Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS/SPECS - 19-00294 - 535 Angela Dr - Solar Install
1090 E Watertower St Ste 150 Meridian ID 83642 Phone: 1-800-955-3044 Fax: 1-877-810-2840 Electrical Plans Examiner’s Report Page 1 of 1 Date: May 17, 2019 Project Name: WEB1905-00607 SOLAR - Osorio Project Description: 9 kW Roof Top Grid Tied PV Project Address: 112 S. Riverside Dr. Horseshoe Bend APPROVED Notes: (Issues that can be resolved or verified at the time of inspections.) All electrical equipment, devices, and installations shall be governed by the 2017 National Electrical Code and local codes as they are adopted within the State of Idaho. Approval of the submitted documentation and drawings by an Electrical Plans Inspection does not alleviate the contractor or individuals from adherence to the 2017 National Electrical Code and local code requirements as they are adopted. Final approval will be based upon on-site Electrical Inspections. *** Labels in accordance with NEC 690.53 and 690.54 shall be verified by on-site electrical inspections to have the correct voltage and amperage denoted. *** *** The Point of Connection shall be verified by on-site Electrical Inspections for compliance with NEC 705.12(B)(2)(3)(b). *** Aaron Reynolds Electrical Plans Examiner Cell (208) 360-2502 aaron.reynolds@dbs.idaho.gov W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t NM T R M S P A C I N V I N V A C CO N TR A C T O R IN F O R M A T I O N DE S I G N E D BY SO L A R PH O T O V O L T A I C SY S T E M DA T E IS S U E D FO R : PE R M I T SI T E PL A N , AE R I A L VI E W ww w . b i g d o g e n e r g y . c o m PV - 2 SITE PLAN AERIAL VIEW SCALE: NTSSCALE: 1" = 30'-0" TOTAL # OF PANELS 30 ABBREVIATIONS INV MSP INVERTER MAIN SERVICE PANEL MTR METER B ig Do g Re n e w a b l e En e r g y Co n t r a c t o r Li c # 01 7 9 1 6 62 0 Ph e a s a n t Ri d g e Dr Ch u b b u c k , ID 83 2 0 2 20 8 - 2 4 2 - 3 3 5 2 T 20 8 - 2 3 2 - 5 9 3 5 F X_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4/ 2 3 / 2 0 1 9 NI C O L E OS O R I O 11 2 S RI V E R S I D E DR HO R S E S H O E BE N D , ID 83 6 2 9 20 8 - 8 6 1 - 4 8 5 2 AC DISCONNECT W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t MPPT 1 MPPT 3 _ ~ A B MODULE: SILFAB 300W Voc= 39.85 V Isc= 9.71A Vmp= 32.8 V Imp= 9.16A ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. CEC ARTICLE 690.17 ELECTRICAL EQUIPMENT CALLOUTS 5kW INVERTER UNGROUNDED SOLAREDGE SE5000H-US (240V) INVERTER 240VAC, 21A, NEMA 3R, UL LISTED, (W/ INTEGRATED DC DISCONNECT) WITH INTEGRATED GFP, W/INTEGRATED AFP SQUARE D SAFETY SWITCH, P/N 3112 600 VDC, 30A, NEMA 3R, FUSIBLE, 10,000 AIC, UL, NEMA, CSA, NOM CERTIFIED W/30A FUSES 200A MAIN SERVICE PANEL, (W/ BIDIRECTIONAL UTILITY METER) SOLADECK MODEL 0783-41 JUNCTION BOX/ROOF PENETRATION MAX FUSE 30A, 600V P320 SOLAREDGE OPTIMIZER N G N G 3 N G B 9,000W TOTAL SOLAR ARRAY 30 SILFAB 300W MODULES ARRAY 1 1 STRING OF 15 MODULES @ 5.0KW SOLAREDGE INVERTER 1 STRING OF 15 MODULES @ 5.0KW SOLAREDGE INVERTER C 3 C L1 L2 L1 L2 MPPT 2 MPPT 1 MPPT 3 _ ~ A MPPT 2 D 200A E 30A B N G N G L1L1 L2L2 30A 3 3 A 2 15 MODULES IN SERIES 1 D STRING 1 TILT: 28° AZIMUTH: 180° E ONE PER PANEL 2 15 MODULES IN SERIES 1 D STRING 1 TILT: 28° AZIMUTH: 180° E ONE PER PANEL WIRE AND CONDUIT CALLOUTS (2) #10 AWG PV/RHW-2 (1) #6 AWG BARE COPPER GND IN FREE AIR (2) #10 AWG THWN-2 (1) #10 AWG THWN-2 GND IN 1" EMT/PVC (2) #10 AWG THWN-2 (1)#10 AWG THWN-2 IN 3 4" EMT 1 3 2 3' OR LESS ELECTRICAL SINGLE LINE DIAGRAM CO N TR A C T O R IN F O R M A T I O N DE S I G N E D BY SO L A R PH O T O V O L T A I C SY S T E M DA T E IS S U E D FO R : PE R M I T SI N G L E LI N E DI A G R A M PV - 3 SCALE: NTS ELECTRICAL NOTES 1. PV ARRAYS ARE PER SINGLE LINE. 2. PV ARRAY WIRING TO JUNCTION IS #10 AWG USE 2 W/ FIELD INSTALLED MC CONNECTORS TO INTERFACE W/ MODULES. 3. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 4. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER N.E.C. 250.58. 5. GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM PROTECTION OF BARE ARMOR SHEATHED CABLE FOR ALL CONDUCTOR SIZES. 6. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. 7. CONNECTORS SHALL BE POLARIS OR EUROSTRIP IT CONNECTORS. 8. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHED CUT SHEET. 9. INVERTER IS PER SINGLE LINE. 10. AC DISCONNECT SHALL BE PER SINGLE LINE. 11. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO N.E.C. 690. 12. POLE OF PV ARRAY REFERENCED TO GROUND AT THE INVERTER IN SINGLE LINE. 13. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. 14. MAXIMUM DC VOLTAGE DROP SHALL BE 2.5% 15. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 16. ALL WORK TO COMPLY WITH NEC 2014 CODE. 17. DC ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSIBLE COMBINER BOX OR FUSIBLE DC DISCONNECT MEANS. 18. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. 19. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. 20. ARC FAULT INSTALLED AT INVERTER OR IN COMBINER BOX. 21. DC GROUND FAULT PROTECTION INTEGRATED IN INVERTER. RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/ WEEBS - MODULES ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES 690.9 (A) ww w .b i g d o g e n e r g y . c o m Bi g Do g Re n e w a b l e El e c t r i c En e r g y Co n t r a c t o r Li c # 01 7 9 1 6 62 0 Ph e a s a n t Ri d g e Dr Ch u b b u c k , ID 83 2 0 2 20 8 - 2 4 2 - 3 3 5 2 T 20 8 - 2 3 2 - 5 9 3 5 F X_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4/ 2 6 / 2 0 1 9 NI C O L E OS O R I O 11 2 S RI V E R S I D E DR HO R S E S H O E BE N D , ID 83 6 2 9 20 8 - 8 6 1 - 4 8 5 2 W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t Monocrystalline PV Module SLA-M Monocrystalline 60 Cell 300 Wp ENSURES MAXIMUM EFFICIENCY 60 of the highest efficiency, premium quality monocrystalline cells result in a maximum power rating of 300Wp. ADVANCED PERFORMANCE WARRANTY 25-year linear power performance guarantee to 82% ENHANCED PRODUCT WARRANTY 12-year product/workmanship warranty BUILT BY INDUSTRY EXPERTS With over 35 years of industry experience, Silfab’s technical team are pioneers in PV technology and are dedicated to an innovative approach that provides superior manufacturing processes including: infra-red cell sorting, glass washing, automated soldering and meticulous cell alignment. POSITIVE TOLERANCE (-0/+5W) All positive module sorting ensures maximum performance 44 PPM DEFECT RATE* Total automation ensures strict quality control during each step of the process at our certified ISO manufacturing facility. *As of December 31, 2016 LIGHT AND DURABLE Over-engineered to weather low load bearing structures up to 5400 Pa. Light-weight frame exclusively designed with wide-ranging racking compatibility and durability. PID RESISTANT Proven in accordance to IEC 62804-1 AVAILABLE IN All Black 100% MAXIMUM POWER DENSITY Silfab’s SLA-M 300 ultra-high-efficiency modules are optimized for both Residential and Commercial projects where maximum power density is preferred. 100% NORTH AMERICAN QUALITY MATTERS Silfab’s fully-automated manufacturing facility ensures precision engineering is applied at every stage. Superior reliability and performance combine to produce one of the highest quality modules with the lowest defect rate in the industry. NORTH AMERICAN CUSTOMIZED SERVICE Silfab’s 100% North American based team leverages just-in-time manufacturing to deliver unparalleled service, on-time delivery and flexible project solutions. JUST -IN- TIME P E RFO R M E RTOP BAA ARRA W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t Electrical Specifications SILFAB SLA Monocrystalline Test Conditions STC NOCT Module Power (Pmax) Wp 300 227 Maximum power voltage (Vpmax) V 32.8 29.5 Maximum power current (Ipmax) A 9.16 7.69 Open circuit voltage (Voc) V 39.85 36.9 Short circuit current (Isc) A 9.71 7.96 Module efficiency % 18.4 17.3 Maximum system voltage (VDC) V 1000 Series fuse rating A 15 Power Tolerance Wp -0/+5 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% • Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by -0/+5. Si l fa b - S L A - M - 3 0 0 - S F - 0 G - 2 0 1 8 0 2 0 1 - K • No re p r o d u c t i o n of an y ki n d is al l o w e d . Da t a an d in f o r m a t i o n is su b j e c t to mo d i f i c a t i o n s wi t h o u t no t i c e . ©S i l f a b , 20 1 8 . Temperature Ratings SILFAB SLA Monocrystalline Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.38 NOCT (± 2°C) °C 45 Operating temperature °C -40/+85 Mechanical Properties and Components SILFAB SLA Monocrystalline Module weight (± 1 kg) kg 19 Dimensions (H x L x D; ± 1mm) mm 1650 x 990 x 38 Maximum surface load (wind/snow)* N/m2 5400 Hail impact resistance ø 25 mm at 83 km/h Cells 60 - Si monocrystalline - 4 or 5 busbar - 156.75 x 156.75 mm Glass 3.2 mm high transmittance, tempered, antireflective coating Backsheet Multilayer polyester-based Frame Anodized Al Bypass diodes 3 diodes-45V/12A, IP67/IP68 Cables and connectors (See installation manual) 1200 mm ø 5.7 mm (4 mm2), MC4 compatible Certifications SILFAB SLA Monocrystalline Product ULC ORD C1703, UL 1703, IEC 61215, IEC 61730, IEC 61701, CEC listed UL Fire Rating: Type 2 (Type 1 on request) Factory ISO 9001:2008 Warranties SILFAB SLA Monocrystalline Module product warranty 12 years 25 years Linear power performance guarantee ≥ 97% end of 1 st year ≥ 90% end of 12th year ≥ 82% end of 25th year CC 4 00 7x12 (x4) Mounting Slot Grounding Hole Ø4.2 (x2) Grounding Hole Drainage (x8) 1 2 7 10 C-C Profile View 3 8 26 1 .8 