HomeMy WebLinkAboutBUILDING REVIEW - 17-00799 - 485 N 2nd E #105 - The Hickory - Commercial Tenant RemodelReview
Report
Current Building Review Status: REVISIONS
Application Number: 17-00799Permit Details
Application Received Date: 12/29/2017
Commercial Tenant Finish
Application Approved Date:
Application Approved Status: ACCEPTED
12/29/2017
485 N 2nd E #104 & #105
The Hickory - Commercial Tenant Remodel
Status of Plan Reviews Completed
01/02/2018Electrical Review COMPLETED
01/08/2018HVAC Review COMPLETED
01/08/2018Plumbing Review COMPLETED
01/10/2018Building Review REVISIONS
Permit Review Status
Plan Reviews Still in Progress
DESCRIPTION COMMENTS STA TUS
*Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed!
Occupant load is identified on plans as per IBC
Section 1004
REVISIONSOccupant load looks to be between 150 and 200
(seating in dining is 160 alone). For review
purpose, occupants for bench seating based on
24" min. per person.
*Revisions Response :
Doors meet the requirements of IBC Section
1008
REVISIONSInterior egress door at back vestibule is shown
swinging the wrong direction.
*Revisions Response :
Exit Access meets the requirements of IBC
Section 1014
REVISIONSInclude exit signage for required 2nd exit shown
on code analysis page (provide directional
indicators for both directions on sign near bar
and add exit sign over door into back vestibule).
*Revisions Response :
Fire partitions meet the requirements of IBC
Section 708
N/A
Building height and area meets the requirements
of IBC Section 500 & Table 503
Based on adding an A occupancy (with 50 or
more occupants) AND as non-separated mixed
occupancy building the new allowed area for
Type V-B construction is 24,000 sf in a one
story building with NFPA 13 system (6,000 +
(6,000x3)). The actual area of the building is
18,801 per original plans.
COMPLETED
Reviewed By: Quinton Owens
Review Date: 01/10/2018
Plan Review Details
quinton.owens@rexburg.org
Building Review Status: REVISIONS
Page 1 of 2
Approval of plans does not constitute approval of variance from code
Building Review (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Type of construction is identified on plans.* V-A construction noted on plans. The building
does not have fire protective rating for roof
structure.
* Building shall be considered V-B construction,
NOT V-A
COMPLETED
fireblocking and draftstopping meet the
requirements of IBC Section 718
All fire blocking will be inspected for approval
per IBC 718
COMPLETED
Panic Hardware shall be installed as per IBC
Section 1008.1.10
Doors serving assembly space shall have panic
hardware (except as allowed on main exit per
IBC 1008.1.9.3, item 2)
COMPLETED
Building complies with IECC (IBC, 1301)Existing structure.COMPLETED
Page 2 of 2
Approval of plans does not constitute approval of variance from code
J J
JJ
JJ
J
J
JJ
J
J
J
JJ J
J JJ
J
J
J
J
J
J J
J
J
J
J
J
J
J
J
JJJJ
J
J
J
J
J
J
J
J J
J
JJ
J
J
S
CD
6
S
CD
6
3
3
3
4
W
D
1
W
D
1
S
CD
6
3
4
2
3
4
J H G F
SE
A
T
I
N
G
12
7
RE
C
E
P
T
I
O
N
10
2
CI
R
C
U
L
A
T
I
O
N
11
8
PR
E
P
11
3
KI
T
C
H
E
N
11
1
CI
R
C
U
L
A
T
I
O
N
10
9
.
1
WA
L
K
-
I
N
F
R
I
G
E
.
