HomeMy WebLinkAboutINSPECTION SUMMARY - 18-00282 - 172 Charles Place - New SFRPermit Inspection Summary Permit Status of (Issue) as of Report Date: 04/15/2019 3:22 pm Permit Details Permit Number: 18-00282 172 Charles Place - New SFR 172 Charles Place Building - Single Family Residence Permit Issued Date: 01/15/2019 Permit Inspection Statistics 22Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 81.82% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/29/2018PassLarry BeesleyResidential Footing Inspection 06/07/2018PassLarry BeesleyFoundation Inspection The foundation forms are set good the re bar is placed correctly in the forms. You are good to pour the concrete. Thanks Inspector Comments: 07/03/2018PassDon AllenRadon-Ground Inspection Radon under ground was ran inside the homeInspector Comments: 09/12/2018PassTed DyeSheeting All sheeting nailed as per codeInspector Comments: 10/03/2018PassLarry BeesleyResidential Framing/Structure Inspection You are good to insulate. I am steel going to check the head room on the stairs to the basement. Thanks, Larry Inspector Comments: 10/08/2018PARTPASSLarry BeesleyResidential Insulation Inspection The fire separation on the up stairs truss on the west end needs to be sheet rocked and inspected before covering any of the ceiling or walls in that area. The head room on the down stairs basement area needs to be fixed before that is sheet rocked. Thanks Inspector Comments: 10/17/2018PassLarry BeesleyCommercial Sheetrock/Drywall Inspection The sheet rock looks good, You are good to tape. ThanksInspector Comments: 01/15/2019PassLarry BeesleyResidential Insulation Inspection The insulation is all good and access openings for the attic are in.Inspector Comments: 01/16/2019PassLarry BeesleyResidential Building Final The house is good for a temporary C.O. There are things that Steve said he would be getting done in the next two or three days. A temporary railing on the front step, the back landing and step installed and ladders in the basement window wells. The garage door is good to enter the house and should be used until the others are completed. The concrete side walks, drive way , grading and the landscaping need to be completed by June 1 2019.Also the road needs to be completed in front of the house. The railing needs to be finished as soon as possible. Thanks Larry Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 18-00282 172 Charles Place - New SFR 172 Charles Place Building - Single Family Residence Permit Status of (Issue) as of Report Date: 04/15/2019 3:22 pm Permit Inspection Summary Electrical Inspection Type 08/22/2018PassBret StoddardCOM & MFR Electrical Service Inspection 09/28/2018FailBret StoddardResidential Electrical Rough-in 10/02/2018PassBret StoddardResidential Electrical Rough-in 12/18/2018FailBret StoddardResidential Electrical Final Inspection 01/02/2019FailBret StoddardResidential Electrical Final Inspection 01/11/2019PassBret StoddardResidential Electrical Final Inspection Mechanical Inspection Type 10/02/2018PassDon AllenHVAC Rough-in 01/15/2019PassDon AllenHVAC Final Inspection Good for certificate of occupancy on the mechanical systemInspector Comments: Plumbing Inspection Type 07/02/2018PassDon AllenPlumbing Underground Inspection 07/03/2018PassDon AllenPlumbing Sewer Good to cove the sewer line.Inspector Comments: 09/14/2018PassDon AllenPlumbing Rough-in 01/15/2019PassDon AllenPlumbing Final Inspection 01/15/2019PassDon AllenPlumbing Water Water is good to cover. The water meter is under snow and cannot get a pictureInspector Comments: Page 2 of 2