HomeMy WebLinkAboutPLANS 1 - 17-00123 - 555 W Mikan Dr - Eden Apartments Bldg 4 - 42 UnitsMEGALUG Retaining Flange Finished Floor 51ab Q) 2" Clec MEGALUG Retaining Flange Concrete Thrust Block/ r ace Protect Fittincl W/ Vi R IS "F STUB -IN DETAIL NTS een 12" min W N S �rrora E SCALE - 1" = 40'-0" 40 30 20 10 0 20 40 80 qlilwl-�R!Nj 1�►� NS moi! 1 - ALL UNDERGROUND FIRE MAIN PIPING TO BE IN5TALLED IN ACCORDANCE WITH NFPA #13,24 2 - 5GOPE OF WORK TO COMMENCE A5 INDICATED ON 51TE PLAN 3 - UNDERGROUND PIPING 5HALL BE C-900 WITH CLA55 50 DUCTILE IRON THROUGH FLOOR 5LAB 4 - CHANGE5 IN DIRECTION OF PIPING TO BE MADE BY THE U5E OF MECHANICAL JOINT FITTINGS 5 - THRU5T RE5TRAINT5 TO BE PROVIDED AT ALL TURNS AND ENDS OF MAINS PER NFPA 113 (o - FLU5HING AND TE5TING OF UNDERGROUND PIPING TO BE PERFORMED A5 PER NFPA 113 I - NUTS, BOLTS, RODS, WASHERS, CLAMPS, AND OTHER RE5TRAINING DEVICE5 ON ALL UNDERGROUND PIPING ARE TO BE COATED WITH BITUMINOUS OR OTHER APPROVED CORROSION RETARDING MATERIAL S - A5 PER NFPA 13 10.4 THE DEPTH OF COVER FOR BURIED PIPE, A5 DETERMINED BY THE STATE OF IDAHO FIRE MAR5HAL, 5HALL NOT BE LE55 THEN 12", TO THE TOP OF THE PIPE, BELOW THE FINI5HED GRADE. 9 - ALL BURIED U.G. PIPING TO MEET THE REQUIREMENTS OF NFPA 13 10.4.1 THRU 10.4.6, AND LOCAL AUTHORITIE5. 10 - ALL UNDERGROUND FIRE MAIN5 TO HAVE TRACER WIRE 1 1/4" TO SYSTEM 00 RISER MANIFOLD W/: (1) DRAIN AND TEST Q 4 t 9 � (2) FLOW SWITCH 1 (3) PRESSURE GAUGE i TO (4) SIGNS AS REQUIRED DRAIN RISER MANIFOLD DETAIL NTS NOTE 1) FLOW SWITCH TO BE INTEI;RFACED WITH BUILDING SMOKE OR ALARM DEVICES. DEVICES AND INSTALLATION TO BE PROVIDED BY OTHERS. NOT IN PHOENIX FIRE CONTRACT 2) ALARM DEVISES SHALL BE CAPABLE OF PRODUCING AN AUDIBLE ALARM THROUGHOUT PREMI5E5.(BY OTHERS) 3) PHOENIX POINT OF CONNECTION TO BE ON DISCHARGE SIDE OF BACKFLOW PREVENTER "Eno eax `.xJ + 4� RISER DETAIL ,A 3/8" = 1' - 0" O❑ 11-011 0 ALL ELECTRICAL WIRING BY OTHERS MlAfNWIF/ "421� 3 • PROJECT LOCATION FLOWING: 1400 epm RE5IDUAL: 62 STATIC: 83 DATE: 02-05-2010 LOCATION: ON 51TE TE5TED E3Y:PHOENIX FIRE FIR51 FLANGE ASOvE FINISHED FLOOR, ALL UNDERGROUND DONE BY OTHERS. SNOUJN FOR NYDRAULIC PURPOSES ONLY Cc�INL I=:7_\MNL [601=� (DARE PROTECTION SYSTEM TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODES, STATE AND LOCAL FIRE MARSHALS REQUIREMENTS, NFPA 13R, 2016 EDITION. Q)ALL ELECTRICAL WIRING OF FIRE PROTECTION SYSTEM AND COMPONENTS TO BE PERFORMED BY OTHER TRADE DIVISIONS. 0 ALL PAINTING OF FIRE PROTECTION PIPING AND RELATED COMPONENTS TO BE PERFORMED BY OTHER TRADE DIVISIONS. ®ALL INSULATING OF FIRE PROTECTION PIPING AND RELATED COMPONENTS TO BE PERFORMED BY OTHER TRADE DIVISIONS. ® SPRINKLER PIPING TO BE HUNG AS PER NFPA 13R. ©PIPING LAID ON OPEN JOISTS OR RAFTERS SHALL BE SUPPORTED IN A MANNER THAT PREVENTS LATREAL MOVEMENT. Q STEEL PIPING IN UNFINISHED BASEMENT CONFORMING TO NFPA. ® ALL WELDING TO BE DONE BY A CERTIFIED WELDER IN A FABRICATION SHOP PER NFPA STANDARDS. SPRINKLER PIPING SHALL BE SUPPORTED IN A MANNER THAT PREVENTS MOVEMENT OF PIPING UPON SPRINKLER OPERATION to ALL SPRINKLER FITTINGS SHALL MEET OR EXCEED THE REQUIREMENTS OF NFPA 13 TABLE 6.4.1. &ALL SPRINKLER PIPING SHALL CONFORM TO NFPA 13 TABLE 6.3.1.1 STANDARDS AND LOCAL REQUIREMENTS. 12 SPARE SPRINKLER CABINET AND WRENCH TO BE FURNISHED PER NFPA 13. I14 ROOM OCCUPANCY AND CEILING HEIGHT SHOWN AS: ROOM NAME DOMESTIC MATERIAL NOT REQUIRED. 10-0 ELEVATION OF PIPE SHOWN AS [0-0] IS FROM ABOVE FINISHED FLOOR FLOOR AND ELEVATIONS SHOWN AS [0-0 bts] ARE FROM BOTTOM OF TOP OF STRUCTURE DOWN. is PIPING: CPVC PIPING CONFORMING TO NFPA 13, ASTM F442 SPRINKLERS ARE NOT REQUIRED IN ATTICS PENTHOUSE EQUIPMENT ROOM, ELEVATOR MACHINE ROOM AND SHAFTS CRAWL SPACES AND OTHER CONCEALED SPACE NOT USED OR INTENDED FOR LIVING PURPOSES PER NFPA 13R 8.3.5 la ON SYSTEMS WHERE THE PRESSURE AT THE SPRINKLER EXCEEDS 100 P.S.I., BRANCH LINES SUPPORTING SPRINKLERS IN A PENDENT POSITION BELOW A CEILING SHALL BE SUPPORTED BY A HANGER THAT PREVENTS UPWARD MOVEMENT OF THE PIPE. AND THE UNSUPPORTED LENGTH OF PIPE BETWEEN THE HANGER AND END SPRINKLER IN A PENDENT POSITION SHALL NOT BE GREATER THAN 12" NFPA 13 9.2.3.4.3.1 & 2, AND BRANCH LINES SUPPORTING PENDENT SPRINKLERS BELOW CEILING SHALL NOT HAVE UNSUPPORTED ARM OVERS THAT EXCEED 12". AS PER NFPA 13 9.2.3.5.2.1. is PER NFPA 13D 8.2.5.7 SHADOW AREAS SHALL BE PERMITTED AS LONG AS THE DRY AREA DOES NOT EXCEED 15 SQ FT. 11-22E EDEN ,APARTMENT5 5PRINKLER 5CHEDULE 4 LEGEND ISYMBOLI ® RISER KEYED NOTES RESP. I 0 4" C900 I FINISH 1A 4" COPPER PIPING THROUGH FLOOR ® 02 SLEEVE AT FLOOR W/ 4" CLEAR QR 5.6 I" SPACE AROUND PIPE CHROME 03 SUPPLY SIDE PSI GAUGE b ® 11/4" AMES 20008 DOUBLE CHECK BACKFLOW PREVENTER QR 5l0 1/2" WITH 11/4" CONTROL VALVES SUPERVISED OPEN - CHROME N/A TO BE INSTALLED BY OTHERS. 