HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00266 - 1360 S 12 W - Motel 6Permit Inspection Summary Permit Status of (Open) as of Report Date: 05/29/2019 11:43 am Permit Details Permit Number: 16-00266 1360 S 12 W - Motel 6 1360 S 12 W Building - Commercial Permit Issued Date: Permit Inspection Statistics 40Total Inspections Completed: 28Total Inspections Passed: Inspection Pass Rate: 70.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 04/20/2017PARTPASSJoel GrayPublic Works Final Inspection Items needing addressed: 1.Swales on south and west sides not completed. (To be completed by June 1) 2.Swale in center of parking lot filled with gravel and shorter than proposed resulting in less storage volume. Resolved on site 8 ft depth to allow for rock fill.) 3.Setbacks not followed on 12th West. 4.Street sign damaged. (car slid off road) 5.Has agreement for road widening and sidewalks been signed by both parties? 6.What is black pipe on East end for? (French drain to be installed by June 1) 7.Trash enclosure detail is for 2 dumpsters not 1.( Try 1 but acknowledge possible need for 2 and will increase if necessary) 8.Gravel on North side? (May not happen) 9.Right of way needs to be deeded to City on 2000 S and 12th W. and 15 ft utility easements along perimeter of parcel. Inspector Comments: 10/11/2017PassNatalie PowellPlanning and Zoning Final Inspection Building Inspection Type 05/03/2016FailQuinton OwensCommercial Footing Inspection 05/04/2016PassQuinton OwensCommercial Footing Inspection Ufer installed in SE corner.Inspector Comments: 05/05/2016PassTed DyeFoundation Inspection West halfInspector Comments: Ufer ground rebar added inside foundation wall (ufer bar in footing ended up outside foundation wall). Inspector Comments: 05/06/2016PassQuinton OwensFoundation Inspection Inspection for East half of building foundation.Inspector Comments: 05/17/2016PassQuinton OwensCommercial Insulation Inspection Foundation insulationInspector Comments: 06/10/2016PassQuinton OwensCommercial Footing Inspection Partial footing: Slab with interior footings under corridor only. Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 16-00266 1360 S 12 W - Motel 6 1360 S 12 W Building - Commercial Permit Status of (Open) as of Report Date: 05/29/2019 11:43 am Permit Inspection Summary 06/16/2016PassTed DyeFoundation Inspection Shearwall footing/foundation on east end of building, last floor pour.Inspector Comments: 08/26/2016PassQuinton OwensCommercial Sheetrock/Drywall Inspection Pre-rock behind tubs only for rated walls.Inspector Comments: 09/22/2016FailTed DyeCommercial Framing/Structure Inspection 09/22/2016FailTed DyeSheeting Those spots that missed having the sheeting nailed to the studs is marked with green paint, some inside and some outside. Inspector Comments: 09/29/2016PassTed DyeSheeting Corrections made. OK to cover exterior Inspector Comments: 10/26/2016PassTed DyeCommercial Framing/Structure Inspection Truss and draft stop inspections only. All other framing inspection items to be inspected at a later date. Draft stops were good. Inspector Comments: 11/02/2016FailTed DyeResidential Framing/Structure Inspection In the wall framing section that failed, the measurement for the wall separating the differant flight of stairs , should have read " from the front of the tread measured vertically 42" to the top of the wall". Inspector Comments: 11/28/2016FailQuinton OwensCommercial Insulation Inspection 11/23/16: Penetrations in top & bottom plates in non-rated walls are sealed with "fire block" foam and are not fire rated as instructed previously. Only the two walls inside sleeping units require fire caulking at top and bottom plate penetrations upstairs and top plates on first floor. Exterior walls and corridor are approved for cover. Call for inspection of fire caulking. Inspector Comments: 12/12/2016PARTPASSBret StoddardCommercial Sheetrock/Drywall Inspection 12/16/2016PassQuinton OwensCommercial Sheetrock/Drywall Inspection 1st level only.Inspector Comments: Fire rate penetrations in all separation walls where they occur. Plastic pipes have intumescent fire caulk INSIDE 3/8" annular space between pipe and drywall. Inspector Comments: Self closing device required on doors to main laundry room. Inspector Comments: Fire rate PVC pipe penetrations in ceilings of storage rooms about halfway down the corridor (caulk to be INSIDE 3/8" annular space). Inspector Comments: Parking lot to be marked as soon as weather permits. Handicap parking as per IBC & A117.1-2009. Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 16-00266 1360 S 12 W - Motel 6 1360 S 12 W Building - Commercial Permit Status of (Open) as of Report Date: 05/29/2019 11:43 am Permit Inspection Summary Address numbers to be posted where easily seen from street. Inspector Comments: Exterior finishes shall be done at front entrance prior to public access. Inspector Comments: Fix smoke detector as identified with Ted on first floor. Inspector Comments: 03/30/2017FailQuinton OwensCommercial Building Final Vertical grab bars missing at water closets (required). Vertical grab bars at non-roll in showers (pending decision). Inspector Comments: Electrical Inspection Type 10/13/2016PassBret StoddardCommercial Electrical Rough-in 10/18/2016PassBret StoddardCommercial Electrical Rough-in 10/20/2016PassBret StoddardCOM & MFR Electrical Service Inspection 03/29/2017PARTPASSBret StoddardCommerical Electrical Final Inspection 03/30/2017PassBret StoddardCommerical Electrical Final Inspection Fire Inspection Type 09/21/2016FailDale PickeringFire Sprinkler Rough-in 10/18/2016PassBret StoddardFire Alarm Rough-in 03/29/2017FailBret StoddardFire Alarm Final Inspection 03/31/2017PassQuinton OwensFire Alarm Final Inspection 03/31/2017PassDale PickeringFire Sprinkler Hydro Chief David Davis inspected on 3/31/2017. Passed.Inspector Comments: 04/18/2017PassDale PickeringFire Sprinkler Rough-in 04/18/2017PassDale PickeringFire Department Final Inspection 10/05/2017PassDale PickeringFire Department Final Inspection Mechanical Inspection Type 10/06/2016PassDon AllenHVAC Rough-in There was no mechanical contractor on the job. The exhaust fans in the bathrooms and the cloths dryer vents was ran by somebody. The mechanical rough in was approved by the building official. Might have to install damper see building code Inspector Comments: 04/17/2017PassDon AllenHVAC Final Inspection Page 3 of 4 (Continued) Permit Details Permit Number: 16-00266 1360 S 12 W - Motel 6 1360 S 12 W Building - Commercial Permit Status of (Open) as of Report Date: 05/29/2019 11:43 am Permit Inspection Summary Plumbing Inspection Type 05/27/2016PassDon AllenPlumbing Water 06/07/2016PassDon AllenPlumbing Underground Inspection 06/09/2016PassDon AllenPlumbing Sewer 08/12/2016PassDon AllenPlumbing Rough-in The d w v looks good will need to see the pressure on the water lines when finished Inspector Comments: 03/29/2017PARTPASSDon AllenPlumbing Final Inspection Need to support the water need vent covers on combustion air in water heater room screws need to be taken out of the dryer duct Inspector Comments: 04/17/2017PassDon AllenPlumbing Final Inspection Inspections Required Sidewalk Inspection Commercial Building Final Public Works Final Inspection Page 4 of 4