-N l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 338 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1,W5: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 3-5-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt E-L, F-L, F-K, D-M, G-J MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=2341/0-5-8 (min. 0-2-8), J=3065/0-5-8 (min. 0-3-4) Max Horz B=204(LC 8) Max UpliftB=-490(LC 8), J=-603(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-4798/954, C-D=-4472/963, D-E=-3185/720, E-F=-2720/564, F-G=-1703/346, G-H=-350/1161 BOT CHORD B-N=-979/4284, N-O=-658/3302, O-P=-658/3302, M-P=-658/3302, M-Q=-300/2232, Q-R=-300/2232, L-R=-300/2232, L-S=-314/2425, S-T=-314/2425, K-T=-314/2425, J-K=-111/866, H-J=-929/377 WEBS E-L=-162/574, F-L=-332/264, F-K=-1458/247, G-K=-96/1264, E-M=-358/1356, D-M=-1173/460, D-N=-266/1026, C-N=-638/308, G-J=-3346/684 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) All plates are 7x10 MT20 unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=490, J=603. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-066717T Truss A4 Truss Type Common Qty 10 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:07 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-QWIaeJNhe7xGXJnbhi_t?Wvbojc9rkR2GJNTRrz6hGM Scale = 1:87.3 T3 T3 B1 W1 W2 W3 W4 W5 W6 W2 W1T1 T2 T1 T2 B1B4B3B2AB C D E F G H I M L K JNOPQRS 7x10 6x8 7x10 4x5 7x10 7x10 7x10 7x10 7x10 7x10 4x5 10-8-0 10-8-0 21-4-0 10-8-0 30-10-4 9-6-4 31-1-0 0-2-12 42-8-0 11-7-0 53-4-0 10-8-0 -1-0-0 1-0-0 8-10-11 8-10-11 17-9-5 8-10-11 26-8-0 8-10-11 35-6-11 8-10-11 44-5-5 8-10-11 53-4-0 8-10-11 54-4-0 1-0-0 0- 6 - 3 11 - 7 - 9 0- 6 - 3 5.00 12 Plate Offsets (X,Y)-- [B:0-2-1,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-2-9,Edge], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-5-0,0-4-8], [M:0-5-0,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.44 0.32 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.21 0.03 0.07 (loc) L-M L-M K B-M l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 333 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 5-2-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: B-M. WEBS 1 Row at midpt D-L, F-K 2 Rows at 1/3 pts E-K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=1243/0-5-8 (min. 0-1-8), K=3468/0-5-8 (min. 0-3-11), H=693/0-3-8 (min. 0-1-8) Max Horz B=204(LC 12) Max UpliftB=-304(LC 8), K=-543(LC 8), H=-222(LC 9) Max GravB=1347(LC 19), K=3468(LC 1), H=882(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-2316/488, C-D=-1987/496, D-E=-640/244, E-F=-121/1461, F-G=-843/417, G-H=-1176/361 BOT CHORD B-M=-552/2007, M-N=-220/964, N-O=-220/964, L-O=-220/964, L-P=-367/339, P-Q=-367/339, K-Q=-367/339, K-R=-641/221, R-S=-641/221, J-S=-641/221, H-J=-304/963 WEBS C-M=-679/316, D-M=-276/1093, D-L=-1193/464, E-L=-368/1328, E-K=-2447/508, F-K=-1229/470, F-J=-275/1131, G-J=-705/322 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) All plates are 7x10 MT20 unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=304, K=543, H=222. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-066717T Truss A5 Truss Type GABLE Qty 1 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:11 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-IIX5UhQBiMSh0w4MwY3p9M4GVKuvnb5eBwLhacz6hGI Scale = 1:87.2 T3 T3 B1 W4 W3 W2 W1 W4W3 W2 W1 ST19 ST17 ST18 ST15 ST16 ST13 ST14 ST11 ST12ST10 ST8 ST9 ST6 ST7 ST5ST4ST3 ST2ST1 ST17 ST18 ST15 ST16 ST13 ST14 ST11 ST12 ST10 ST8 ST9 ST6 ST7 ST5 ST4 ST3 ST2 ST1 T2 T2 B1B2B2B2AB C D E F G H I M L K JBSBTBUBVBWBX 7x10 6x8 7x10 5x8 7x10 3x6 7x10 7x10 7x10 7x10 7x10 5x8 10-8-0 10-8-0 21-4-0 10-8-0 32-0-0 10-8-0 42-8-0 10-8-0 53-4-0 10-8-0 -1-0-0 1-0-0 8-10-11 8-10-11 17-9-5 8-10-11 26-8-0 8-10-11 35-6-11 8-10-11 44-5-5 8-10-11 53-4-0 8-10-11 54-4-0 1-0-0 0- 6 - 3 11 - 7 - 9 0- 6 - 3 5.00 12 Plate Offsets (X,Y)-- [B:0-2-1,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [E:0-2-0,0-0-0], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-2-1,Edge], [J:0-1-8,0-0-2], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8] , [L:0-5-0,0-4-8], [M:0-3-0,0-2-8], [M:0-5-0,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.46 0.59 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.44 -0.63 0.21 0.20 (loc) K-L K-L H L l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 515 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std OTHERS 2x4 DF Stud/Std *Except* ST19: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BRACING- TOP CHORD Sheathed or 3-1-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-2-8 oc bracing. WEBS 1 Row at midpt F-K, D-L MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=2702/0-5-8 (min. 0-2-14), H=2702/0-5-8 (min. 0-2-14) Max Horz B=204(LC 8) Max UpliftB=-533(LC 8), H=-533(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-5699/1059, C-D=-5373/1068, D-E=-4110/828, E-F=-4110/828, F-G=-5373/1069, G-H=-5699/1060 BOT CHORD B-M=-1076/5110, M-BS=-757/4151, BS-BT=-757/4151, L-BT=-757/4151, L-BU=-400/3087, BU-BV=-400/3087, K-BV=-400/3087, K-BW=-553/4151, BW-BX=-553/4151, J-BX=-553/4151, H-J=-873/5110 WEBS E-K=-357/1353, F-K=-1169/460, F-J=-264/1015, G-J=-631/306, E-L=-357/1353, D-L=-1169/459, D-M=-263/1015, C-M=-631/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=533, H=533. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-066717T Truss B1 Truss Type Common Qty 1 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:13 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-EgfruNSSEziPFEEl1z5HEn9i78j6FgOxeEqoeVz6hGG Scale = 1:27.6 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 HW1 HW1 A B C D E F G H I J K P O N M L 4x5 3x4 3x4 3x4 3x4 13-4-0 13-4-0 -1-0-0 1-0-0 6-8-0 6-8-0 13-4-0 6-8-0 14-4-0 1-0-0 0- 8 - 3 4- 6 - 1 4 0- 8 - 3 7.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.03 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) J J J l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E OTHERS 2x4 DF Stud/Std SLIDER Left 2x4 DF Stud/Std 1-6-8, Right 2x4 DF Stud/Std 1-6-8 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-4-0. (lb) - Max Horz B=118(LC 7) Max Uplift All uplift 100 lb or less at joint(s) B, J, O, M except P=-109(LC 8), L=-105(LC 9) Max Grav All reactions 250 lb or less at joint(s) N, O, P, M, L except B=256(LC 1), J=256(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, J, O, M except (jt=lb) P=109, L=105. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-066717T Truss B2 Truss Type Common Girder Qty 1 Ply 2 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:15 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-B3nbJ3Timay7VYO79O8lJCEy2xFYjUoD6YJujOz6hGE Scale = 1:28.0 T1 T1 B1 W2 W1 W2 W1 A B C D E G FHIJK L M 7x10 9x12 MT18HS 7x10 12x12 1.5x4 12x12 1.5x4 4-5-5 4-5-5 8-10-11 4-5-5 13-4-0 4-5-5 3-4-0 3-4-0 6-8-0 3-4-0 10-0-0 3-4-0 13-4-0 3-4-0 0- 8 - 3 4- 6 - 1 4 0- 8 - 3 7.00 12 Plate Offsets (X,Y)-- [E:0-2-1,Edge], [F:0-6-0,0-8-0], [G:0-6-0,0-8-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.49 0.60 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.12 -0.17 0.03 0.06 (loc) F-G F-G E F-G l/defl >999 >891 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 171 lb FT = 20% GRIP 220/195 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x10 DF 1950F 1.7E or 2x10 DF SS WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 3-10-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)A=7905/0-5-8 (min. 0-4-3), E=8859/0-5-8 (min. 0-4-12) Max Horz A=-105(LC 6) Max UpliftA=-1545(LC 8), E=-1733(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-11112/2167, B-C=-10958/2181, C-D=-11056/2201, D-E=-11210/2187 BOT CHORD A-H=-1823/9172, H-I=-1823/9172, G-I=-1823/9172, G-J=-1239/6529, J-K=-1239/6529, F-K=-1239/6529, F-L=-1770/9258, L-M=-1770/9258, E-M=-1770/9258 WEBS C-F=-1250/6190, D-F=-273/707, C-G=-1215/6017, B-G=-274/710 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-3-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=1545, E=1733. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2584 lb down and 514 lb up at 2-0-12, 2584 lb down and 514 lb up at 4-0-12, 2584 lb down and 514 lb up at 6-0-12, 2584 lb down and 514 lb up at 8-0-12, and 2584 lb down and 514 lb up at 10-0-12, and 2584 lb down and 514 lb up at 12-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 Job 19-066717T Truss B2 Truss Type Common Girder Qty 1 Ply 2 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:16 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-fFL_XOUKXu4_7izKi5f_sQn6oLbnSx1NKC2SFqz6hGD LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: A-C=-84, C-E=-84, A-E=-14 Concentrated Loads (lb) Vert: H=-2584(B) I=-2584(B) J=-2584(B) K=-2584(B) L=-2584(B) M=-2584(B) Job 19-066717T Truss V1 Truss Type GABLE Qty 1 Ply 1 KARTCHNER SF14AB8 ATHENS Job Reference (optional) 8.220 s Feb 10 2019 MiTek Industries, Inc. Thu Jun 13 12:16:17 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:qaPR0EfO3v25RskfiguOwDzdfvS-7SuMkkVyICCrkrXWGpADPdJNal3MBTwWZso?oGz6hGC Scale = 1:36.3 T1 T1 B1 ST4 ST3 ST2 B1 ST1 ST3 ST2 ST1 A B C D E F G H I P O N M L K J3x4 4x5 3x4 5x6 19-10-8 19-10-8 9-11-4 9-11-4 19-10-8 9-11-4 0- 0 - 4 5- 9 - 9 0- 0 - 4 7.00 12 Plate Offsets (X,Y)-- [M:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.10 0.07 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - I l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E OTHERS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 19-10-8. (lb) - Max Horz A=-143(LC 4) Max Uplift All uplift 100 lb or less at joint(s) A, I, N, O, L, K except P=-131(LC 8), J=-131(LC 9) Max Grav All reactions 250 lb or less at joint(s) A, I, M, N, O, L, K except P=339(LC 19), J=339(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS B-P=-265/141, H-J=-265/141 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, I, N, O, L, K except (jt=lb) P=131, J=131. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard