HomeMy WebLinkAboutITD-0288_20181001 (2).pdf Page 1 of 2
Curb Ramp Inspection ITD 0288 (Rev. 02-17)
itd.idaho.gov
Key Number Ramp ID Number or Specify New Date Inspected Inspected By (Print & Signature)
District City County Highway Milepost
COMPLIANT
(*All items must be within minimum/maximum tolerance to be compliant; do not leave blanks where measurements are required.)
Yes*
No Provide Technical Infeasibility Reason & Explanation:
Ramp Location Location in Intersection Curb Ramp Type Other (check any that apply)
Corner
Mid-block
N E NW NE
S W SW SE
Perpendicular (1 Area)
Parallel (2 Areas)
Combined (3 Areas)
Sidewalk
Curb & Gutter
Marked Crosswalk
Describe Ramp Location (details to help locate it, such as “facing Main Street next to the Shell station”)
Refer to the Smart Level Measurement Locations detailed on Page 2
*Ramp Details (see attached) Ramped Area 1 Ramped Area 2 Ramped Area 3 Ramped Area 4
Ramp Width (48” minimum)
(1) Running Slope (8.3% maximum)
(2) Cross Slope (2% maximum)
(3) Flare Slope A (10% maximum )
(4) Flare Slope B (10% maximum )
(5)Landing (Turning Space)
Yes
No
Width (48” minimum) Length (48” minimum) (5) Cross Slope (2% maximum - both
directions)
W L
*Detectable Warning Surface
Detectable Warning Length (24” minimum) Detectable Warning Spans Width of Curb
Cut
Truncated Dome Spacing Correct as
Noted on Standard Drawing
Yes No (not compliant) Yes No
Within 5’ of the Curb Line/Grade Break Color Contrast (e.g., Light on Dark or Dark on Light)
Yes No Yes No
*Transition Details (enter measurement)
Lip Present (> ¼ inch) (6) Gutter Flowline Slope at Ramp (2% maximum) (7) Gutter Counter Slope (5% maximum)
Yes (not compliant)
No
Pedestrian Crossing Details
Pedestrian Signal Pushbutton Pushbutton Height within 15" to 48" Pushbutton within 10” of clear space Crosswalk Clear Space
Yes No Yes No (not compliant) Yes No (not compliant)
Yes
No (Provide
Explanation in
comment section)
Page 2 of 2
Comments:
ITD Office Use Only
Ramp Accepted by DE
Ramp Inventory Updated by
0288 Form Filed in ProjectWise by
Ramp Compliant per standard
ADA Ramp Inspection Details: (For detailed information on design parameters, please reference ITD’s
standard drawings online at: http://www.itd.idaho.gov/design/StandardDrawings.htm)
A ramp gradient measurement is required at locations marked with smart level below
Perpendicular Curb Ramp - 1 Ramped Area
Gutter Flowline
Gutter Counter Slope
Detectable Warning
(Truncated Domes)
Landing
(Turning Space)
Ramp Flare Flare
Parallel Curb Ramp - 2 Ramped Areas Combination Curb Ramp - 3 Ramped Areas
Ramp Ramp Ramp Ramp
Flare Flare
Landing
(Turning Space)
Landing
(Turning Space)
Ramp
1
2
5
7
6
3 4
Ramp Transition location–no lip
>1/4”should be present