Loading...
HomeMy WebLinkAboutRA3331 4.4K HSWReliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 B u l l e t i n 0 3 3 R e v . C Bulletin 033 Rev. C Model F1 RES LL Residential Sprinklers Types: 1. F1 Res 30 LL Pendent 2. F1 Res 30 LL Recessed Pendent/F2 3. F1 Res 30 LL Recessed Pendent/FP 4. F1 Res 49 LL Pendent 5. F1 Res 49 LL Recessed Pendent/F1 6. F1 Res 49 LL Recessed Pendent/FP 7. F1 Res 58 LL Pendent 8. F1 Res 58 LL Recessed Pendent/F1 9. F1 Res 58 LL Recessed Pendent/FP 10. F1 Res 30 LL CCP Pendent 11. F1 Res 49 LL CCP Pendent 12. F1 Res 58 LL CCP Pendent 13. F1 Res 44 LL HSW 14. F1 Res 44 LL Recessed HSW/F2 15. F1 Res 58 LL HSW 16. F1 Res 58 LL HSW Recessed HSW/F2 17. F1 Res 44 LL SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) for Safety to ANSI/ UL1626. 2. Certified by Underwriters Laboratories, Inc. and Under- writers Laboratories of Canada for Health Effects to NSF/ ANSI Standard 61 Annex G (Less than 0.25% Lead Con- tent.) Additional Bulletins applicable to all F1RES LL Sprinklers • Wall Wetting - Bulletin 007 • Design and Installation - Bulletin 140 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 LL & 58 LL Pendent Sprinklers Other patents pending. Product Description Model F1 Res LL Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high F1 Res 49 LL & 58 LL Recessed Pendent/F1 F1 Res 49 LL & 58 LL Recessed Pendent / F1 F1 Res 30 LL Recessed Pendent/F2 F1 Res 44 LL & 58 LL Recessed HSW/F2 F1 Res 30 LL, 49 LL & 58 LL CCP Pendent F1 Res 44 LL SWC sensitivity glass-bulb and low profile decorative design. The F1 Res LL Horizontal Sidewall sprinklers (Figs. 5, & 6) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in resi- dential fire protection design. The low flow F1 Res LL sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R½) • K-Factor: 3.0 (Actual) - F1 Res 30 LL Pendent Sprinkler 4.9 (Actual) - F1 Res 49 LL Pendent Sprinkler 5.8 (Actual) - F1 Res 58 LL Pendent & HSW Sprinkler 4.4 (Actual) - F1 Res 44 LL HSW Sprinkler Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. F1 Res 30 LL, 49 LL & 58 LL Pendent F1 Res 44 LL & 58 LL HSW 2. Application Model F1 Res LL sprinklers are cULus Listed in accor- dance with UL 1626 for installation in accordance with NFPA 13, NFPA 13R, and NFPA 13D. Sprinkler systems using Model F1 Res LL sprinklers must be hydraulically designed to provide at least the flow identified in the Tech- nical Data tables in this bulletin. For NFPA 13 installations, the flow per sprinkler must be the greater of: (1) the flow listed in the applicable Technical Data table and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For cover- age area dimensions less than those listed in the Technical Data tables, use the minimum required flow for the next larger max. coverage area listed. Installation Models F1 Res LL sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res LL sprinklers. Use of any other recessed escutch- eon will void all approvals and warranties. For installing Model F1 Res LL Pendent sprinklers use only the Model D or W2 sprinkler Wrench; for installing Models F1 Res LL Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 LL Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those speci- fied may damage these sprinklers. Install F1 Res 44 LL with a ceiling to deflector distance of 4” - 12”. Flow arrow on deflector must point away from near wall and “Top” mark- ing must face ceiling. Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fitting to ceiling Inch (mm) F1 3/4 (19.0)Min.=3/4” (19.1) Max.=11/2” (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.=15/16” (23.8) Max.=11/2” (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 LL & 58 LL Recessed Pendent Sprinkler • Model F1 Res 30 LL, 49 LL & 58 LL Pendent • Model F1 Res 30 LL Recessed Pendent / F2 • Model F1 Res 49 LL & 58 LL Recessed Pendent / F1 Fig. 1 Fig. 2 F1 escutcheon, 3/4” (19mm) adjustment 3. Technical Data: F1Res 30 LL Pendent and Recessed Pendent (SIN RA3311) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp.Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2)175 (12)155 175 68 79 100 38 3.0 (43.2)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)8 (30.3)7.0 (0.48)8 (30.3)7.0 (0.48)Smooth Ceilings 1¼ to 4 (31.7 to 102) using F2 escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1¼ to 1¾ (31.7 to 44.4) using F2 escutcheon 8 (2.4)14 x 14 (4.3 x 4.3)14 (4.3)10 (37.8)11 (0.76)10 (37.8)11 (0.76) 16 x 16 (4.9 x 4.9)16 (4.9)13 (49)18.8 (1.3)13 (49)18.8 (1.3) Technical Data: F1Res 49 LL Pendent and Recessed Pendent (SIN RA3316) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)7/16” (11)175 (12)155 175 68 79 100 150 38 66 4.9 (70.6)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49)7.0 (0.48)13 (49)7.0 (0.48)Smooth Ceilings 1¼ to 4 (31.7 to 102) using F2 escutcheon. 