11
0
DI
S
H
W
A
S
H
10
6
FR
E
E
Z
E
R
10
5
EM
P
L
O
Y
E
E
R
E
S
T
R
O
O
M
10
7
EL
E
C
T
R
I
C
A
L
10
4
VE
S
T
I
B
U
L
E
10
3
BA
R
A
R
E
A
10
9
ST
O
R
A
G
E
10
8
ME
C
H
11
7
WO
M
E
N
'
S
11
5
ME
N
'
S
11
6
SE
R
V
E
R
S
T
A
T
I
O
N
11
4
SE
A
T
I
N
G
12
2
SE
A
T
I
N
G
13
1
SE
A
T
I
N
G
13
3
F1
F1
F1
F1
F2
F2
F2
F2
F2
F2
F2
F2
(T
Y
P
)
F3
F3
E F3
E
F3
E
F3
E
F3
E
F3
E
(T
Y
P
)
F3
(T
Y
P
)
F3
F4
F4
F4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
11
1
1
1
1
1
1
1
11
1
1
1
1
1
1
1 1
1
1
1
1
1
1
1
1
1
11
1
1
1 1
1
1
'L
B
'
LB
-
2
9
LB
-
3
1
LB
-
3
3
LB
-
3
5
1
1
1
F1
1
TEE BAR GRIDPOWER SUPPLY CONDUIT FOR CEILING OR WALL "J" BOX.
SU
P
P
O
R
T
W
I
R
E
B
Y
E
L
E
C
T
R
I
C
A
L
C
O
N
T
R
A
C
T
O
R
IN
D
E
P
E
N
D
E
N
T
O
F
C
E
I
L
I
N
G
S
Y
S
T
E
M
.
(
T
Y
P
I
C
A
L
)
AC
O
U
S
T
I
C
C
E
I
L
I
N
G
TI
L
E
SU
P
P
O
R
T
C
L
I
P
S
AL
L
S
I
D
E
S
AC BALLAST
E
M
E
R
G
E
N
C
Y
B
A
L
L
A
S
T
WA
L
L
SW
I
T
C
H
HO
T
W
H
T
/
R
E
D
B
L
K
OR
BL
K
1
2
0
V
OR
G
2
7
7
TE
S
T
SW
I
T
C
H
N.
C
.
B
L
K
IN
V
E
R
T
E
R
CO
N
N
E
C
T
O
R
CH
A
R
G
I
N
G
IN
D
I
C
A
T
O
R
RE
D
WH
T
VL
T
BR
N
CO
M
M
O
N
W
H
I
T
E
WH
T
/
B
L
K
WHITEBLACKREDBLUELAMP 2 BLUE BLUEBRNREDYLWYLW/BLKBRNWARNING:SPECIFICATIONSREFER TO MANUFACTURERS LAMP 1 EMERGENCY FUNCTION BLU/WHT
NO
T
E
:
C
O
N
S
U
L
T
T
H
E
M
A
N
U
F
A
C
T
U
R
E
R
S
D
OC
U
M
E
N
T
A
T
I
O
N
F
O
R
E
X
A
C
T
W
I
R
I
N
G
D
IAGRAMS.ORIGINAL SIGNED BY:SHAWN A. MEADOR DATE ORIGINAL SIGNED:ON FILE AT:PAYNE ENGINEERING INC.13053 S T A T E O F I D AHO S HA W N A .M E A D ORREGISTEREDRPOFESSIONALENGINEER Engineering Inc.Consulting Engineers 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 www.payneengineeringinc.commethodstudioinc.9 2 5 s o u t h w e s t t e m p l e s a l t l a k e c i t y , u t a h 8 4 1 0 1 p h o n e : (8 0 1) 5 3 2 - 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project:
E d c b a
E d c b a
12
3
4
5
6
12
3
4
5
6
P.E. JOB #176912/19/2017 E1.0FLOOR PLAN -LIGHITNG16.0500 12/19/2017Rexburg, IdahoHickory Restaurant T.I.@ Teton River ‐ Bldg. #1 PERMIT SETKEY NOTES:#
8'
4'
0"
A.
C
O
O
R
D
I
N
A
T
E
L
I
G
H
T
F
I
X
T
U
R
E
L
OCATION WITH CEILING PLAN,MECHANICAL GRILLES, DIFFUSERS, SOUND SPEAKERS, ETC. LOCATE ALL LIGHT FIXTURES IN MECHANICA L EQUIPMENT ROOMS AFTER ALL EQUIPMENT HAS BEEN INSTALLED.B.
J
U
N
C
T
I
O
N
B
O
X
E
S
F
O
R
L
I
G
H
T
I
N
G
C
I
R
C
U
I
T
I
N
G
A
R
E
N
O
T
S
H
O
W
N
F
O
R
CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED F OR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTE D FOR "THROUGH-BRANCH CIRCUIT WIRING".C.
I
N
S
T
A
L
L
A
L
L
L
I
G
H
T
F
I
X
T
U
R
E
S
I
N
MECHANICAL ROOMS, AFTER ALL MECHANICAL EQUIPMENT IS IN PL ACE. ADJUST AS NECESSARY TO MISS PIPING, DUCTS, FILTER A CCESS PANELS, ETC. PROVIDE FIXTURES WITH CHAIN SUSPENSION KITS AS REQUIRED TO SUSPEND BELOW DUCTS, IF REQUIRED.D.
V
E
R
I
F
Y
C
O
M
P
A
T
I
B
I
L
I
T
Y
O
F
A
L
L
F
I
X
T
U
R
E
L
A
M
P
S
W
I
T
H
F
I
X
T
U
R
E
S
PRIOR TO ORDERING.E.
V
E
R
I
F
Y
V
O
L
T
A
G
E
W
I
T
H
N
E
W
L
I
GHTING EQUIPMENT PRIOR TO ORDERING.GENERAL NOTES:
SC
A
L
E
:
1
/
4
"
=
1
'
-
0
"
1
FL
O
O
R
P
L
A
N
-
L
I
G
H
T
I
N
G
P
L
A
N
1
E
.
C
.
S
H
A
L
L
P
R
O
V
I
D
E
P
O
W
E
R
,
C
O
N
TROLS,ROUGH-IN AND ETC. FOR OWNER PROVIDED, CONTRACTOR I NSTALLED LIGHT FIXTURE(S).E.C. SHALL COORDINATE WITH OWNER FOR EXACT LAYOUT,CONTROLS AND CONNECTION RE QUIREMENTS FOR FIXTURE(S).CONTROLS SHALL MEET THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE REQUIREMEN TS AND TOTAL LIGHTING LOAD OF THE SPACE SHALL NOT EXCEED 1.6 WATTS/SQFT.LIGHTING FIXTURE SCHEDULE
TY
P
E
F
I
X
T
U
R
E
D
E
S
C
R
I
P
T
I
O
N
M
O
U
N
T
I
N
G
V
O
L
T
S
L
A
M
P
S
M
F
G
R
.
C
A
T
A
L
O
G
#
N
O
T
E
S
F1
B
A
T
T
E
R
Y
E
X
I
T
SI
G
N
,
T
H
E
R
M
O
P
L
A
S
T
I
C
,
G
R
E
E
N
LE
D
,
S
I
N
G
L
E
/
D
O
U
B
L
E
F
A
C
E
WA
L
L
O
R
C
E
I
L
I
N
G
1
2
0
-
2
7
7
W
I
T
H
F
I
X
T
U
R
E
L
I
T
H
O
N
I
A
L
Q
M
-
S
-
3
-
R
-
1
2
0
/
2
7
7
-
E
L
N
F2
W
A
L
L
/
C
E
I
L
I
N
G
M
O
U
N
T
E
D
L
E
D
EM
E
R
G
E
N
C
Y
L
I
G
H
T
WA
L
L
O
R
C
E
I
L
I
N
G
1
2
0
-
2
7
7
W
I
T
H
F
I
X
T
U
R
E
L
I
T
H
O
N
I
A
E
L
M
2
-
L
E
D
F3
2
X
2
L
A
Y
-
I
N
G
R
I
D
T
R
O
F
F
E
R
R
E
C
E
S
S
E
D
1
2
0
-
2
7
7
L
E
D
-
4
0
0
0
L
M
-
4
0
0
0
K
L
I
T
H
O
N
I
A
2
T
L
2
-
4
0
L
-
F
W
-
A
1
2
-
E
Z
1
-
L
P
8
4
0
F3
E
2
X
2
L
A
Y
-
I
N
G
R
I
D
T
R
O
F
F
E
R
,
W
/
EM
E
R
G
.
