Loading...
HomeMy WebLinkAboutCOMCHECK - 16-00334, 16-00573 - 486 S 3rd W - The Roost - Bldg #1 & #2 - MFRREScheck Software Version 4.6.2 Compliance Certificate Project Energy Code:2012 IECC Location:Rexburg, Idaho Construction Type:Multi-family Project Type:New Construction Conditioned Floor Area:11,600 ft2 Glazing Area 14% Climate Zone:6 (8693 HDD) Permit Date: Construction Site:Owner/Agent:Designer/Contractor: Permit Number: Compliance: Passes using UA trade-off 0.3% Better Than Code Maximum UA:865 Your UA:862 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 3,896 0.0 50.0 0.019 74 Wall 1: Wood Frame, 16" o.c.6,816 22.0 0.0 0.056 329 Window 1: Vinyl/Fiberglass Frame:Triple Pane with Low-E 900 0.280 252 Door 1: Glass 36 0.320 12 Floor 1: Slab-On-Grade:Heated Insulation depth: 3.0' 278 10.0 0.702 195 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Data filename: C:\Users\Jonathan\Dropbox\Roost\Reports\roost res check.rck Page 1 of 1 09/22/16Report date: