HomeMy WebLinkAboutREVIEW REPORT REVISIONS - 17-00373 - 720 Cornelison Ave - Juniper Sands Apartments - Bldg #3 - 56 UnitsReview Report Current Building Review Status: REVISIONS Application Number: 17-00371Permit Details Application Received Date: 07/06/2017 Multi-Family Residential Application Approved Date: Application Approved Status: APPROVED 07/06/2017 Juniper Sands Apartments - Building #1 Status of Plan Reviews Completed 07/11/2017Electrical Review REVISIONS 07/12/2017Plumbing Review COMPLETED 07/12/2017HVAC Review COMPLETED 07/13/2017Fire Department Review - Site Plan COMPLETED 07/21/2017Planning and Zoning Review - Site Plan REVISIONS 07/26/2017Building Review REVISIONS Permit Review Status Plan Reviews Still in Progress Public Works Review - Site Plan Electrical Review Planning and Zoning Review - Site Plan Building Review DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Rated doors and windows meet the requirements of IBC Section 716 REVISIONSDoors at stair enclosures shall be 90 min (revision needed for stair enclosure to be 2 hour - connects 4 stories) *Revisions Response : fireblocking and draftstopping meet the requirements of IBC Section 718 REVISIONS* Identify draft stopping in attic as required by 718.4.2 or per exceptions. * Fire blocking approval will be based on inspection. *Revisions Response : Exit Enclosures meet the requirements of IBC Section 1022 REVISIONS* Barrier required in exit enclosure at stairs descending below the exit discharge level. * Exit enclosure connecting 4 stories shall be 2 hour fire rated. * Required stair signage per 1022.9 is not identified on plans. Recommended for review and approval before installation. * Wall type 7 shows both sides fire rated, even for exterior walls, but 3/4 hour fire protection rated openings are not identified (1022.7) *Revisions Response : Reviewed By: Quinton Owens Review Date: 07/26/2017 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Page 1 of 2 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS All Accessible Routes meet the requirements of IBC Section 1104 REVISIONSAll passage doors in type A units require 3'0" doors. *Revisions Response : Building complies with IECC (IBC, 1301)REVISIONSBuilding needs to meet prescriptive thermal envelope requirements or submit energy compliance report. *Revisions Response : Glass and Glazing meets the requirements of IBC Chapter 24 REVISIONSGlazing less than 36" above landing and within 60" horizontally of the bottom tread of stairs and windows less than 60" above adjacent stairs are hazardous locations and shall be tempered. *Revisions Response : Site Grading meets the requirements of IBC Section 1804.3 Grade shall slope away from building for drainage per 1804.3 COMPLETED Fire barriers meet the requirements of IBC Section 707 Fire riser room and stair enclosure walls are constructed as fire barriers - fire rating extends up to roof or floor deck above regardless of ceiling rating. COMPLETED Penetrations meet the requirements of IBC Section 714 No fire stop penetration details provided. Fire rating of walls and horizontal assemblies shall be maintained at all penetrations. COMPLETED Dwelling Units meet the requirements of IBC Section 1107 3 type A required, 2 one bedroom unit & 1 two bedroom provided. All other ground floor units are type B COMPLETED Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount. meet IBC Sec. 1109 Note: In type A units, Floor & wall finish to be done with removable cabinet allowed under kitchen sink for wheelchair forward approach (not identified on plans). COMPLETED Page 2 of 2 Approval of plans does not constitue approval of variance from code