HomeMy WebLinkAboutINSPECTION SUMMARY - 18-00038 - 311 W 3rd S - Relocated DuplexPermit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 04/11/2019 10:42 am
Permit Details Permit Number: 18-00038
311 W 3rd S - Relocated Duplex
311 W 3rd S
Building - Single Family Residence
Permit Issued Date: 02/26/2018
Permit Inspection Statistics
23Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 65.22%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
02/26/2018PassLarry BeesleyBuilding Inspection - Site Plan
The north and west set backs off the property lines are correct. My concern is
that the plot plan measurements are different than the foundation
measurements. Plot plan is 27' x 41' the foundation measurements are 25' 11"
x 39' x 39' 11" The minimum for set backs on the side yard is 5' or 6" over
you get 1 foot of height to the wall height. You are good to dig the foundation.
Thanks
Inspector Comments:
03/01/2018PassLarry BeesleyResidential Footing Inspection
You are good to pour the concrete.Inspector Comments:
03/05/2018PassLarry BeesleyFoundation Inspection
Forms and re-bar all looked good. You are OK to pour the concrete. Sam I was
looking over your basement foundation plan and noticed that there is a footing
that is missing for the stairway wall on the Kitchen side. It can be poured with
the floor but it does need to be there. If you have any Questions call me at
208-932-6339 Thanks.
Inspector Comments:
04/09/2018FailLarry BeesleyResidential Framing/Structure Inspection
This inspection failed mainly because the framing is to be inspected after the
plumbing, electrical and the Heating are cone and inspected. I looked over the
framing and it does look good at this time. Sam when the plumbing, electrical
and the heating is all completed then you will need to call in for a framing
inspection again. Thanks
Inspector Comments:
05/02/2018FailTed DyeResidential Framing/Structure Inspection
Note; There must be a 1hr separation between units.Inspector Comments:
05/07/2018FailLarry BeesleyCommercial Insulation Inspection
The insulation used for fire blocking has not been done in the walls next to fur
downs for the duct work. The Insulators only did some of the areas. Make the
corrections and call for a re inspection. Thanks
Inspector Comments:
05/09/2018PassLarry BeesleyResidential Insulation Inspection
The insulation for fire blocking is all good now. Thanks Lower the ceiling in the
mechanical room and the sheet rock it with the double layer of 5/8" type X sheet
rock.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 18-00038
311 W 3rd S - Relocated Duplex
311 W 3rd S
Building - Single Family Residence
Permit Status of (Issue) as of Report Date: 04/11/2019 10:42 am
Permit
Inspection
Summary
05/21/2018PassLarry BeesleySidewalk Inspection
The gravel is inplace for the sections of sidewalk being replaced.Inspector Comments:
05/21/2018PassLarry BeesleyResidential Sheetrock/Drywall Inspection
The screws are all good, and the sheet rock is all good also. The ceiling in the
mechanical room steel needs to have the B vent installed before being taped.
Also something will need to be done around the sides and back of the furnice
duct on the ceiling.
Inspector Comments:
06/11/2018PARTPASSLarry BeesleyResidential Sheetrock/Drywall Inspection
The sheet rock looks a lot better, but there are steel areas that will need to be
fire caulked and covered some how to make a complete seal on the ceiling. Also
the B vent for the water heater steel needs to be finished correctly. You will have
to have this all completed before your finals. Thanks
Inspector Comments:
06/18/2018PassLarry BeesleyResidential Framing/Structure Inspection
The straps have been installed correctly as per your engineers letter.Inspector Comments:
07/09/2018FailLarry BeesleyResidential Building Final
This shows what is steel needed to be completed. I will talk to Porter to see if we
can get a temporary C.O. latter to day if all goes well. Thanks
Inspector Comments:
07/10/2018PassLarry BeesleyResidential Building Final
This is for only a temporary C.O. The items listed and what ever Quinton requires
for the landscaping and parking will need to be completed before a full C.O. can
be issued. Thanks
Inspector Comments:
Electrical Inspection Type
04/18/2018FailBret StoddardResidential Electrical Service Inspection
05/03/2018PassBret StoddardResidential Electrical Service Inspection
05/03/2018PassBret StoddardResidential Electrical Rough-in
07/09/2018PassBret StoddardResidential Electrical Final Inspection
Mechanical Inspection Type
05/01/2018FailDon AllenHVAC Rough-in
07/06/2018PassDon AllenHVAC Final Inspection
Good for C/O on mechanicalInspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 18-00038
311 W 3rd S - Relocated Duplex
311 W 3rd S
Building - Single Family Residence
Permit Status of (Issue) as of Report Date: 04/11/2019 10:42 am
Permit
Inspection
Summary
Plumbing Inspection Type
03/13/2018PassDon AllenPlumbing Underground Inspection
Good to cover nthe plumbing underground.Inspector Comments:
03/15/2018PassDon AllenPlumbing Underground Inspection
Sewer line was to shallow coming out of the foundation so a sewer injector pump
needed to be installed. The sewer injector pump that was added to the ground
work wad installed to the code.
Inspector Comments:
05/02/2018PassDon AllenPlumbing Rough-in
07/06/2018FailDon AllenPlumbing Final Inspection
Inspections Required
Plumbing Final Inspection
Planning and Zoning Final Inspection