HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00573 - 486 S 3rd W - The Roost - Bldg #2 - MFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/03/2019 3:20 pm Permit Details Permit Number: 16-00573 486 S 3rd W - The Roost - Bldg #2 - MFR 486 S 3rd W New Multi-Family Residential/Dormitory Permit Issued Date: 10/27/2016 Permit Inspection Statistics 40Total Inspections Completed: 26Total Inspections Passed: Inspection Pass Rate: 65.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 06/03/2019PassQuinton OwensPublic Works Final Inspection Public Works final approved for entire site on Building 3 per conversation with Joel G. Inspector Comments: 06/03/2019PassQuinton OwensPlanning and Zoning Final Inspection * Building 2 approved for P&Z. * P&Z final approval for the Roost site will be on building 3 (17-00310) Inspector Comments: Building Inspection Type 09/26/2016PassTed DyeResidential Footing Inspection South building.Inspector Comments: 09/27/2016PassTed DyeFoundation Inspection 09/30/2016PassTed DyeResidential Insulation Inspection 10/12/2016PassTed DyeCommercial Footing Inspection 12/13/2016FailQuinton OwensSheeting Missed nailing locations: 1st floor- About 10" south of west side window in SW unit. 2nd floor- Nails missed stud above stair landing under window; stud near south side of window on east side and one side of joint east of north window next to jog in exterior wall; joint under window on east side is missing backing. 3rd floor. East side several nails missed a stud (look for nails pushed back out) Inspector Comments: Third level framing only.Inspector Comments: 01/12/2017FailQuinton OwensCommercial Framing/Structure Inspection Sheeting has not been re-inspected for the 12/13 inspection.Inspector Comments: Finish sheeting corrections from December's inspection.Inspector Comments: One exhaust fan vent found to be very restricted by PVC pipe against it near fan.Inspector Comments: Type B unit compliance is required as noted in plan review comments.Inspector Comments: 01/13/2017FailQuinton OwensCommercial Framing/Structure Inspection Inspected 1st and 2nd floors. Re-inspection on 3rd floor (approved to insulate 3rd level). Inspector Comments: Level 2 & 3 only.Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 16-00573 486 S 3rd W - The Roost - Bldg #2 - MFR 486 S 3rd W New Multi-Family Residential/Dormitory Permit Status of (Open) as of Report Date: 06/03/2019 3:20 pm Permit Inspection Summary 01/17/2017PARTPASSQuinton OwensCommercial Insulation Inspection Found blown insulation in smaller gaps in studs not properly filled - foam seal gaps as needed. Inspector Comments: 01/20/2017PARTPASSQuinton OwensCommercial Sheetrock/Drywall Inspection 2nd & 3rd level drywallInspector Comments: 01/20/2017FailQuinton OwensCommercial Framing/Structure Inspection First level framing re-inspect. Several corrections still needed. Returned at end of day but were not done. Call for reinspect. Inspector Comments: 01/20/2017PARTPASSQuinton OwensCommercial Insulation Inspection 01/25/2017FailTed DyeCommercial Sheetrock/Drywall Inspection Sheetrock has been failed because of items still left to be completed and inspected. Please call for a framing inspection and be prepared to remove drywall in those areas to be inspected. Inspector Comments: 01/27/2017FailTed DyeCommercial Framing/Structure Inspection 01/27/2017PassTed DyeCommercial Sheetrock/Drywall Inspection Fire rate penetrations in separation walls and ceilings (typ. under sinks, behind toilets, and in water heater closets. Inspector Comments: Missing one HC parking stall and marked access aisle. Identification signs will also be needed. Inspector Comments: 03/29/2017FailQuinton OwensCommercial Building Final 2204: back bdrm smoke detector is not interconnected. Inspector Comments: Approved for TEMPORARY C.O. - Landscaping & handicap parking to be completed. Inspector Comments: 03/31/2017FailQuinton OwensCommercial Building Final Finish taping joints and fire rating penetrations in riser room within a week.Inspector Comments: 05/10/2017FailQuinton OwensCommercial Building Final Fire riser rooms have several penetrations that have not been fire rated.Inspector Comments: 09/25/2017FailQuinton OwensCommercial Building Final Fire rating inside rise room: * Penetrations fire caulked, but data line penetrations are not rated. Complete fire rating ASAP. Inspector Comments: 12/17/2018PassQuinton OwensSheeting Re-inspected from inside with framing inspection (building wrapped with windows installed) Inspector Comments: 12/18/2018PassQuinton OwensCommercial Framing/Structure Inspection Page 2 of 4 (Continued) Permit Details Permit Number: 16-00573 486 S 3rd W - The Roost - Bldg #2 - MFR 486 S 3rd W New Multi-Family Residential/Dormitory Permit Status of (Open) as of Report Date: 06/03/2019 3:20 pm Permit Inspection Summary 12/18/2018PassTed DyeCommercial Building Final Building final approved for occupancy - pending all finals completed.Inspector Comments: 06/03/2019PassQuinton OwensSidewalk Inspection Joel said he is good with sidewalks, but is wondering about required lighting required with building 3 being a "street building". This will be checked on the P&Z final for building 3. Inspector Comments: Electrical Inspection Type 12/07/2016PassBret StoddardCOM & MFR Electrical Service Inspection 01/13/2017PassBret StoddardResidential Electrical Rough-in 03/30/2017PassBret StoddardCommerical Electrical Final Inspection 12/27/2017FailBret StoddardResidential Electrical Final Inspection This inspection belongs to Roost building #3 (17-00310)Inspector Comments: Fire Inspection Type 03/31/2017PassQuinton OwensFire Alarm Final Inspection The Roost building 1 & 2 are on one fire alarm system and were tested and inspected together. Inspector Comments: 04/06/2017PassDale PickeringFire Sprinkler Final Inspection 04/19/2017PassDale PickeringFire Sprinkler Rough-in 06/03/2019PassQuinton OwensFire Department Final Inspection Fire Dept. final approved for entire site on Building 3 per conversation with Dale P. Inspector Comments: 06/03/2019PassQuinton OwensFire Underground Inspection Done with Building 1 per discussion with Joel G.Inspector Comments: 06/03/2019PassQuinton OwensFire Sprinkler Hydro Checklist shows completed and is completed per Dale P.Inspector Comments: Mechanical Inspection Type 01/12/2017PassDon AllenHVAC Rough-in 03/29/2017PassDon AllenHVAC Final Inspection Page 3 of 4 (Continued) Permit Details Permit Number: 16-00573 486 S 3rd W - The Roost - Bldg #2 - MFR 486 S 3rd W New Multi-Family Residential/Dormitory Permit Status of (Open) as of Report Date: 06/03/2019 3:20 pm Permit Inspection Summary Plumbing Inspection Type 09/30/2016PassDon AllenPlumbing Water 09/30/2016PassDon AllenPlumbing Sewer Good to cover the sewer lineInspector Comments: 01/17/2017PassDon AllenPlumbing Water Water lines on the 2nd and 3 floor was covere. Water lines held air test Inspector Comments: 03/29/2017PassDon AllenPlumbing Final Inspection Page 4 of 4