B
A
T
T
E
R
Y
P
A
C
K
RE
C
E
S
S
E
D
1
2
0
-
2
7
7
L
E
D
-
4
0
0
0
L
M
-
4
0
0
0
K
L
I
T
H
O
N
I
A
2
T
L
2
-
4
0
L
-
F
W
-
A
1
2
-
E
Z
1
-
L
P
8
4
0-EL14L
F4
4
F
T
,
L
E
D
S
T
R
I
P
,
C
H
A
I
N
H
A
N
G
E
R
S
SU
R
F
A
C
E
/
S
U
S
P
E
N
D
E
D
1
2
0
/
2
7
7
L
E
D
-
3
0
0
0
LM-4000K
L
I
T
H
O
N
I
A
Z
L
2
N
-
L
4
6
-
3
0
0
0
L
M
-
M
D
D
-
1
2
0
-
4
0
K
-
8
0
C
R
I
-
Z
A
C
V
H
LIGHTING OCCUPANCY SENSOR SCHEDULE
TY
P
E
M
F
G
R
.
C
A
T
A
L
O
G
#
D
E
S
C
R
I
P
T
I
O
N
N
O
T
E
S
A
P
P
R
O
V
E
D
E
Q
U
A
L
S
CE
I
L
I
N
G
S
E
N
S
O
R
S
CD
6
S
E
N
S
O
R
S
W
I
T
C
H
C
M
R
P
D
T
9
D
U
A
L
-
TECHNOLOGY, LINE VOLTAGE, SMALL
MO
T
I
O
N
8
0
0
W
M
A
X
L
O
A
D
WATTSTOPPER, HUBBELL
WA
L
L
S
E
N
S
O
R
S
WD
1
S
E
N
S
O
R
S
W
I
T
C
H
W
S
X
P
D
T
-
S
A
-
*
*
-
D
U
AL-TECHNOLOGY, 1-POLE, NEUTRAL
RE
Q
U
I
R
E
D
COLOR TO MATCH WIRING DEVICES
H
U
B
B
E
L
L
,
W
A
T
T
S
T
O
P
P
E
R
SC
A
L
E
:
N
O
N
E
A
RE
C
E
S
S
E
D
L
I
G
H
T
F
I
X
T
U
R
E
D
E
T
A
I
L
SC
A
L
E
:
N
O
N
E
B
EM
E
R
G
.
B
A
T
T
E
R
Y
P
A
C
K
W
I
R
I
N
G
1
C
I
T
Y
C
O
M
M
E
N
T
S
0
1
/
1
2
/
1
8
J
J
JJ
MM
M
M
G
24
7
2
24
7
2
2472
D DD
D
18
7
2
D
H
D
18
7
2
18
7
2
18
4
8
2
3
4
J H G F
SE
A
T
I
N
G
12
7
RE
C
E
P
T
I
O
N
10
2
CI
R
C
U
L
A
T
I
O
N
11
8
PR
E
P
11
3
KI
T
C
H
E
N
11
1
CI
R
C
U
L
A
T
I
O
N
10
9
.
1
WA
L
K
-
I
N
F
R
I
G
E
.
11
0
DI
S
H
W
A
S
H
10
6
FR
E
E
Z
E
R
10
5
EM
P
L
O
Y
E
E
R
E
S
T
R
O
O
M
10
7
EL
E
C
T
R
I
C
A
L
10
4
VE
S
T
I
B
U
L
E
10
3
BA
R
A
R
E
A
10
9
ST
O
R
A
G
E
10
8
ME
C
H
11
7
WO
M
E
N
'
S
11
5
ME
N
'
S
11
6
SE
R
V
E
R
S
T
A
T
I
O
N
11
4
SE
A
T
I
N
G
12
2
SE
A
T
I
N
G
13
1
SE
A
T
I
N
G
13
3
1111111
LB
-
9
LB
-
7
ACAC
AC
2 2
3
3
33
4
4
'L
B
'
LB
-
1
7
LB
-
1
7
LB
-
1
1
LB
-
1
5
LB
-
1
3
LB
-
1
9
LB
-
1
8
LB
-
2
1
LB
-
2
3
LB
-
2
0
LB
-
2
2
'L
C
'
8
44
54
3
13
18
21
22
23
24
26
27
29
33 34
37
44
b
44
a
56
.
1
56
.
2
56
.
