Loading...
HomeMy WebLinkAboutITD-0288_20181001 (2).pdf Page 1 of 2 Curb Ramp Inspection ITD 0288 (Rev. 02-17) itd.idaho.gov Key Number Ramp ID Number or Specify New Date Inspected Inspected By (Print & Signature) District City County Highway Milepost COMPLIANT (*All items must be within minimum/maximum tolerance to be compliant; do not leave blanks where measurements are required.) Yes* No Provide Technical Infeasibility Reason & Explanation: Ramp Location Location in Intersection Curb Ramp Type Other (check any that apply) Corner Mid-block N E NW NE S W SW SE Perpendicular (1 Area) Parallel (2 Areas) Combined (3 Areas) Sidewalk Curb & Gutter Marked Crosswalk Describe Ramp Location (details to help locate it, such as “facing Main Street next to the Shell station”) Refer to the Smart Level Measurement Locations detailed on Page 2 *Ramp Details (see attached) Ramped Area 1 Ramped Area 2 Ramped Area 3 Ramped Area 4 Ramp Width (48” minimum) (1) Running Slope (8.3% maximum) (2) Cross Slope (2% maximum) (3) Flare Slope A (10% maximum ) (4) Flare Slope B (10% maximum ) (5)Landing (Turning Space) Yes No Width (48” minimum) Length (48” minimum) (5) Cross Slope (2% maximum - both directions) W L *Detectable Warning Surface Detectable Warning Length (24” minimum) Detectable Warning Spans Width of Curb Cut Truncated Dome Spacing Correct as Noted on Standard Drawing Yes No (not compliant) Yes No Within 5’ of the Curb Line/Grade Break Color Contrast (e.g., Light on Dark or Dark on Light) Yes No Yes No *Transition Details (enter measurement) Lip Present (> ¼ inch) (6) Gutter Flowline Slope at Ramp (2% maximum) (7) Gutter Counter Slope (5% maximum) Yes (not compliant) No Pedestrian Crossing Details Pedestrian Signal Pushbutton Pushbutton Height within 15" to 48" Pushbutton within 10” of clear space Crosswalk Clear Space Yes No Yes No (not compliant) Yes No (not compliant) Yes No (Provide Explanation in comment section) Page 2 of 2 Comments: ITD Office Use Only Ramp Accepted by DE Ramp Inventory Updated by 0288 Form Filed in ProjectWise by Ramp Compliant per standard ADA Ramp Inspection Details: (For detailed information on design parameters, please reference ITD’s standard drawings online at: http://www.itd.idaho.gov/design/StandardDrawings.htm) A ramp gradient measurement is required at locations marked with smart level below Perpendicular Curb Ramp - 1 Ramped Area Gutter Flowline Gutter Counter Slope Detectable Warning (Truncated Domes) Landing (Turning Space) Ramp Flare Flare Parallel Curb Ramp - 2 Ramped Areas Combination Curb Ramp - 3 Ramped Areas Ramp Ramp Ramp Ramp Flare Flare Landing (Turning Space) Landing (Turning Space) Ramp 1 2 5 7 6 3 4 Ramp Transition location–no lip >1/4”should be present