05 11/4" RISER MANIFOLD 13D/13R- SEE DETAIL QR © 1" TEST AND DRAIN LINE TO BE DRAINED OUTSIDE WHITE 0 11/4" SCH 40 BLACK STEEL PIPE 41-011 ® 11/4" X V THIRD 90 Ell �9 1" THIRD X SLIP ADAPTOR r' SYSTEM HEAD CABINET WITH MIN, 6 SPARE HEADS 4 WRENCH(E5) PROVIDED 11 SPARE HEAD BOX l 6 HEAD5 ) O❑ 11-011 0 ALL ELECTRICAL WIRING BY OTHERS MlAfNWIF/ "421� 3 • PROJECT LOCATION FLOWING: 1400 epm RE5IDUAL: 62 STATIC: 83 DATE: 02-05-2010 LOCATION: ON 51TE TE5TED E3Y:PHOENIX FIRE FIR51 FLANGE ASOvE FINISHED FLOOR, ALL UNDERGROUND DONE BY OTHERS. SNOUJN FOR NYDRAULIC PURPOSES ONLY Cc�INL I=:7_\MNL [601=� (DARE PROTECTION SYSTEM TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODES, STATE AND LOCAL FIRE MARSHALS REQUIREMENTS, NFPA 13R, 2016 EDITION. Q)ALL ELECTRICAL WIRING OF FIRE PROTECTION SYSTEM AND COMPONENTS TO BE PERFORMED BY OTHER TRADE DIVISIONS. 0 ALL PAINTING OF FIRE PROTECTION PIPING AND RELATED COMPONENTS TO BE PERFORMED BY OTHER TRADE DIVISIONS. ®ALL INSULATING OF FIRE PROTECTION PIPING AND RELATED COMPONENTS TO BE PERFORMED BY OTHER TRADE DIVISIONS. ® SPRINKLER PIPING TO BE HUNG AS PER NFPA 13R. ©PIPING LAID ON OPEN JOISTS OR RAFTERS SHALL BE SUPPORTED IN A MANNER THAT PREVENTS LATREAL MOVEMENT. Q STEEL PIPING IN UNFINISHED BASEMENT CONFORMING TO NFPA. ® ALL WELDING TO BE DONE BY A CERTIFIED WELDER IN A FABRICATION SHOP PER NFPA STANDARDS. SPRINKLER PIPING SHALL BE SUPPORTED IN A MANNER THAT PREVENTS MOVEMENT OF PIPING UPON SPRINKLER OPERATION to ALL SPRINKLER FITTINGS SHALL MEET OR EXCEED THE REQUIREMENTS OF NFPA 13 TABLE 6.4.1. &ALL SPRINKLER PIPING SHALL CONFORM TO NFPA 13 TABLE 6.3.1.1 STANDARDS AND LOCAL REQUIREMENTS. 12 SPARE SPRINKLER CABINET AND WRENCH TO BE FURNISHED PER NFPA 13. I14 ROOM OCCUPANCY AND CEILING HEIGHT SHOWN AS: ROOM NAME DOMESTIC MATERIAL NOT REQUIRED. 10-0 ELEVATION OF PIPE SHOWN AS [0-0] IS FROM ABOVE FINISHED FLOOR FLOOR AND ELEVATIONS SHOWN AS [0-0 bts] ARE FROM BOTTOM OF TOP OF STRUCTURE DOWN. is PIPING: CPVC PIPING CONFORMING TO NFPA 13, ASTM F442 SPRINKLERS ARE NOT REQUIRED IN ATTICS PENTHOUSE EQUIPMENT ROOM, ELEVATOR MACHINE ROOM AND SHAFTS CRAWL SPACES AND OTHER CONCEALED SPACE NOT USED OR INTENDED FOR LIVING PURPOSES PER NFPA 13R 8.3.5 la ON SYSTEMS WHERE THE PRESSURE AT THE SPRINKLER EXCEEDS 100 P.S.I., BRANCH LINES SUPPORTING SPRINKLERS IN A PENDENT POSITION BELOW A CEILING SHALL BE SUPPORTED BY