Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00285 - 398 Pioneer Rd - Rocky Ridge Apartments - Bldg 1 - 4 plexPermit Inspection Summary Permit Status of (Open) as of Report Date: 04/03/2019 11:17 am Permit Details Permit Number: 17-00285 398 Pioneer Rd - Rocky Ridge Apartments - Bldg 1 - 4 plex 398 Pioneer Rd Multi-Family Residential Permit Issued Date: 02/23/2018 Permit Inspection Statistics 39Total Inspections Completed: 27Total Inspections Passed: Inspection Pass Rate: 69.23% Permit Inspection History *Refer to Individual Inspection Report for more Details 10/03/2018PARTPASSJoel GrayPublic Works Final Inspection Fire hydrants near buildings 15 and 11 are too low. Hydrant bottom must be between 3 and 9" above finished grade. Some storz adapters not installed yet. Inspector Comments: 10/09/2018PassJoel GrayPublic Works Final Inspection 12/05/2018PassQuinton OwensPlanning and Zoning Final Inspection Landscaping is completed for building 1. P&Z approved for occupancy Inspector Comments: Building Inspection Type 07/18/2017PassTed DyeCommercial Footing Inspection 07/26/2017PassTed DyeFoundation Inspection 08/23/2017PassTed DyeCommercial Insulation Inspection 09/25/2017FailTed DyeSheeting Sheeting that missed being nailed to the studs has been marked with green paint. Inspector Comments: 10/03/2017PassQuinton OwensSheeting Sheathing corrections have been made at marked locations.Inspector Comments: 10/29/2017FailTed DyeCommercial Framing/Structure Inspection 10/30/2017FailTed DyeCommercial Framing/Structure Inspection 10/31/2017PassTed DyeCommercial Insulation Inspection 11/03/2017FailTed DyeCommercial Sheetrock/Drywall Inspection 11/06/2017PassTed DyeCommercial Sheetrock/Drywall Inspection Both main level units require solid metal cover over clean outs in rated walls to protect penetrations. Inspector Comments: Site address shall be provided and easily visible from street. Building and unit numbers are posted. Inspector Comments: Vent termination covers between buildings shall be metal with damper and cover opening downward. Inspector Comments: 02/08/2018FailQuinton OwensCommercial Building Final 1102 missing living rm sprinkler escutcheon - also in 1202 hall closet.Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 17-00285 398 Pioneer Rd - Rocky Ridge Apartments - Bldg 1 - 4 plex 398 Pioneer Rd Multi-Family Residential Permit Status of (Open) as of Report Date: 04/03/2019 11:17 am Permit Inspection Summary 02/16/2018PassQuinton OwensCommercial Framing/Structure Inspection 02/16/2018FailQuinton OwensCommercial Building Final * North main level unit fire rating at clean out under bathroom sink in rated party wall is not completed. * Metal clean out cover installed on south unit party wall - approved Inspector Comments: * Metal cleanout cover under bathroom sink in north unit required to protect penetration. (completed per Ted) * Site address is not posted (Minumum 4" tall numbers or larger if needed - easily visible from street) Inspector Comments: 02/26/2018FailQuinton OwensCommercial Building Final Temporary occupancy approved. Post temporary address sign immediately if waiting for permanent signage to completed. Inspector Comments: 10/04/2018PassQuinton OwensCommercial Building Final Electrical Inspection Type 10/25/2017PassBret StoddardCommercial Electrical Rough-in 11/27/2017PassBret StoddardCommercial Electrical Rough-in 01/16/2018PassBret StoddardResidential Electrical Service Inspection 02/01/2018PassBret StoddardResidential Electrical Final Inspection Fire Inspection Type 10/24/2017PassDale PickeringFire Sprinkler Rough-in 01/29/2018FailBret StoddardFire Alarm Final Inspection 01/30/2018PassDale PickeringFire Sprinkler Final Inspection 01/30/2018PassBret StoddardFire Alarm Final Inspection 10/01/2018PassDale PickeringFire Department Inspection 10/09/2018PassDale PickeringFire Department Final Inspection Mechanical Inspection Type 10/27/2017FailDon AllenHVAC Rough-in 10/30/2017PassDon AllenHVAC Rough-in Good to cover the mechanical rough inInspector Comments: 02/26/2018PassDon AllenHVAC Final Inspection Page 2 of 3 (Continued) Permit Details Permit Number: 17-00285 398 Pioneer Rd - Rocky Ridge Apartments - Bldg 1 - 4 plex 398 Pioneer Rd Multi-Family Residential Permit Status of (Open) as of Report Date: 04/03/2019 11:17 am Permit Inspection Summary Planning & Zoning 03/07/2018PARTPASSQuinton OwensPlanning and Zoning Final Inspection P&Z Final approved for temporary occupancy * Landscaping to be done as soon as weather permits * PUD requirements will be verified. Inspector Comments: Plumbing Inspection Type 08/24/2017PassDon AllenPlumbing Underground Inspection 09/19/2017PassDon AllenPlumbing Water 6 inch main water line held test good to coverInspector Comments: 10/20/2017PassDon AllenPlumbing Sewer 10/27/2017FailDon AllenPlumbing Rough-in 10/30/2017PassDon AllenPlumbing Rough-in Good to cover the plumbing rough in on building 1Inspector Comments: 12/15/2017PassDon AllenPlumbing Water Good to cover the water lineInspector Comments: 02/26/2018PassDon AllenPlumbing Final Inspection Page 3 of 3