HomeMy WebLinkAboutUPDATED PLANS - 19-00027 - Cell Tower - Adding Additional AmplifiersTITLE SHEET IDL04328 REXBURG STEINER ELEVATOR FA#: 10133809 120' MONOPOLE PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: T-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology SITE INFORMATION SITE ADDRESS:164 WEST 1ST NORTH REXBURG, IDAHO 83440 COUNTY:MADISON COORDINATES: 43.8285417° / -111.7878083° (FOR NAVIGATION ONLY) PROPERTY LANDLORD OR OWNER:STEINER ELEVATORS INC JURISDICTION:MADISON COUNTY OCCUPANCY GROUP UNMANNED CONSTRUCTION TYPE II-B POWER COMPANY:ROCKY MOUNTAIN POWER TELCO COMPANY:CENTURYLINK A.D.A. COMPLIANCE:FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF ALL GOVERNING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. WORK PERFORMED IN VIOLATION OF THESE CODES IS NOT ALLOWED. FCC COMPLIANCE RADIATION FROM THIS FACILITY WILL NOT INTERFERE WITH OPERATION OF OTHER COMMUNICATION DEVICES. SHEET INDEX SHEET DESCRIPTION T-1 TITLE SHEET GN-1 GENERAL NOTES A-0 OVERALL SITE PLAN A-1 SITE PLAN A-2 EQUIPMENT PLAN A-3 ANTENNA ELEVATIONS A-4 ANTENNA PLANS R-1 EQUIPMENT DETAILS R-2 MOUNT DETAIL G-1 GROUNDING DETAILS E-2 ELECTRICAL DETAILS G-1 GROUNDING PLAN G-2 GROUNDING DETAILS DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS, CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. at t & VICINITY MAP SITE TOWER ELEVATIONSCOPE OF WORK REMOVE: (3) PANEL ANTENNAS (3) RRH UNITS PROPOSED: (3) KATHREIN 80010992 (3) NOKIA AIRSCALE DUAL RRH 4T4R B12/14 320W AHLBA LTE RACK & DC POWER PLANT UPGRADES LTE 5C - 3771A0JHS3 CONTACT INFORMATION APPLICANT:AT&T 4393 RIVERBOAT ROAD, SUITE 400 TAYLORSVILLE, UTAH 84123 PHONE: 801.458.8888 CONTACT: BYRON BOSSHARDT PROJECT MANAGER:GENERAL DYNAMICS WIRELESS SERVICES, LLC. 1152 W. 2400 S., SUITE C SALT LAKE CITY, UT 84119 PHONE: 801.201.0566 CONTACT: ROCKY MATTISON ARCHITECTURE & ENGINEERING: GEOSTRUCTURAL, LLC. PO BOX 2621 BOISE, ID 83701 PHONE: 530.539.4787 CONTACT: DON GEORGE N GOOGLE MAPS 2019 DRIVING DIRECTIONS From Idaho Falls Regional Airport: Turn right to stay on N Skyline Dr (1.1 mi) Turn left onto Grandview Dr / US-20 (26.0 mi) At exit 333, take ramp right for ID-33 toward Hospital / Rexburg / Salmon Turn right onto ID-33 / W Main St (1.0 mi) Turn left onto N 2nd W (0.1 mi) Turn right onto W 1st N (456 ft) Site on left side of road APPROVALS RF MANAGER ______________________________________________ CONSTRUCTION MANAGER ______________________________________________ SITE ACQ. MANAGER ______________________________________________ PROPERTY OWNER ______________________________________________ OPERATIONS MANAGER ______________________________________________ R DIG LINE THE PLANS SHOW SOME KNOWN SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES, AND/OR EXISTING UTILITIES BELIEVED TO BE IN THE WORKING AREA. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL UTILITIES, PIPELINES AND OTHER STRUCTURES SHOWN OR NOT SHOWN ON THESE PLANS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND ENGINEER AT THE CONTRACTOR'S EXPENSE. GENERAL CONSTRUCTION NOTES 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: GENERAL CONTRACTOR: TBD SUB-CONTRACTOR: TBD 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING, MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO BE FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS. SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH WORK. 8. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE SPACE FOR APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER SUB-CONTRACTORS. 12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED PROFESSIONALS. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. SUB-CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. SUB-CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWING PRIOR TO THE BEGINNING CONSTRUCTION. 15. SUB-CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK. 16. THE SUB-CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUB-CONTRACTORS EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE SUB-CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND SUB-CONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS WITH ALL REVISION, ADDENDA, AND CHANGES ORDERS ON THE PREMISES AT ALL TIMES. 21. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 22. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH GRADE AND COMPACTED TO 95% OF STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL, PRE-APPROVED BY THE LOCAL JURISDICTION. 23. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. GENERAL ELECTRICAL NOTES 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE CURRENTLY IN EFFECT FOR THE AUTHORITY HAVING JURISDICTION. 2. ALL GROUNDING DEVICES SHALL BE U.L. LISTED FOR THEIR INTENDED USE. 3. GROUND WIRES SHALL BE TINNED #2 AWG BARE SOLID COPPER UNLESS OTHERWISE NOTED. 4. CONNECTIONS OF ALL GROUND WIRES TO THE GROUND RING SHALL BE EXOTHERMIC (CAD-WELDED), UNLESS OTHERWISE NOTED AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND AT&T WIRELESS BROADBAND STANDARDS. 5. GROUNDING CONDUCTORS SHALL BE ROUTED ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE WHEN REQUIRED. GROUND LEADS SHALL BE BENT TO A MINIMUM OF 8' RADIUS. 6. WHERE GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO THE GROUND RING, INSTALL WIRE IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5' BELOW GRADE AND SEAL THE TOP WITH SILICONE SEALANT. 7. ALL GROUND BARS SHALL BE TINNED COPPER, SECTOR BARS 2", COLLECTOR AND MGB BARS 4", OF SUFFICIENT LENGTH TO ACCOMMODATE ALL REQUIRED CONNECTIONS WITHOUT DOUBLING LUGS, AND EACH INSTALLED WITH ISOLATORS. WHEN CONNECTING GROUND BARS (WITHIN 10 FEET OF GRADE) DIRECTLY TO THE GROUND RING, 2 EA. #2 SOLID DOWNLEADS SHALL BE CAD-WELDED TO THE GROUNDING, 1 AT EACH OPPOSITE BOTTOM CORNER, AND EACH SHALL RUN IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM GROUND BAR DOWN TO THE GROUND RING, WHEN CONNECTING SECTOR GROUND BARS, DAISY-CHAIN THE GROUND BARS AND RUN 1 EA. #2 AWG STRANDED COPPER WIRE WITH THWN INSULATION FROM THE MIDDLE GROUND BAR TO THE GROUND RING AND CAD-WELD TO THE RING. 8. WHEN ATTACHING STRANDED GROUND LEADS TO THE GROUND BARS, 2 HOLE COMPRESSION LUGS SHALL BE USED, PROTECT WITH WEATHERPROOF HEAT SHRINK, AND WITH A THIN COAT OF "KOPR-SHIELD' OR EQUIVALENT COMPOUND; PROPERLY APPLIED AND ATTACHED ONLY WITH STAINLESS STEEL HARDWARE. 9. WHEN GROUNDING EQUIPMENT ENCLOSURES, PANELS, FRAMES, AND OTHER METAL APPARATUS, A #6 AWG STRANDED COPPER WIRE WITH THWN INSULATlON SHALL BE ATTACHED UTILIZING A 2 HOLE COMPRESSION TYPE LUG, PROTECTED WITH WEATHERPROOFING. HEAT AND CLEAN A CORROSION FREE METALLIC SURFACE UTILIZING STAINLESS STEEL SELF-TAPPING SCREWS AS NOTED IN NOTE 10 BELOW. 10. PREPARE ALL BONDING SURFACES FOR GROUND CONNECTIONS BY REMOVING ANY AND ALL PAINT AND CORROSION TO SHINY METAL. CAD-WELDED CONNECTIONS TO NON-COPPER SURFACES, APPLY ONE COAT OF ANY ANTI-OXIDIZING PAINT, "COLD GALV" OR EQUIVALENT. 11. GROUND RODS SHALL BE COPPER-CLAD STEEL 5/8"x10', SPACED NO LESS THAN 10' ON CENTER. 12. ALL GROUND SYSTEM CONDUCTORS AND CONDUITS SHALL BE SECURED UTILIZING ONLY NON-METALLIC, NON-CONDUCTIVE, UV RATED CLAMPS, BRACKET, AND OR SUPPORTS. 13. WHEN REQUIRED, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF AN INDEPENDENT TESTING FIRM TO VERIFY, UTILIZING A MEGGER TEST, THAT THE RESISTANCE TO EARTH OF THE NEW GROUND SYSTEM IS EQUAL TO OR LESS THAN 5 (OHMS). A COPY OF THE COMPLETE TESTING REPORT SHALL BE PROVIDED TO THE AT&T REPRESENTATIVE. 14. ALL MATERIALS AND HARDWARE SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND DEFINED IN NFPA-70. 15. ALL RRH GROUND WIRES SHALL BE #2 GREEN STRANDED. 16. ALL GROUND LUGS SHALL BE 2-HOLE LONG BARRELL. 17. OUTDOOR GROUNDS SHALL BE BLACK HEAT SHRINK W/O INSPECTION HOLES. 18. INDOOR GROUNDS SHALL BE CLEAR HEAT SHRINK W/ INSPECTION HOLES. ANTENNA MOUNT PIPES 1. PROPOSED OR REPLACEMENT ANTENNA PIPE MOUNTS SHALL BE 2-3/8" (O.D.)X10', SCH. 80 PIPE., U.N.O. V2 GENERAL PROJECT NOTES 1. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF/HERSELF WITH THE SCOPE OF WORK AND ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. 2. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS OF THE JOB SITE AND CONFIRM THAT WORK AS INDICATED ON THESE CONSTRUCTION DOCUMENTS CAN BE ACCOMPLISHED AS SHOWN PRIOR TO COMMENCEMENT OF ANY WORK. 3. ALL FIELD MODIFICATIONS BEFORE, DURING, OR AFTER CONSTRUCTION SHALL BE APPROVED IN WRITING BY AN AT&T REPRESENTATIVE. 4. INSTALL ALL EQUIPMENT AND MATERIALS PER THE MANUFACTURER'S RECOMMENDATIONS, U.N.O. 5. NOTIFY AT&T, IN WRITING, OF ANY MAJOR DISCREPANCIES REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND DESIGN INTENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATIONS FROM AN AT&T REPRESENTATIVE AND ADJUSTING THE BID ACCORDINGLY. 6. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK UNDER THE CONTRACT. 7. CONTRACTOR SHALL PROTECT ALL EXISTING IMPROVEMENTS AND FINISHES THAT ARE TO REMAIN. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY OCCUR DURING THE CONSTRUCTION TO THE SATISFACTION OF AN AT&T REPRESENTATIVE. 8. THE CONTRACTOR IS RESPONSIBLE FOR RED-LINING THE CONSTRUCTION PLANS TO ILLUSTRATE THE AS BUILT CONDITION OF THE SITE. FOLLOWING THE FINAL INSPECTION BY AT&T,THE CONTRACTOR SHALL PROVIDE AT&T WITH ONE COPY OF ALL RED-LINED DRAWINGS. 9. VERIFY ALL FINAL EQUIPMENT WITH AN AT&T REPRESENTATIVE. ALL EQUIPMENT LAYOUT, SPECS, PERFORMANCE INSTALLATION AND THEIR FINAL LOCATION ARE TO BE APPROVED BY AT&T. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS/HER WORK WITH THE WORK AND CLEARANCES REQUIRED BY OTHERS RELATED TO SAID INSTALLATIONS. GENERAL NOTES PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: GN-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology SITE PLAN PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: A-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology SITE PLAN N 164 WEST 1ST NORTH REXBURG, IDAHO 83440 R KEY [E]EXISTING [P]PROPOSED UTILITY NOTE THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM RECORD INFORMATION. THE INFORMATION PROVIDED IS IMPLIED NOT INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. NOTE EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED N.T.S.1SCALE: 3/16" = 1'-0" (11x17)2 NOT USED EXISTING CONDITIONS THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION, GEOSTRUCTURAL DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. MONOPOLE TOWER ICE-BRIDGE 12'x11'-6" AT&T SHELTER HVAC HVAC UTILITY H-FRAME DIESEL GENERATOR 12' WIDE DOUBLE SWING GATE CONCRETE STOOP EQUIPMENT PLAN PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: A-2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology N.T.S.1PROPOSED EQUIPMENT PLAN SCALE: 3/8" = 1'-0" (11x17)2 NOT USED NOTE EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED PROPOSED: (3) 50 AMP EMERSON BREAKERS (2) EMERSON -48V RECTIFIERS PROPOSED: (1) ABIA CARD (6) SFPs INSTALLED IN LTE RACK ICE BRIDGE HVACHVAC ACCESS CONCRETE PAD ANTENNA ELEVATIONS PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: A-3 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 1ANTENNA ELEVATIONS SCALE N.T.S. STRUCTURE NOTES CONTRACTOR TO COMPLY WITH ALL FCC AND FAA REGULATIONS ON THIS PROJECT. REFER TO TOWER MAPPING FOR ALL EXISTING COMPONENTS AND APPURTENANCES. PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY THAT A TOWER STRUCTURAL ANALYSIS AND A MOUNT ANALYSIS HAS BEEN PERFORMED AND SHOWS A "PASS" OR AN "ACCEPTABLE" RATING. UNDER NO CIRCUMSTANCE WHATSOEVER SHALL THE PROPOSED EQUIPMENT BE INSTALLED WITHOUT SAID STRUCTURAL ANALYSIS. IF SAID STRUCTURAL ANALYSIS REQUIRES THAT THE STRUCTURE AND/OR MOUNT BE MODIFIED, SUCH MODIFICATIONS SHALL BE COMPLETED PRIOR TO INSTALLATION OF THE PROPOSED EQUIPMENT. EXISTING CONDITIONS THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO INSTALLATION. BOTTOM OF BASE PLATE 0' AT&T SHELTER AT&T RAD CENTER EXISTING TO BE REMOVED (3) EXISTING ANTENNAS TOP OF TOWER 120'± CHAIN-LINK FENCEICE-BRIDGE GENERATOR GRADE BOTTOM OF BASE PLATE 0' AT&T SHELTER AT&T RAD CENTER FINAL (6) EXISTING ANTENNAS (3) PROPOSED ANTENNAS FINAL (3) PROPOSED RRH UNITS (9) EXISTING RRH UNITS TOP OF TOWER 120'± CHAIN-LINK FENCEICE-BRIDGE GENERATOR GRADE EXISTING ANTENNA ELEVATION FINAL ANTENNA ELEVATION EXISTING (3) EXISTING DC/FIBER BOXES EXISTING TO REMAIN (6) EXISTING ANTENNAS EXISTING TO BE REMOVED (3) EXISTING RRHs EXISTING TO REMAIN (9) EXISTING RRHs ANTENNA PLANS PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: A-4 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology ANTENNA PLANS INSTALLATION NOTES 1.ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS, MOUNTING HARDWARE AND RF DESIGN. ANTENNA PIPE MOUNT MODIFICATION MAY BE REQUIRED PER MOUNT ANALYSIS (BY OTHERS). 2.CONTRACTOR TO VERIFY FINAL ANTENNA CONFIGURATION FROM LATEST APPROVED RFDS. 3.CONTRACTOR SHALL OBTAIN A MINIMUM 4' SEPARATION BETWEEN ALL ANTENNAS UNLESS APPROVED BY RF. 4.STRUCTURAL ANALYSIS MUST BE PERFORMED PRIOR TO THE INSTALLATION OF ANY NEW EQUIPMENT. N N.T.S.1N.T.S.2 NOT USED EXISTING CONDITIONS THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO INSTALLATION. EXISTING (3) DC/FIBER BOXES EXISTING (3) B25 RRH4x30-4R (3) RRH4x25-WCS-4R (3) NOKIA AIRSCALE DUAL RRH 4T4R B25/66 320W AHFIB STACKED ON PIPE EXISTING (3) SBNHH-1D65C PANEL ANTENNAS EXISTING (3) POWERWAVE LGP 18-601 TMA EXISTING (3) RV4PX310R-V2 PANEL ANTENNAS EXISTING (3) SBNHH-1D65C PANEL ANTENNAS . 