HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00052 - 250 W 1st N - 12 Plex - Bear Building 1 - EastPermit
Inspection
Summary
Permit Status of (Expired) as of Report Date: 05/31/2019 10:10 am
Permit Details Permit Number: 16-00052
250 W 1st N - 12 Plex - Bear Building 1 - East
250 W 1st N
New Multi-Family Residential/Dormitory
Permit Issued Date: 03/03/2016
Permit Inspection Statistics
34Total Inspections Completed:
22Total Inspections Passed:
Inspection Pass Rate: 64.71%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
02/12/2016PassTed DyeCommercial Footing Inspection
02/16/2016PassTed DyeFoundation Inspection
02/19/2016PassQuinton OwensCommercial Insulation Inspection
Foundation insulation. Replace fallen insulation on section of foundation near
north end of west wall.
Inspector Comments:
02/25/2016PassQuinton OwensCommercial Footing Inspection
Interior footings in slab.Inspector Comments:
04/26/2016PassTed DyeSidewalk Inspection
06/16/2016PassTed DyeSheeting
06/16/2016PassTed DyeResidential Framing/Structure Inspection
06/21/2016FailQuinton OwensResidential Insulation Inspection
Framing items not complete: Proper fire caulking on interior walls (top & bottom
plates), fire rating around tub drains on 2nd level, draft stopping in attic not
done, and approval on holes in floor joists above bearing wall.
Insulation missing above doors. and gaps between studs to be insulated or
foamed.
Fire blocking will need to be done in floor cavities above separation walls with
insulation or framing.
Approved to drywall ceilings and walls in concealed locations for inspection.
Inspector Comments:
06/22/2016FailQuinton OwensResidential Insulation Inspection
Corrections not made to insulation as noted. Insulate around doors and gap in
back corner of 3rd unit from south on 1st floor.
Inspector Comments:
06/22/2016FailQuinton OwensCommercial Framing/Structure Inspection
South end unit party wall is missing fire rated drywall behind tub.Inspector Comments:
06/28/2016FailQuinton OwensResidential Sheetrock/Drywall Inspection
2nd floor: Fire caulking and drywall in concealed locations was completed except
in south end unit as noted above.
Approved to hang remaining pieces and tape upper level units except south end.
Inspector Comments:
6/28: Joist repairs completed as required in 2nd & 3rd units from north end.Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 16-00052
250 W 1st N - 12 Plex - Bear Building 1 - East
250 W 1st N
New Multi-Family Residential/Dormitory
Permit Status of (Expired) as of Report Date: 05/31/2019 10:10 am
Permit
Inspection
Summary
06/30/2016FailQuinton OwensCommercial Framing/Structure Inspection
6/29: Last of 1st level fire rating in concealed locations completed. Approved to
hang drywall on all 1st level units.
Still required: correction for bedroom windows to meet egress requirements (no
more than 13% of back wall can have unprotected openings), and fire rating
behind tub in 2nd floor south unit to be completed and inspected. Fire rating
needed on outside of popouts on east side.
Inspector Comments:
08/15/2016PassQuinton OwensResidential Sheetrock/Drywall Inspection
Exterior drywall for fire rating on east side pop outs.
Windows approved on east side for exterior openings based on fire separation
distance (12.9%) - allowed 13% by interpolation of IBC Table 705.8.
Furniture in bedroom to be under casement windows - sill height exceeds 44"
max allowed.
Inspector Comments:
08/26/2016PassTed DyeResidential Sheetrock/Drywall Inspection
08/30/2016FailQuinton OwensCommercial Building Final
Patch ceiling rating around sprinkler head in 3103 & 3204; Smoke detectors not
interconnected in 3204; Finish Type A unit and an accessible route from parking.
Fire rate penetration in fire riser room. Building address & unit numbers are
missing. Draft stops not inspected yet in attic.
Inspector Comments:
Approved for partial occupancy pending other final inspections.
Conditional on Type A unit is not all ready and accessible route to it from parking.
Other occupied buildings to be identified from street for building numbers
(building 1 & 2)
Inspector Comments:
09/01/2016FailQuinton OwensCommercial Building Final
Unit 3204: Smoke detectors not interconnected.Inspector Comments:
09/30/2016FailTed DyeCommercial Building Final
07/18/2017FailTed DyeCommercial Building Final
01/25/2018PassQuinton OwensCommercial Building Final
Ramp access to sidewalk is comleted with 1/48 slope shown on smart level.Inspector Comments:
Electrical Inspection Type
06/15/2016PassBret StoddardElectrical Rough-in SFR-A,R,B, MFR-A,R
08/05/2016PassBret StoddardCOM & MFR Electrical Service Inspection
08/25/2016FailBret StoddardElectrical Final Inspection SFR-B,A,R, MFR-A,R
08/29/2016PassBret StoddardElectrical Final Inspection SFR-B,A,R, MFR-A,R
Page 2 of 3
(Continued)
Permit Details Permit Number: 16-00052
250 W 1st N - 12 Plex - Bear Building 1 - East
250 W 1st N
New Multi-Family Residential/Dormitory
Permit Status of (Expired) as of Report Date: 05/31/2019 10:10 am
Permit
Inspection
Summary
Fire Inspection Type
08/23/2016PassDale PickeringFire Sprinkler Hydro
Underground flush was completed on 8/23 by Jonathon McMillan. DPInspector Comments:
08/31/2016PassBret StoddardFire Alarm Final Inspection
09/01/2016PassDale PickeringFire Department Final Inspection
Mechanical Inspection Type
06/10/2016FailDon AllenHVAC Rough-in
06/20/2016FailDon AllenHVAC Rough-in
08/29/2016PassDon AllenHVAC Final Inspection
Plumbing Inspection Type
02/24/2016PassDon AllenPlumbing Underground Inspection
good to cover the plumbing undergroundInspector Comments:
06/10/2016PassDon AllenPlumbing Rough-in
06/20/2016PassDon AllenPlumbing Water
08/26/2016PassDon AllenPlumbing Rough-in
08/29/2016PassDon AllenPlumbing Final Inspection
Good for the C/OInspector Comments:
Page 3 of 3