Loading...
HomeMy WebLinkAboutCALC AREA Project Name : SOUTH FORK VILLA Drawing No. : 18-230 Project Location: 425 S 3RD W City: SUGAR CITY, ID 83448 CALCULATION SUMMARY Design Areas Design Area Name Min. Density Area of Application Occupancy Calculated Heads Min. Pressure Hose Streams Total Water Pressure @ Source Margin To Source (gpm/ft²)(ft²)#(psi)(gpm)(gpm)(psi)(psi) Min. Flow (gpm) Calc. Mode (Model) 1 LIGHT 428 168.2 Required 56.9 0.055 22 3 100 12.914.4Demand (HW) Date 8/7/2018 Page 1 Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 1 2ND FLOOR LIGHT 0.055 428 400 3 0 100 168.2 56.9 Wet 25.5 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 07/23/2018 ON SITE SRC Project Name : SOUTH FORK VILLA Contract No. : 18-230 Project Location: 425 S 3RD W City: SUGAR CITY, ID 83448 Date: 8/1/2018 Name of Contractor: PHOENIX FIRE PROTECTION Address: 4130 AIRPORT RD Phone Number: (208) 468-9115 Name of Designer: DENNIS APPLE Authority Having Jurisdiction: STATE FIRE MARSHAL City: NAMPA, ID 83687 E-mail: dennis@phoenixfp.com Job Information Contractor Information Notes Date 8/7/2018 Page 2Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Job : SOUTH FORK VILLA Diagram for Design Area : 1 (Optimized Hydraulic Simplified) Node Labels: Pipe Labels: Off Off Date 8/7/2018 Page 3Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Job : SOUTH FORK VILLA Hydraulic Analysis for : 1 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : SRC Flow (gpm)Pressure (psi) 0 70 1250 60 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis SRC 70 60 1250 70 168.2 56.9 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 68.2 0 0 68.2 Required Margin of Safety (psi) SRC - Pressure (psi) SRC - Flow (gpm) Demand w/o System Pump(s) 0 56.9 68.2 N/A Sprinklers Other Date 8/7/2018 Page 4Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Job : SOUTH FORK VILLA Hydraulic Analysis for : 1 Date 8/7/2018 Page 5 Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Job : SOUTH FORK VILLA Hydraulic Analysis for : 1 Pressure (psi)Label Graph Labels Flow (gpm) Values Description 0S1 70Supply point #1 - Static 1250S2 60Supply point #2 - Residual 0D1 10.4Elevation Pressure 68.2D2 56.9System Demand 168.2D3 56.9System Demand + Add.Out.Hose Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 78Supply69.9 12.9 168.2 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required Calculated Head Type S101 5.8 0.05 20 14.4 0.056 15.122.6400Overhead Sprinkler S102 5.8 0.05 20 14.4 0.055 14.422400Overhead Sprinkler S103 5.8 0.05 20 14.4 0.059 16.723.7400Overhead Sprinkler Date 8/7/2018 Page 6Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Job : SOUTH FORK VILLA Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm S102 19 Overhead Sprinkler HEAD 5.8 Open 22 2 400 0.055 14.4 -10.4 14.4 20 S101 19 Overhead Sprinkler HEAD 5.8 Open 22.6 2.6 400 0.056 15.1 -10.4 14.4 20 S103 19 Overhead Sprinkler HEAD 5.8 Open 23.7 3.7 400 0.059 16.7 -10.4 14.4 20 76 19.5 Node NODE 16.2 -10.6 03 19.5 Node NODE 19 -10.6 07 19.5 Node NODE 19.5 -10.6 73-O 3.76 Node NODE 41.5 -3.8 73-I 2.15 Node NODE 48.1 -3.1 74 1 Node NODE 49 -2.6 SRC -5 Supply SUPPLY -68.2 56.9 0 Date 8/7/2018 Page 7Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Hydraulic CalculationsJob : SOUTH FORK VILLA PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: S102 76 19 19.5 5.8 22 22 1 1.101 1x(BM.Tee-Run)=1 1x(BM.Tee-Br)=5 1x(BM.90)=5 14.04 11 25.04 150 0.0809 14.4 -0.2 2 76 07 19.5 19.5 22.6 44.6 1 1.101 1x(BM.Tee-Br)=5 6.09 5 11.09 150 0.2988 16.2 0 3.3 07 73-O 19.5 3.76 23.7 68.2 1.25 1.394 1x(coupling)=1.59 3x(BM.90)=18 3x(BM.Tee-Br)=18 35.07 37.59 72.66 150 0.2085 19.5 6.8 15.1 73-O 73-I 3.76 2.15 0 68.2 1.25 0 1.61 0 1.61 0 3.6332 41.5 0.7 5.9 Ames2000B *** 73-I 74 2.15 1 0 68.2 1.25 1.394 1x(BM.Coupl)=1 1.15 1 2.15 150 0.2085 48.1 0.5 0.4 74 SRC 1 -5 0 68.2 2 2.003 3x(BM.90)=30 118.28 30 148.28 150 0.0357 49 2.6 5.3 SRC 56.9 2Path No: S101 76 19 19.5 5.8 22.6 22.6 1 1.101 2x(BM.Tee-Br)=10 5.42 10 15.42 150 0.0847 15.1 -0.2 1.3 76 16.2 3Path No: S103 03 19 19.5 5.8 23.7 23.7 1 1.101 2x(BM.90)=10 17.5 10 27.5 150 0.0926 16.7 -0.2 2.5 03 07 19.5 19.5 0 23.7 1.25 1.394 4x(BM.Tee-Run)=4 13.98 4 17.98 150 0.0294 19 0 0.5 07 19.5 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. *** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. * Maximum Velocity of 15.02 ft/s occurs in the following pipe(s): (07-76) Date 8/7/2018 Page 8Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg Device GraphsJob : SOUTH FORK VILLA Date 8/7/2018 Page 9Copyright © 2002-2012 Tyco Fire Protection Products File: D:\Dropbox (Phoenix Fire)\Phoenix Fire - Design\Current Jobs\2018\18-230 Sugar 4 Plexes - South Fork Villa - Sugar City\18-230 FP.dwg