240 ° TN 12 0 ° T N . PROPOSED (3) NOKIA AIRSCALE DUAL RRH 4T4R B12/14 320W AHLBA INSTALLED ON MOUNT PIPES ATTACHED TO PLATFORM STANDOFF MEMBERS UTILIZING SITEPRO1 BBPM (OR APPROVED EQUAL) EXISTING TO BE REMOVED (3) SBNHH-1D65C PANEL ANTENNAS EXISTING (3) DC/FIBER BOXES EXISTING (3) B25 RRH4x30-4R (3) RRH4x25-WCS-4R (3) NOKIA AIRSCALE DUAL RRH 4T4R B25/66 320W AHFIB STACKED ON PIPE EXISTING (3) RV4PX310R-V2 PANEL ANTENNAS . 0 ° T N FINAL ANTENNA SECTION EXISTING ANTENNA SECTION PROPOSED (3) KATHREIN 80010992 PANEL ANTENNAS AZ = 0° 120° 240° EXISTING TO BE REMOVED (3) RRH2x40W-07AT RRH ANTENNA AND RRH INSTALLATION NOTE ANTENNAS AND EQUIPMENT SHALL BE INSTALLED CENTERED VERTICALLY ON THE MOUNT FRONT FACE BOTTOM RAIL (LIMIT VERTICAL INSTALLATION ECCENTRICITY) WITH A MAXIMUM VERTICAL ECCENTRICITY OF 12” FOR PANELS AND 18” FOR RRHS. V1 NOTES: 1.CONCRETE ANCHOR:HILTI HIT HY 150 ADHESIVE ANCHOR SIZE:Ø = 3/8" EMBEDMENT:1 3/4" SPACING:S = 24" (MAX) * IF THE WALL THICKNESS IS LESS THAN 2", THE 1/2"Ø A325 BOLT SHALL BE USED TO GO THROUGH THE WALL WITH A 3/8" BACK PLATE INSIDE OF THE WALL. 2.FULLY-GROUTED CMU WALL ANCHOR:HILTI HIT HY 150 ADHESIVE ANCHOR SIZE:Ø = 3/8" EMBEDMENT:1 3/4" SPACING:ONE (1) ANCHOR PER CELL (MAX) AND 8" (MIN) 3.SOLID BRICK WALL ANCHOR:HILTI HIT HY 20 ADHESIVE ANCHOR SIZE:Ø = 3/8" EMBEDMENT:2" SPACING:S = 24" (MAX) 4.HOLLOW, UNGROUTED CMU WALL & BRICK WALL WITH HOLES ANCHOR:HILTI HIT HY 20 ADHESIVE ANCHOR SIZE:Ø = 3/8" EMBEDMENT:THROUGH FACE OF HOLLOW BASE > 6" (MIN) SPACING:S = (2) COMPLETE BRICKS IN ANY DIRECTION (1) ANCHOR PER BLOCK CELL (CMU) 5. STEEL BOLT:A325 BOLT SIZE:Ø = 1/2" BOLT HOLE SIZE:Ø = 9/16" 6.IF THE WALL MATERIAL IS DIFFERENT FROM ABOVE, CONTRACTOR SHALL INFORM DESIGN ENGINEER IMMEDIATELY. 7.ALL HARDWARE AND PARTS SHALL BE HOT-DIPPED GALVANIZED WITH LOCK WASHERS AND HEAVY HEX NUTS. 8.ALL BOLT HOLES SHALL BE 7/16"Ø UNLESS NOTED OTHERWISE. 9.THE MAX LOAD BETWEEN ANCHORS SHALL BE LESS THAN 400 POUNDS. UNISTRUT MOUNTING BRACKET P/N P3000HS WITH P1012S CHANNEL NUTS OR EQUIVALENT (TYP) AT&T RRH MOUNTING PLATE BOLT UNISTRUT TO WALL AT 2'-0" O.C. SPACING (SEE NOTES) KATHREIN 800 10992 DIMENSION (H x W x D) WEIGHT, W/ CLAMPS 105.2" x 20" x 6.9" 144.3 lbs 20" 10 5 . 2 " 6. 9 " 2-3/8" (O.D.), SCH. 80 ANTENNA MOUNTING PIPE (OR PER STRUCTURAL) ANTENNA DOWNTILT MOUNTING BRACKET, SUPPLIED W/ ANTENNA (TYP) PROPOSED ANTENNA ANTENNA MOUNTING BRACKET, SUPPLIED W/ ANTENNA (TYP) RRH MOUNTING BRACKET SUPPLIED W/RRH (TYP.) RRH PER PLAN MOUNTING PIPE EQUIPMENT DETAILS PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: R-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology MOUNT DETAIL PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: R-2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology V1 3 TYPE VV TYPE GT TYPE TA TYPE GY TYPE GR TYPE VN TYPE NC TYPE VS TYPE VB TYPE SS TYPE PT NOTE: ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. TYPE 2-YA-2 TYPE XA TYPE YA-2TYPE HS 0. 0 0 0 " 0. 5 0 0 " 1. 5 0 0 " 2. 5 0 0 " 3. 5 0 0 " 4. 5 0 0 " 5. 