HomeMy WebLinkAboutINSPECTION SUMMARY - 18-00038 - 311 W 3rd S - Relocated DuplexPermit Inspection Summary Permit Status of (Issue) as of Report Date: 04/11/2019 10:42 am Permit Details Permit Number: 18-00038 311 W 3rd S - Relocated Duplex 311 W 3rd S Building - Single Family Residence Permit Issued Date: 02/26/2018 Permit Inspection Statistics 23Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 65.22% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/26/2018PassLarry BeesleyBuilding Inspection - Site Plan The north and west set backs off the property lines are correct. My concern is that the plot plan measurements are different than the foundation measurements. Plot plan is 27' x 41' the foundation measurements are 25' 11" x 39' x 39' 11" The minimum for set backs on the side yard is 5' or 6" over you get 1 foot of height to the wall height. You are good to dig the foundation. Thanks Inspector Comments: 03/01/2018PassLarry BeesleyResidential Footing Inspection You are good to pour the concrete.Inspector Comments: 03/05/2018PassLarry BeesleyFoundation Inspection Forms and re-bar all looked good. You are OK to pour the concrete. Sam I was looking over your basement foundation plan and noticed that there is a footing that is missing for the stairway wall on the Kitchen side. It can be poured with the floor but it does need to be there. If you have any Questions call me at 208-932-6339 Thanks. Inspector Comments: 04/09/2018FailLarry BeesleyResidential Framing/Structure Inspection This inspection failed mainly because the framing is to be inspected after the plumbing, electrical and the Heating are cone and inspected. I looked over the framing and it does look good at this time. Sam when the plumbing, electrical and the heating is all completed then you will need to call in for a framing inspection again. Thanks Inspector Comments: 05/02/2018FailTed DyeResidential Framing/Structure Inspection Note; There must be a 1hr separation between units.Inspector Comments: 05/07/2018FailLarry BeesleyCommercial Insulation Inspection The insulation used for fire blocking has not been done in the walls next to fur downs for the duct work. The Insulators only did some of the areas. Make the corrections and call for a re inspection. Thanks Inspector Comments: 05/09/2018PassLarry BeesleyResidential Insulation Inspection The insulation for fire blocking is all good now. Thanks Lower the ceiling in the mechanical room and the sheet rock it with the double layer of 5/8" type X sheet rock. Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 18-00038 311 W 3rd S - Relocated Duplex 311 W 3rd S Building - Single Family Residence Permit Status of (Issue) as of Report Date: 04/11/2019 10:42 am Permit Inspection Summary 05/21/2018PassLarry BeesleySidewalk Inspection The gravel is inplace for the sections of sidewalk being replaced.Inspector Comments: 05/21/2018PassLarry BeesleyResidential Sheetrock/Drywall Inspection The screws are all good, and the sheet rock is all good also. The ceiling in the mechanical room steel needs to have the B vent installed before being taped. Also something will need to be done around the sides and back of the furnice duct on the ceiling. Inspector Comments: 06/11/2018PARTPASSLarry BeesleyResidential Sheetrock/Drywall Inspection The sheet rock looks a lot better, but there are steel areas that will need to be fire caulked and covered some how to make a complete seal on the ceiling. Also the B vent for the water heater steel needs to be finished correctly. You will have to have this all completed before your finals. Thanks Inspector Comments: 06/18/2018PassLarry BeesleyResidential Framing/Structure Inspection The straps have been installed correctly as per your engineers letter.Inspector Comments: 07/09/2018FailLarry BeesleyResidential Building Final This shows what is steel needed to be completed. I will talk to Porter to see if we can get a temporary C.O. latter to day if all goes well. Thanks Inspector Comments: 07/10/2018PassLarry BeesleyResidential Building Final This is for only a temporary C.O. The items listed and what ever Quinton requires for the landscaping and parking will need to be completed before a full C.O. can be issued. Thanks Inspector Comments: Electrical Inspection Type 04/18/2018FailBret StoddardResidential Electrical Service Inspection 05/03/2018PassBret StoddardResidential Electrical Service Inspection 05/03/2018PassBret StoddardResidential Electrical Rough-in 07/09/2018PassBret StoddardResidential Electrical Final Inspection Mechanical Inspection Type 05/01/2018FailDon AllenHVAC Rough-in 07/06/2018PassDon AllenHVAC Final Inspection Good for C/O on mechanicalInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 18-00038 311 W 3rd S - Relocated Duplex 311 W 3rd S Building - Single Family Residence Permit Status of (Issue) as of Report Date: 04/11/2019 10:42 am Permit Inspection Summary Plumbing Inspection Type 03/13/2018PassDon AllenPlumbing Underground Inspection Good to cover nthe plumbing underground.Inspector Comments: 03/15/2018PassDon AllenPlumbing Underground Inspection Sewer line was to shallow coming out of the foundation so a sewer injector pump needed to be installed. The sewer injector pump that was added to the ground work wad installed to the code. Inspector Comments: 05/02/2018PassDon AllenPlumbing Rough-in 07/06/2018FailDon AllenPlumbing Final Inspection Inspections Required Plumbing Final Inspection Planning and Zoning Final Inspection Page 3 of 3