HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00093 - 565 Pioneer Rd - Rockcreek Townhomes #196Permit Inspection Summary Permit Status of (Open) as of Report Date: 03/27/2019 9:31 am Permit Details Permit Number: 17-00093 565 Pioneer Rd - Rockcreek Townhomes #196 565 Pioneer Rd Building - Single Family Residence Permit Issued Date: 03/29/2017 Permit Inspection Statistics 20Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 75.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 03/30/2017PassTed DyeResidential Footing Inspection 03/30/2017FailTed DyeSheeting Those Spots that the sheeting missed being nailed to the studs is marked with pink paint. * The 3" grid pattern that is required for portal frame designs, on both side of the garage door, through the osb., over the garage door header has not been done. Inspector Comments: 07/10/2017FailLarry BeesleySheeting There was some studs not nailed. They are marked with orange paint.Inspector Comments: 09/26/2017FailLarry BeesleyResidential Insulation Inspection inspection of insulation behind the bath tubs only. This one failed because one tub was insulated. Inspector Comments: 10/24/2017PassLarry BeesleySheeting Re- inspected sheeting with framing inspection. Corrections have been completed. Inspector Comments: 10/27/2017PassLarry BeesleyResidential Framing/Structure Inspection The framing is completed and ok to insulate.Inspector Comments: 10/27/2017PassLarry BeesleyResidential Insulation Inspection There are 2 baffle boards on front wall and 2 over bathroom on east wall. the insulation was installed behind the tub and shower to fix the earlier failed insulation inspection. FIX THE INSULATION BETWEEN THE TWO GARAGES SO IT WONT SAG OR FALL DOWN!! Inspector Comments: 11/27/2017PassLarry BeesleyResidential Sheetrock/Drywall Inspection You are good to tape.Inspector Comments: 12/18/2017N/ALarry BeesleyRadon-Ground Inspection Radon system has not been required on these unites.Inspector Comments: 01/26/2018FailTed DyeResidential Building Final 01/31/2018PassTed DyeFoundation Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 17-00093 565 Pioneer Rd - Rockcreek Townhomes #196 565 Pioneer Rd Building - Single Family Residence Permit Status of (Open) as of Report Date: 03/27/2019 9:31 am Permit Inspection Summary 05/10/2018PassTed DyeResidential Building Final Everything is completed on the unit and the landscaping for this 6 plex is completed. Thanks Inspector Comments: Electrical Inspection Type 10/25/2017PassBret StoddardResidential Electrical Rough-in 01/26/2018PassBret StoddardResidential Electrical Final Inspection Mechanical Inspection Type 10/25/2017PassDon AllenHVAC Rough-in 01/26/2018PassDon AllenHVAC Final Inspection Plumbing Inspection Type 10/25/2017PassDon AllenPlumbing Rough-in 01/26/2018PassDon AllenPlumbing Final Inspection 05/04/2018PassDon AllenPlumbing Water 05/04/2018PassDon AllenPlumbing Sewer Page 2 of 2