1 2 0 0 ± 1 5 1 65 0 38 8 50 958 All Dimensions in mm Tolerances: ±1mm Hole tolerances: ±0.2mm Drawings not to scale 990 Third-party generated pan files from PV Evolution Labs available for download at: www.silfab.ca/downloads Warning: Read the installation and User Manual before handling, installing and operating modules. Pallet Count: 26 Container Count: 936 Silfab Solar Inc. 240 Courtneypark Drive East • Mississauga, Ontario Canada L5T 2S5 Tel +1 905-255-2501 • Fax +1 905-696-0267 info@silfab.ca • www.silfab.ca W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t MA N U FA C T U R E R SP E C SH E E T - RA I L W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t MA N U FA C T U R E R SP E C SH E E T - RA I L W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t MA N U FA C T U R E R SP E C SH E E T - RA I L W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t MA N U FA C T U R E R SP E C SH E E T - RA I L W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t I N V E R T E R S www.solaredge.us 1 2-25 S ingle Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optmizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protecton and rapid shutdown for NEC 2014 and 2017, per artcle 690.11 and 690.12 UL1741 SA cert fied, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytc capacitors Built-in module-level monitoring Outdoor and indoor installaton Optonal: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)- 3 - 3 - - - Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)3 3 3 3 3 3 3 Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Contnuous Output Current 208V - 16 - 24 - - - A Maximum Contnuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 A Utlity Monitoring, Islanding Protecton, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - - Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - - Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protecton Yes Ground-Fault Isolaton Detecton 600k Sensitvity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nightme Power Consumpton < 2.5 W ADDITIONAL FEATURES Supported Communica ton Interfaces RS485, Ethernet, ZigBee (optonal), Cellular (optonal) Revenue Grade Data, ANSI C12.20 Optonal(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatc Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connecton Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convecton Natural convecton Operatng Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C opton)(4) ˚F / ˚C Protecton Ra tng NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional setngs please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2 (3) For power de-ratng informaton refer to: htps://www.solaredge.com/sites/default/files/se-temperature-deratng-note-na.pdf (4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t P O W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 / P505 Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitgates all types of module mismatch losses, from manufacturing tolerance to partal shading Flexible system design for maximum space utliza ton Fast installaton with a single bolt Next generat on maintenance with module-level monitoring Compliant with arc fault protecton and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t OPTIMIZER MODEL (typical module compatbility) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) P505 (for higher current modules) INPUT Rated Input DC Power(1) 320 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature)48 60 80 125 83 Vdc MPPT Opera tng Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optmizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatble inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(2) Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ſt Operatng Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protecton Ratng IP68 / NEMA6P Rela tve Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge SolarEdge Power Optimizer Module Add-On for North America P320 / P370 / P400 / P405 / P505 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)(4) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optmizers) P320, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optmizers)25 25 50(5) Maximum Power per String 5700 (6000 with SE7600H-US, SE10000H-US) 5250 6000 12750 W Parallel Strings of Different Lengths or Orientatons Yes © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice. (3) For detailed string sizing informaton refer to: htp://www.solaredge.com/sites/default/files/string_sizing_na.pdf. (4) It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string. (5) A string with more than 30 optmizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement W E B 1 9 0 5 - 0 0 6 0 7 0 5 / 1 7 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t