5 0 0 " 6. 5 0 0 " 7. 5 0 0 " 8. 5 0 0 " 9. 5 0 0 " 10 . 5 0 0 " 10 . 5 0 0 " 10 . 5 0 0 " 0.500" 1.250" 2.000" 2.875" 3.500" 1.125" 0.000" 4.000" 56.20 (4) 437.00 (26) NO.4150A414 INSULATION NO.WBKT1 WALL BRACKET 3 AWG GROUNDING CONDUCTOR TO GROUND RING #6 AWG GROUNDING CABLE (PROVIDED WITH KIT) GPS UNIT GROUNDING KIT 1/2" COAX CABLE 8" MIN. BENDING RADIUS PER MANUFACTURER'S STANDARD TO GROUNDING SYSTEM GROUNDING BUS BAR #2 AWG BARE TINNED COPPER NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND TX RX FROM ANTENNA JUMPER (TYP) APPROVED GROUNDING KIT (TYP) ANTENNA CABLE TRAY TO CABLE TRAY (TYP) RX FROM ANTENNA FRAME SUPPORT #2 AWG BCW BONDED TO GROUND WIRE ALONG CABLE TRAY #6 AWG #2 AWG BCW GROUNDING BAR MOUNTED NEAR ANTENNAS APPROVED WEATHERPROOFING KIT (TYP) TYPICAL GROUNDING SCHEMATIC 4SCALE N.T.S.1SCALE N.T.S. 5SCALE N.T.S.2SCALE N.T.S. 7 6SCALE N.T.S.3SCALE N.T.S. EXOTHERMIC WELDING 12" & 18" GROUND BARS GPS GROUNDING DETAIL COAX GROUNDING DETAIL MECHANICAL LUG CONNECTIONSCALE N.T.S. NOTES: 1.ALL HARDWARE BOLT, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER, GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. 2.COPPER SHIELD, ANTIOX, CR NO-OX OR EQUIVALENT SHALL BE PLACED WHERE ALL DISSIMILAR METALS CONNECT. 3.ALL LUGS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4.ALL RRH GROUND WIRES SHALL BE #2 GREEN STRANDED. 5.ALL GROUND LUGS SHALL BE 2-HOLE, LONG BARREL. 6.OUTDOOR GROUND LUGS SHALL BE BLACK HEAT SHRINK W/O INSPECTION HOLES. 7.INDOOR GROUND LUGS SHALL BE CLEAR HEAT SHRINK W/ INSPECTION HOLES. WIRE SIZE BURNDY LUG BOLT SIZE #2 AWG SOLID TINNED #2/0 AWG STRANDED #4/0 AWG STRANDED #2 AWG STRANDED YA3C-2TC38 YA2C-2TC38 YA26-2TC38 YA28-2N 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT BURNDY TWO HOLE LUG W/ LONG BARREL FOR #2 AWG STRANDED OR EQUIVALENT BARE WIRE TO BE NO-0X AT BOTH ENDS #2 AWG STRANDED GREEN INSULATION HEAT SHRINK (CLEAR) BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) NUT (TYP) LOCK WASHER (TYP) GROUND BAR BOLT (TYP) GROUNDING CONDUCTOR RRH GROUNDING DETAILS (TYP) PROPOSED #2 AWG GROUND FROM NEW RRH UNIT TO EXISTING GROUND BAR (OR PER MANUFACTURER) TO GROUND BAR PROPOSED RRH UNIT ANTENNA LEVEL EXISTING GROUND BAR EXISTING #2 AWG GROUND LEADS (GC TO FIELD VERIFY) NOTES: 1.ENSURE THAT ALL SECTORS ARE GROUNDED PROPERLY TO CURRENT AT&T STANDARDS #2 AWG GREEN INSULATED STRANDED COPPER WIRE FROM GROUND BAR TO ALL RRH UNITS OR MORE PER MANUFACTURER TYPICAL ANTENNA TELECT Raycap Raycap RaycapRaycapRaycapRaycap Raycap Raycap RaycapRaycapRaycapRaycap ---BUS BAR #2 AWG GREEN INSULATED STRANDED COPPER WIRE FROM GROUND BAR TO ALL SURGE SUPPRESSORS GROUND LEVEL PROPOSED #6 AWG STRANDED COPPER CONDUCTOR WITH GREEN, 600V, THWN-2 INSULATION, GROUNDED TO GROUND BAR WITH 2-HOLE COMPRESSION LUG NEW AIRSCALE SLOT (LOCATE BY AT&T CM) --- EXISTING SITE EQUIPMENT (GENERIC SITE SHOWN) RAYCAP DC6 TYPICAL RRH MOUNT PIPE GROUNDING DETAILS PO BOX 2621, BOISE, ID 83701 P: 530.539.4787 E: CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 02/20/19 ISSUED FOR CONSTRUCTION JCM SHEET TITLE: SHEET NUMBER: G-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 164 WEST 1ST NORTH REXBURG, IDAHO 83440 LTE 5C REXBURG STEINER ELEVATOR IDL04328 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology