HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00445 - 1005 N 2nd E - Oswald Service and RepairPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 04/10/2019 8:05 am
Permit Details Permit Number: 17-00445
1005 N 2nd E - Oswald Service and Repair
1005 N 2nd E
Building - Commercial
Permit Issued Date: 12/13/2017
Permit Inspection Statistics
30Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 56.67%
Permit Inspection History *Refer to Individual Inspection Report for more Details
08/14/2018PARTPASSJoel GrayPublic Works Final Inspection
Trash Enclosure has not been completed.Inspector Comments:
08/22/2018FailQuinton OwensPlanning and Zoning Final Inspection
Only trees planted as a buffer. Development Code requires a 2" min. caliper tree
and 5 bushes/shrubs every 30 ft. (Section 4.7.a.1).
Inspector Comments:
09/05/2018PassQuinton OwensPlanning and Zoning Final Inspection
Buffer is completed with trees and bushes. Dumpster enclosure walls are done.Inspector Comments:
10/09/2018PassJoel GrayPublic Works Final Inspection
Trash Enclosure to be completed per letter from owner.
Completed 10/22/2018 JG
Inspector Comments:
Building Inspection Type
12/13/2017PARTPASSQuinton OwensCommercial Footing Inspection
* Exterior footings and footing between shop and office section inspected.
* Protect concrete from cold weather as per ACI 318
* Don't forget interior footing inspection.
Inspector Comments:
12/14/2017PassQuinton OwensFoundation Inspection
Protect concrete from freezing per ACI 318Inspector Comments:
01/12/2018PARTPASSQuinton OwensCommercial Insulation Inspection
Footing inspection requested? Recessed footing trench is covered with blankets,
snow and water. Clean out footing trench and grade shall be free of frost.
Inspector Comments:
01/12/2018PassQuinton OwensCommercial Footing Inspection
01/31/2018PassTed DyeSheeting
sheeting stapled as per codeInspector Comments:
03/16/2018FailQuinton OwensCommercial Framing/Structure Inspection
*** Approved to insulate WALLS only. Corrections may be inspected with
insulation ***
Inspector Comments:
03/21/2018FailQuinton OwensCommercial Framing/Structure Inspection
APPROVED FOR INSULATION PER COMMENTS. ABOVE ITEMS WILL BE
RE-INSPECTED WITH INSULATION.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 17-00445
1005 N 2nd E - Oswald Service and Repair
1005 N 2nd E
Building - Commercial
Permit Status of (Open) as of Report Date: 04/10/2019 8:05 am
Permit
Inspection
Summary
03/27/2018PassQuinton OwensCommercial Insulation Inspection
Approved for cover - Seal perimeter of front doorInspector Comments:
03/29/2018PassQuinton OwensCommercial Framing/Structure Inspection
Approved for coverInspector Comments:
05/30/2018PARTPASSQuinton OwensSidewalk Inspection
remaining sidewalk at north end approved to pour.
Rest of sidewalk and approach on south end still to be completed.
Inspector Comments:
06/05/2018PARTPASSQuinton OwensCommercial Building Final
06/05/2018N/AQuinton OwensCommercial Sheetrock/Drywall Inspection
Sheetrock inspection was never requested for nailing. No approval is given on
drywall, however there are no fire rated walls required on this building.
WARNING: ALWAYS CALL FOR DRYWALL INSPECTION BEFORE TAPING!
Inspector Comments:
07/26/2018PassTed DyeCommercial Building Final
Electrical Inspection Type
02/15/2018PassBret StoddardCOM & MFR Electrical Service Inspection
03/15/2018PassBret StoddardCommercial Electrical Rough-in
06/01/2018FailBret StoddardCommerical Electrical Final Inspection
12/12/2018PassBret StoddardCommercial Electrical Final Inspection
Fire Inspection Type
06/05/2018N/AQuinton OwensFire Sprinkler Final Inspection
3 Fire extinguishers in building. One in office area and 2 in garage.Inspector Comments:
06/07/2018PassDale PickeringFire Department Final Inspection
Mechanical Inspection Type
03/16/2018PassDon AllenHVAC Rough-in
No gas line is installed. Good to cover the mechanical rough-inInspector Comments:
06/01/2018PassDon AllenHVAC Final Inspection
Good for the C/OInspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 17-00445
1005 N 2nd E - Oswald Service and Repair
1005 N 2nd E
Building - Commercial
Permit Status of (Open) as of Report Date: 04/10/2019 8:05 am
Permit
Inspection
Summary
Plumbing Inspection Type
02/13/2018PARTPASSDon AllenPlumbing Water
Good to cover the water line. Will look at the water meter at the final of project
for final grade and meter height of the water meter.
Inspector Comments:
02/23/2018PassDon AllenPlumbing Underground Inspection
Good to cover the plumbing undergroundInspector Comments:
03/16/2018PassDon AllenPlumbing Rough-in
Good to cover the plumbing rough-inInspector Comments:
06/01/2018PassDon AllenPlumbing Final Inspection
12/12/2018N/ADon AllenPlumbing Sewer
Page 3 of 3