A HANGER THAT PREVENTS UPWARD MOVEMENT OF THE PIPE. AND THE UNSUPPORTED LENGTH OF PIPE BETWEEN THE HANGER AND END SPRINKLER IN A PENDENT POSITION SHALL NOT BE GREATER THAN 12" NFPA 13 9.2.3.4.3.1 & 2, AND BRANCH LINES SUPPORTING PENDENT SPRINKLERS BELOW CEILING SHALL NOT HAVE UNSUPPORTED ARM OVERS THAT EXCEED 12". AS PER NFPA 13 9.2.3.5.2.1. is PER NFPA 13D 8.2.5.7 SHADOW AREAS SHALL BE PERMITTED AS LONG AS THE DRY AREA DOES NOT EXCEED 15 SQ FT. 11-22E EDEN ,APARTMENT5 5PRINKLER 5CHEDULE 4 LEGEND ISYMBOLI SIN I SPRINKLER DESCRIPTION RESP. I K -FAG NPT TEMP, I FINISH ESCUTCHEON QTY. 9 GI -5635 GLOBE SSP QR 5.6 I" 155 CHROME RECESSED 28 b GI -5641 GLOBE SSU QR 5l0 1/2" 155 CHROME N/A 24 GL4910 GLOBE SSU QR 4.9 1/2" 155 WHITE RECESSED 212 HEAD CABINET WITH MIN, 6 SPARE HEADS 4 WRENCH(E5) PROVIDED TOTAL COUNT THIS PROJECT 324 a PILOi►Z Poo ppolOguOn J 4130 AIRPORT ROAD NAMPA, IDAHO 83687 PHONE: (208)468-91 15 FAX: (208) 461-9117 ID. LIC. F. P. S. C. #108 ID.PUBLIC WORKS LIC. #16630-A-4(13930) UTAH LIC. # 6579958-5501 5370 OREGON LIC. # 181692 WYOMING ID # 2008-000553828 WASHINGTON LIC. # PHOENFP911 KL JOB NAME: 17-228 EDEN APARTMENTS ADDRESS: 950 MIKAN DRIVE REXBURG, IDAHO 03440 DRAWN EY : DAMION 5NODGRA55 CHECKED 5Y: TRENT BICE NICET # 101524 DATE : MARGH, 2010 CODE5: NFPA 13R, 2016 I5C 2012 OCCUPANCY GLASS: R-2 GON5TRUGTION TYPE: V-5 5QUARE FOOTAGE : 12,131 NUMBER OF FLOOR5 : 3 42 =PLX 51TE PLAN SGALE : A5 NOTED ON PLANS NOTICE IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE HEAT ADEQUATE TO PREVENT FREEZING THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND ALSO IN ENCLOSURES FOR DRY PIP, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO THE SPRINKLER SYSTEMS. CONTRACT WITH: Kartchner Commercial 859 5 Yellowstone, 0201 Rexburg, ID 83440 PHONE NUMBER: 208-529-211(o NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES The records of this organization show that TRENT BICE Automatic Sprinkler System layout 00301 / LEVEL III is certified in the technical area(s) Technician Certification No. 101524 Certifications) Valid Thru 04/01/2018 ol NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES The records of this organization show that BROOK STEWART Automatic Sprinkler System Layout LEVEL 11 is certified in the technical area(s) Technician Certification No. 141221 Certification(s) Valid Thru10/01/2018 Revisions: PER STATE REVIEW 4/05/18