3
57
6059
LC
-
4
2
54
(O
N
R
O
O
F
)
EF
-
1
(O
N
R
O
O
F
)
EF
-
2
(O
N
R
O
O
F
)
EF
-
3
(O
N
R
O
O
F
)
MA
U
-
1
5
5
1
1
5
1
EN
T
R
A
N
C
E
CO
N
D
U
I
T
(
S
)
4"
S
Q
U
A
R
E
BO
X
RA
I
S
E
D
R
I
N
G
TO
S
U
I
T
W
A
L
L
RECEPTACLE - 20AMP RATED - SEE SPECIFICATIONS.NORMAL POWER COLOR - (SEE SPEC'S)COVER PLATE - STYLE & COLOR TO BE AS PER SPECIFICATIONS.CIRCUIT NUMBER TO BE WRITTEN ON BACK OF COVER W/FELT-TIP MARKER
GR
E
E
N
I
N
S
U
L
A
T
E
D
GR
O
U
N
D
C
O
N
D
U
C
T
O
R
ORIGINAL SIGNED BY:SHAWN A. MEADOR DATE ORIGINAL SIGNED:ON FILE AT:PAYNE ENGINEERING INC.13053 S T A T E O F I D AHO S HA W N A .M E A D ORREGISTEREDRPOFESSIONALENGINEER Engineering Inc.Consulting Engineers 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 www.payneengineeringinc.commethodstudioinc.9 2 5 s o u t h w e s t t e m p l e s a l t l a k e c i t y , u t a h 8 4 1 0 1 p h o n e : (8 0 1) 5 3 2 - 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project:
E d c b a
E d c b a
12
3
4
5
6
12
3
4
5
6
P.E. JOB #176912/19/2017 E2.0FLOOR PLAN -POWER16.0500 12/19/2017Rexburg, IdahoHickory Restaurant T.I.@ Teton River ‐ Bldg. #1 PERMIT SET
A.
E
V
E
N
I
F
S
P
E
C
I
F
I
C
A
L
L
Y
I
N
D
I
C
A
T
E
D
O
N
T
H
E
D
R
A
W
I
N
G
S
,
A
L
L
D
E
V
I
C
E
S
SH
O
W
N
A
T
O
R
N
E
A
R
M
I
L
L
W
O
R
K
/
C
A
S
E
W
O
R
K
S
H
A
L
L
B
E
C
O
O
R
D
I
N
A
T
E
D
WI
T
H
T
H
E
A
R
C
H
I
T
E
C
T
U
R
A
L
E
L
E
V
A
T
I
O
N
D
R
A
W
I
N
G
S
A
N
D
M
I
L
L
W
O
R
K
IN
S
T
A
L
L
E
R
T
O
I
N
S
U
R
E
P
R
O
P
E
R
M
O
UNTING HEIGHTS. CONTRACTOR
SH
A
L
L
A
D
J
U
S
T
D
E
V
I
C
E
S
A
S
N
E
C
E
S
S
A
R
Y
I
N
O
R
D
E
R
T
O
P
O
S
I
T
I
O
N
DE
V
I
C
E
S
S
U
C
H
T
H
A
T
T
H
E
Y
W
I
LL NOT FALL BEHIND MILLWORK,
CA
B
I
N
E
T
S
O
R
B
E
D
I
R
E
C
T
L
Y
A
B
OVE SINKS OR MIDWAY BETWEEN
TI
L
E
W
O
R
K
/
W
A
L
L
O
R
W
A
I
N
S
C
O
A
T
I
N
G
,
E
T
C
.
B.
I
T
S
H
A
L
L
B
E
T
H
E
R
E
S
P
O
N
S
I
B
I
L
I
T
Y
O
F
T
H
E
C
O
N
T
R
A
C
T
O
R
T
O
I
N
S
T
A
L
L
A
G
F
C
I
T
Y
P
E
R
E
C
E
P
T
A
C
L
E
F
O
R
A
L
L
R
E
C
P
T
A
C
L
E
S
S
H
O
W
N
I
N
T
O
I
L
E
T
RM
S
,
B
A
T
H
R
O
O
M
S
,
K
I
T
C
H
E
N
S
/
S
E
R
V
I
N
G
A
R
E
A
S
,
R
O
O
F
T
O
P
,
OU
T
D
O
O
R
S
O
R
W
I
T
H
I
N
6
F
T
O
F
A
N
Y
S
I
N
K
,
B
A
S
I
N
,
T
U
B
O
R
F
L
O
O
R
S
I
N
K
AN
D
A
L
L
O
T
H
E
R
A
R
E
A
S
D
E
F
I
N
E
D
B
Y
T
H
E
N
E
C
.
W
H
E
T
H
E
R
SP
E
C
I
F
I
C
A
L
L
Y
I
N
D
I
C
A
T
E
D
O
N
T
H
E
D
R
A
W
I
N
G
S
O
R
N
O
T
.
GE
N
E
R
A
L
N
O
T
E
S
:
K
E
Y
N
O
T
E
S
:
#
SC
A
L
E
:
1
/
4
"
=
1
'
-
0
"
1
FL
O
O
R
P
L
A
N
-
P
O
W
E
R
8'
4'
0"
SC
A
L
E
:
N
O
N
E
A
RE
C
E
P
T
A
C
L
E
M
O
U
N
T
I
N
G
D
E
T
A
I
L
NO
T
E
S
:
1.
E
.
C
.
S
H
A
L
L
P
R
O
V
I
D
E
A
L
L
R
E
Q
U
I
R
ED
C
O
N
N
E
C
T
I
O
N
S
A
N
D
I
N
T
E
R
L
O
C
K
S
B
ETWEEN KITCHEN HOOD CONTROL PANEL , ROOFTOP EXHAUST AND MAKE-UP
AI
R
F
A
N
S
,
H
O
O
D
L
I
G
H
T
I
N
G
,
G
A
S
S
HU
T
-
O
F
F
V
A
L
V
E
A
N
D
S
H
U
N
T
-
T
R
I
P
B
R
E
A
KERS OF EQUIPMENT LOCATED UNDER HOOD. COORDINATE WITH CAPTIVE
AI
R
E
S
H
O
P
D
R
A
W
I
N
G
S
.
2.
E
Q
U
I
P
M
E
N
T
S
H
A
L
L
B
E
S
UP
P
L
I
E
D
T
H
R
O
U
G
H
S
H
U
N
T
-
T
R
I
P
B
R
E
A
K
E
R
,
B
R
E
A
KER SHALL BE CONTROLLED VIA KIT CHEN HOOD ANSUL SYSTEM; E.C. SHA LL
PR
O
V
I
D
E
A
L
L
R
E
Q
U
I
R
E
D
C
O
N
N
E
C
T
I
O
N
S
,
I
N
T
E
R
L
O
C
K
S
A
N
D
E
T
C
.
3.
P
R
O
V
I
D
E
L
O
C
A
L
D
I
S
C
O
N
N
E
C
T
I
N
G
M
EA
N
S
;
F
U
S
E
P
E
R
E
Q
U
I
P
M
E
N
T
N
A
M
E
P
L
ATE RATING.
4.
F
A
N
S
H
A
L
L
B
E
C
O
N
T
R
O
L
L
E
D
T
H
R
O
U
G
H
K
I
T
C
H
E
N
H
O
O
D
C
O
N
T
R
O
L
P
A
N
E
L
;
COORDINATE WITH KITCHEN EQUIPM ENT SUPPLIER AND KITCHEN HOOD
SH
O
P
D
R
A
W
I
N
G
S
F
O
R
A
L
L
R
E
Q
U
I
R
E
D
C
ON
N
E
C
T
I
O
N
S
A
N
D
I
N
T
E
R
L
O
C
K
S
B
Y
E
.
C.
5.
P
R
O
V
I
D
E
1
2
0
V
P
O
W
E
R
T
O
F
A
C
T
O
R
Y
MO
U
N
T
E
D
C
O
N
V
E
N
I
E
N
C
E
O
U
T
L
E
T
F
R
O
M NEAREST RECEPTACLE CIRCUIT.
GE
N
E
R
A
L
N
O
T
E
S
:
A.