1 to 4 (25.4 to 102) using F1 escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1¼ to 1¾ (31.7 to 44.4) using F2 escutcheon, 1 to 1¾ (25.4 to 44.4) using F1 escutcheon 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)13 (49)7.0 (0.48)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)16 (4.9)13 (49)7.0 (0.48)13 (49)7.0 (0.48) 18 x 18 (5.5 x 5.5)18 (5.5)17 (64.3)12 (0.83)17 (64.3)12 (0.83) 20 x 20 (6.1 x 6.1)20 (6.1)20 (75.7)16.7 (1.14)20 (75.7)16.7 (114) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)15 (57)9.4 (0.65)15 (57)9.4 (0.65)Smooth Ceilings 4 to 8 (100 to 203) using F2 escutcheon. 4 to 8 (100 to 203) using F1 escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 4¼ to 8 (108 to 203) using F2 escutcheon, 4 to 8 (100 to 203) using F1 escutcheon 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (60.5)10.6 (0.73)16 (60,5)10.6 (0.73) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.3)12.0 (0.83)17 (64.3)12.0 (0.83) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)15.0 (1.0)19 (72)15.0 (1.0) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83.2)20.2 (1.4)22 (83.2)20.2 (1.4) FP push-on/thread-off escutcheon 4. • Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent • Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent / FP Fig. 3 Fig. 4 Technical Data: F1Res 58 LL Pendent and Recessed Pendent (SIN RA3313) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp.Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)½” (13)175 (12)155 175 68 79 100 150 38 66 5.8 (83.5)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (61)7.6 (0.53)16 (61)7.6 (0.53)Smooth Ceilings 1¼ to 4 (31.7 to 102) using F2 escutcheon. 1 to 4 (25.4 to 102) using F1 escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1¼ to 1¾ (31.7 to 44.4) using F2 escutcheon, 1 to 1¾ (25.4 to 44.4) using F1 escutcheon 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (61)7.6 (0.53)16 (61)7.6 (0.53) 16 x 16 (4.9 x 4.9)16 (4.9)16 (61)7.6 (0.53)16 (61)7.6 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)10.8 (0.75)19 (72)10.8 (0,75) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83,3)14.4 (1.0)22 (83.3)14.4 (1.0) 5. Technical Data: F1Res 30 LL CCP Pendent and Recessed Pendent/FP (SIN RA3311) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2)175 (12)135 57 100 38 3.0 (43.2)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)8 (30.3)7.0 (0.48)Smooth Ceilings ½ to 1 (13 to 25.4) using CCP. ½ to 1 (13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1 (13 to 25.4) using CCP. ½ to 1 (13 to 25.4) using FP escutcheon. 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)11 (37.8)13.4 (0.92) Technical Data: F1Res 49 LL CCP Pendent and Recessed Pendent/FP (SIN RA3316) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)7/16” (11)175 (12)135 57 100 38 4.9 (70.6)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49)7.0 (0.48) Smooth Ceilings ½ to 1 (13 to 25.4) using CCP. ½ to 1 (13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1 (13 to 25.4) using CCP. ½ to 1 (13 to 25.4) using FP escutcheon. 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)16 (4.9)14 (53)8.2 (0.56) 18 x 18 (5.5 x 5.5)18 (5.5)18 (68.1)13.5 (0.93) 20 x 20 (6.1 x 6.1)20 (6.1)20 (75.7)16.7 (1.14) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1Res 58 LL CCP Pendent and Recessed Pendent/FP (SIN RA3313) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)1/2” (13)175 (12)135 57 100 38 5.8 (83.5)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (61)7.6 (0.53) Smooth Ceilings ½ to 1 (13 to 25.4) using CCP. ½ to 1 (13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1 (13 to 25.4) using CCP. ½ to 1 (13 to 25.4) using FP escutcheon. 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (61)7.6 (0.53) 16 x 16 (4.9 x 4.9)16 (4.9)16 (61)7.6 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83.3)14.4 (1.0) 6. • Model F1 Res 44 LL & 58 LL HSW • Model F1 Res 44 LL & 58 LL Recessed HSW/F2 F2 escutcheon, 1/2” (13mm) adjustment Technical Data: F1Res 44 LL HSW & HSW/F2 (SIN RA3331) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8” (10)175 (12)155 175 68 79 100 150 38 66 4.4 (63)2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 1/2 (13)3/16 - 11/16 (4.7 - 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)12 (45.4)7.5 (0.52)12 (45.4)7.5 (0.52) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)14 (53.0)10.2 (0.71)14 (53.0)10.2 (0.71) 16 x 16 (4.9 x 4,9)16 (4.9)16 (60.6)13.3 (0.92)16 (60.6)13.3 (0.92) 16 x 18 (4.9 x 5.5)16 (4.9)18 (68.1)16.8 (0.53)18 (68.1)16.8 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72.0)18.7 (1.29)19 (72.0)18.7 (1.29) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89)23 (87.1)27.4 (1.89) 12 x 12 (3.6 x 3.6)12 (3.6)14 (53.0)10.2 (0.71)14 (53.0)10.2 (0.71) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14 (4.3 x 4.3)14 (4.3)16 (60.6)13.3 (0.92)16 (60.6)13.3 (0.92) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.4)15.0 (1.04)17 (64.4)15.0 (1.04) 16 x 18 (4.9 x 5.5)16 (4.9)20 (75.7)20.7 (1.43)20 (75.7)20.7 (1.43) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89)23 (87.1)27.4 (1.89) Fig. 5 7. Technical Data: F1Res 44 LL SWC (SIN RA3331) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Cover Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8” (10)175 (12)135 57 100 38 4.4 (63)2.45 (62) • Model F1 Res 44 LL SWC Fig. 6 Technical Data: F1Res 58 LL HSW & HSW/F2 (SIN RA3333) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)1/2” (13)175 (12)155 175 68 79 100 150 38 66 5.8 (83.5)2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (60.6)7.6 (0.53)16 (60.6)7.6 (0.53) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)18 (68.2)9.7 (0.69)18 (68.2)9.7 (0.69) 16 x 16 (4.9 x 4.9)16 (4.9)21 (79.5)13.2 (0.91)21 (79.5)13.2 (0.91) 16 x 18 (4.9 x 5.5)16 (4.9)25 (94.7)18.6 (1.28)25 (94.7)18.6 (1.28) 16 x 20 (4.9 x 6.1)16 (4.9)29 (109.8)25.0 (1.73)29 (109.8)25.0 (1.73) 12 x 12 (3.6 x 3.6)12 (3.6)22 (83.3)14.4 (1.0)22 (83.3)14.4 (1.0) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14 (4.3 x 4.3)14 (4.3)22 (83.3)14.4 (1.0)22 (83.3)14.4 (1.0) 16 x 16 (4.9 x 4.9)16 (4.9)26 (98.4)20.1 (1.39)26 (98.4)20.1 (1.39) 16 x 18 (4.9 x 5.5)16 (4.9)31 (117.4)28.6 (1.97)31 (117.4)28.6 (1.97) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49.2)8.7 (0.60) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)14 (53.0)10.2 (0.71) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.3)15.0 (1.1) 16 x 18 (4.9 x 5.5)16 (4.9)19 (71.8)18.7 (1.13) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89) 12 x 12 (3.6 x 3.6)12 (3.6)14 (52.9)10.2 (0.71) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14 (4.3 x 4.3)14 (4.3)15 (56.7)11.7 (0.81) 16 x 16 (4.9 x 4.9)16 (4.9)18 (68.1)16.8 (1.16) 16 x 18 (4.9 x 5.5)16 (4.9)20 (75.6)20.7 (1.43) Maintenance Model F1 Res 30 LL, 49 LL, F1 Res 58 LL and F1 Res 44 LL Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model F1 Res 30 LL, 49 LL & 58 LL Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guide- lines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and de- flector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome-plat- ed] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 49 LL & 58 LL Recessed Pendent/F1 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. List- ed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and de- flector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed es- cutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Mod- el F1)] [of push-on and thread off design with ½” adjust- ment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F1] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP] SIN RA3311, RA3316 & RA3313 (Bulletin 033). 8. Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 9. Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent (Concealed) Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Wa- ter seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of 155°F (68°C). Cover plate as- sembly shall consist of a brass cover plate and copper al- loy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Col- or– specify]. ]. Concealed pendent sprinklers shall be Reli- able Model F1 Res 30 LL, 49 LL & 58 LL CCP, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 44 LL Horizontal Sidewall Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal side- wall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. List- ed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed un- der sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential hori- zontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL, SIN RA3331 (Bulletin 033). Model F1 Res 44 LL Recessed Horizontal Sidewall Sprinkler Specifications Use description for the Model F1 Res 44 horizontal side- wall sprinkler with the following modifications: Replace “horizontal sidewall sprinkler” with “recessed horizontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL/F2, SIN RA3331 (Bulletin 033). Standard Finishes Sprinkler F1, F2, FP Escutcheons Cover Plates Bronze Chrome Plated White and Black Polyester Coated Brass Bright Chrome Plated White Painted White Painted Chrome Special Application Finishes Sprinkler F1, F2, Escutcheons Cover Plates Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03/17 P/N 9999970411 • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years.