HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00460 - 814 S 2275 W - Kartchner SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 04/10/2019 10:03 am
Permit Details Permit Number: 17-00460
814 S 2275 W - Kartchner SFR
814 S 2275 W
Building - Single Family Residence
Permit Issued Date: 08/17/2017
Permit Inspection Statistics
24Total Inspections Completed:
19Total Inspections Passed:
Inspection Pass Rate: 79.17%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
08/23/2017PassLarry BeesleyFoundation Inspection
Looks good .OK to pour concrete.8-23-17Inspector Comments:
08/23/2017PassLarry BeesleyResidential Footing Inspection
The footings look good. OK to pour. Thanks 8-23-17Inspector Comments:
01/16/2018PARTPASSLarry BeesleySheeting
The wall sheeting is good and you can put the house wrap on . The 7/16" roof
sheeting was installed without H clips that provide the mid span edge support,so
according to the code there needs to be solid blocking that the OSB is nailed or
stapled to. This needs to be done before the roofing is installed. Call in for a re
inspection on the roof sheeting after blocks are installed. Thanks
Inspector Comments:
01/31/2018PassLarry BeesleySheeting
1 stud needs to be nailed,I will inspect when I do the framing re inspection.Inspector Comments:
01/31/2018FailLarry BeesleyResidential Framing/Structure Inspection
02/01/2018PassLarry BeesleyResidential Framing/Structure Inspection
Thanks for making the corrections that were needed. 2-1-18Inspector Comments:
02/05/2018PassLarry BeesleyResidential Insulation Inspection
You are OK to sheet rock.Inspector Comments:
02/09/2018PassLarry BeesleyResidential Sheetrock/Drywall Inspection
The drywall is all hung and screwed as per the code. You are good to tape.
THANKS
Inspector Comments:
04/04/2018PassLarry BeesleyResidential Building Final
The inspections are all good. there are a few things that need to be completed
for the final C.O. They are out side concrete, grading around the house, concrete
and the water meter.
Inspector Comments:
06/11/2018PassLarry BeesleySidewalk Inspection
Gravel is good , OK to pour the concrete.Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 17-00460
814 S 2275 W - Kartchner SFR
814 S 2275 W
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 04/10/2019 10:03 am
Permit
Inspection
Summary
Electrical Inspection Type
09/07/2017PassBret StoddardResidential Electrical Service Inspection
01/31/2018PassBret StoddardResidential Electrical Rough-in
03/26/2018PassBret StoddardResidential Electrical Final Inspection
04/04/2018PassBret StoddardResidential Electrical Final Inspection
Mechanical Inspection Type
01/30/2018PassDon AllenHVAC Rough-in
03/23/2018FailDon AllenHVAC Final Inspection
04/04/2018PassDon AllenHVAC Final Inspection
Plumbing Inspection Type
08/29/2017PassDon AllenPlumbing Water
GOOD TO COVER THE WATER LINE. WILL LOOK AT THE WATER METER FOR
FINAL GRADE AT THE FINAL OFTHE HOME
Inspector Comments:
08/29/2017PassDon AllenPlumbing Sewer
GOOD TO COVER THE SEWER LINEInspector Comments:
09/12/2017PassDon AllenPlumbing Underground Inspection
Pass.
- Shane Hill
Inspector Comments:
01/24/2018PassDon AllenPlumbing Rough-in
03/23/2018PARTPASSDon AllenPlumbing Final Inspection
04/04/2018PARTPASSDon AllenPlumbing Final Inspection
12/14/2018PassDon AllenPlumbing Final Inspection
Inspections Required
Radon-Ground Inspection