R
E
F
E
R
T
O
K
I
T
C
H
E
N
C
O
N
S
U
L
T
A
N
T
D
R
A
WI
N
G
S
F
O
R
A
D
D
I
T
I
O
N
A
L
I
N
F
O
R
M
A
T
I
ON AND ELECTRICAL REQUIREMENTS.KITCHEN EQUIP. SCHEDULE
IT
E
M
#
E
Q
U
I
P
M
E
N
T
D
E
S
C
R
I
P
T
I
O
N
V
O
L
T
S
PH.
A
M
P
S
H
P
P
A
N
E
L
C
I
R
C
U
I
T
F
E
E
D
E
R
C
O
N
N
ECTION TYPE
N
O
T
E
S
3
M
E
A
T
S
L
I
C
E
R
1
2
0
V
1
4
A
-
L
C
3
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
8
D
I
S
H
W
A
S
H
E
R
1
2
0
V
1
1
1
A
3
/
4
L
C
5
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
D
I
R
E
C
T
13
F
R
E
N
C
H
F
R
Y
W
A
R
M
E
R
1
2
0
V
1
8
A
-
L
C
1
6
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0P
2
18
R
E
A
C
H
-
I
N
F
R
E
E
Z
E
R
1
2
0
V
1
6
A
-
L
C
3
1
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
21
F
R
E
N
C
H
F
R
Y
W
A
R
M
E
R
1
2
0
V
1
8
A
-
L
C
2
0
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0P
2
22
S
A
N
D
W
I
C
H
/
S
A
L
A
D
P
R
E
P
1
2
0
V
1
7
A
-
L
C
3
1
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-20P
23
R
E
F
R
I
G
E
R
A
T
O
R
B
A
S
E
1
2
0
V
1
8
A
-
L
C
2
4
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0P
2
24
G
A
S
G
R
I
D
D
L
E
1
2
0
V
1
1
A
-
L
C
2
4
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
2
26
E
L
E
C
T
R
I
C
G
R
I
D
D
L
E
2
0
8
V
3
4
0
A
-
L
C
8
,
1
0
,
1
2
3
/
4
"
C
.
,
3
#
8
+
1
#
1
0
G
C
O
R
D
/
P
L
U
G
2
27
E
L
E
C
T
R
I
C
S
E
R
V
I
C
E
CO
U
N
T
E
R
20
8
V
1
1
8
A
-
L
C
2
8
,
3
0
3
/
4
"
C
.
,
2
#
1
0
+
1
#
1
0
G
C
O
R
D
/
P
L
U
G
L
6
-
3
0
29
P
R
O
O
F
E
R
C
A
B
I
N
E
T
1
2
0
V
1
1
5
A
-
L
C
1
9
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
33
D
I
S
P
L
A
Y
C
A
S
E
1
2
0
V
1
1
1
A
-
L
C
2
7
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
34
D
I
S
P
L
A
Y
C
A
S
E
1
2
0
V
1
1
1
A
-
L
C
2
5
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
37
S
A
N
D
W
I
C
H
/
S
A
L
A
D
P
R
E
P
1
2
0
V
1
7
A
-
L
C
3
3
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-20P
44
P
L
A
N
E
T
A
R
Y
M
I
X
E
R
1
2
0
V
1
1
5
A
3
/
4
L
C
1
7
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
20P
44
a
C
O
N
V
E
C
T
I
O
N
O
V
E
N
T
O
P
2
0
8
V
1
5
8
A
-
L
C
3
5
,
3
7
1
1
/
4
"
C
.
,
2
#
4
+
1
#
8
G
D
I
R
E
C
T
44
b
C
O
N
V
E
C
T
I
O
N
O
V
E
N
B
O
T
T
O
M
2
0
8
V
1
5
8
A
-
L
C
3
9
,
4
1
1
1
/
4
"
C
.
,
2
#
4
+
1
#
8
G
D
I
RECT
54
K
I
T
C
H
E
N
H
O
O
D
C
O
N
T
R
O
L
PA
N
E
L
12
0
V
1
5
A
-
L
C
1
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
D
I
R
E
C
T
1
56
.
1
F
O
O
D
P
A
N
WA
R
M
E
R
/
C
O
O
K
E
R
12
0
V
1
1
0
A
-
L
C
3
2
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
56
.
2
F
O
O
D
P
A
N
WA
R
M
E
R
/
C
O
O
K
E
R
12
0
V
1
1
0
A
-
L
C
3
4
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
56
.
3
F
O
O
D
P
A
N
WA
R
M
E
R
/
C
O
O
K
E
R
12
0
V
1
1
0
A
-
L
C
3
6
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
57
P
A
N
I
N
I
G
R
I
L
L
1
2
0
V
1
1
2
A
-
L
C
2
1
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5
-
2
0
P
59
S
A
N
D
W
I
C
H
/
S
A
L
A
D
P
R
E
P
1
2
0
V
1
1
2
A
-
L
C
2
3
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5-20P
60
S
A
N
D
W
I
C
H
/
S
A
L
A
D
P
R
E
P
1
2
0
V
1
1
2
A
-
L
C
2
9
3
/
4
"
C
.
,
2
#
1
2
+
1
#
1
2
G
C
O
R
D
/
P
L
U
G
5-20P KITCHEN HOOD FAN SCHEDULE
ID
#
V
O
L
T
S
P
H
.
H
P
P
A
N
E
L
C
I
R
C
U
I
T
F
E
E
D
E
R
DISCONNECT SIZE
D
I
S
C
O
N
N
E
C
T
T
Y
P
E
N
O
T
E
S
EF
1
2
0
8
V
3
1
-
1
/
2
L
B
2
6
,
2
8
,
3
0
3
/
4
"
C
.
,
3
#
1
2
+
1
#
1
2
G
3
0
A
F
U
S
E
D
/
N
E
M
A
3
R
3
,
4
,
5
EF
2
2
0
8
V
3
2
L
B
2
6
,
2
8
,
3
0
3
/
4
"
C
.
,
3
#
1
2
+
1
#
1
2
G
3
0
A
F
U
S
E
D
/
N
E
M
A
3
R
3
,
4
,
5
EF
3
2
0
8
V
3
1
/
2
L
B
3
2
,
3
4
,
3
6
3
/
4
"
C
.
,
3
#
1
2
+
1
#
1
2
G
3
0
A
F
U
S
E
D
/
N
E
M
A
3
R
3
,
4
,
5
MA
U
1
2
0
8
V
3
5
L
B
3
8
,
4
0
,
4
2
3
/
4
"
C
.
,
3
#
1
0
+
1
#
1
0
G
3
0
A
F
U
S
E
D
/
N
E
M
A
3
R
3
,
4
,
5
1
I
N
S
T
A
L
L
S
H
O
W
W
I
N
D
O
W
R
E
C
E
P
T
ACLE AS REQUIRED BY NEC SECTION 210.62, MOUNT RECEP TACLE JUST ABOVE WINDOW.2
E
X
I
S
T
I
N
G
R
E
C
E
P
T
A
C
L
E
S
I
N
A
R
E
A
T
O
R
E
M
A
I
N
A
C
T
I
V
E
;
C
O
O
R
D
I
N
A
T
E
WITH OWNER.3
E
.
C
.
S
H
A
L
L
C
O
O
R
D
I
N
A
T
E
Q
T
Y
A
N
D
L
O
C
A
T
I
O
N
O
F
1
2
0
V
RECEPTACLES IN BAR & RECEPTION AREA WITH OWNER.4
E
X
I
S
T
I
N
G
F
R
E
E
Z
E
R
/
C
O
O
L
E
R
T
O
R
E
M
A
I
N
;
E
.
C
.
S
H
A
L
L
M
A
I
N
T
A
I
N
FUNCTIONALITY TO ASSOCIATED EQUIPMENT. COORDINATE WITH OWNER.5
A
L
L
1
2
0
V
O
L
T
G
E
N
E
R
A
L
P
U
R
P
O
S
E
C
O
N
V
E
N
I
E
N
C
E
O
U
T
L
E
T
S
I
N
KITCHEN AREA SHALL BE GFCI TYP E RECEPTACLES, AS PER CODE.SEE GENERAL NOTES THIS SHEET.1
C
I
T
Y
C
O
M
M
E
N
T
S
0
1
/
1
2
/
1
8
1